Detection of viruses directly from the fresh leaves of a Phalaenopsis orchid using a microfluidic system

被引:32
|
作者
Chang, Wen-Hsin [1 ]
Yang, Sung-Yi [1 ]
Lin, Chih-Lin [1 ]
Wang, Chih-Hung [1 ]
Li, Ping-Chen [4 ]
Chen, Tzong-Yueh [5 ]
Jan, Fuh-Jyh [4 ]
Lee, Gwo-Bin [2 ,3 ]
机构
[1] Natl Tsing Hua Univ, Dept Power Mech Engn, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Inst Biomed Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst Nanoengn & Microsyst, Hsinchu, Taiwan
[4] Natl Chung Hsing Univ, Dept Plant Pathol, Taichung 400, Taiwan
[5] Natl Cheng Kung Univ, Inst Biotechnol, Tainan, Taiwan
关键词
Microfluidics; Phalaenopsis orchid; Pathogen detection; Loop-mediated-isothermal-amplification; MEDIATED-ISOTHERMAL-AMPLIFICATION; ODONTOGLOSSUM RINGSPOT TOBAMOVIRUS; CYMBIDIUM MOSAIC POTEXVIRUS; QUANTITATIVE DETECTION; DIAGNOSTIC DEVICE; RAPID DETECTION; DNA; POINT; GENE; CARE;
D O I
10.1016/j.nano.2013.05.016
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Early detection of pathogens is crucial for the effective surveillance of diseases. Many efforts have been made to explore methods which can detect these pathogens within a short period of time without requiring a tedious protocol. However, these developed methods have disadvantages such as they are relatively time-consuming or require specialized laboratory facilities. In this work, we have developed an integrated microfluidic system for rapid and automatic detection of viruses by direct analysis from fresh Phalaenopsis orchid leaves. The entire protocol, including ribonucleic acid (RNA) purification, reverse transcription loop-mediated-isothermal-amplification (RT-LAMP) and optical detection by measuring changes in turbidity was performed on a single chip. This is the first time that an integrated microfluidic system for the detection of viruses infecting the Phalaenopsis orchid has been demonstrated. The sensitivity of the developed system was also explored in this study to validate its performance. From the Clinical Editor: In this study, the authors report the development of an integrated microfluidic system for rapid and automatic detection of viruses by direct analysis of fresh Phalaenopsis orchid leaves, performing the 3-step protocol using a single chip. Similar methods may find clinical application for fast and accurate detection of viral infections. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1274 / 1282
页数:9
相关论文
共 50 条
  • [21] Rapid detection of Salmonella typhimurium on fresh spinach leaves using phage-immobilized magnetoelastic biosensors
    Horikawa, Shin
    Li, Suiqiong
    Chai, Yating
    Park, Mi-Kyun
    Shen, When
    Barbaree, James M.
    Vodyanoy, Vitaly J.
    Chin, Bryan A.
    SENSING FOR AGRICULTURE AND FOOD QUALITY AND SAFETY III, 2011, 8027
  • [22] Simultaneous detection of SARS-CoV-2 and influenza A/B viruses on an electromagnetically-driven, integrated microfluidic system
    Chiu, Chien-Hsin
    Wang, Chih-Hung
    Lin, Ying-Jun
    Tang, Chi -Chung
    Peng, Wei-Jei
    Huang, Wen -Yen
    Shan, Yan-Shen
    Tsai, Huey-Pin
    Lee, Gwo-Bin
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 410
  • [23] An integrated microfluidic system for live bacteria detection from human joint fluid samples by using ethidium monoazide and loop-mediated isothermal amplification
    Shu-Ling Chen
    Wen-Hsin Chang
    Chih-Hung Wang
    Huey-Ling You
    Jiunn-Jong Wu
    Ting-Hang Liu
    Mel S. Lee
    Gwo-Bin Lee
    Microfluidics and Nanofluidics, 2017, 21
  • [24] Rapid detection of thiabendazole pesticide residue in fresh tea leaves using surface-enhanced Raman spectroscopy
    Lin, Lei
    Wu, Rui-Mei
    Guo, Ping
    Liu, Mu-Hua
    Wang, Xiao-Bin
    Ai, Shi-Rong
    Yan, Lin-Yuan
    Modern Food Science and Technology, 2015, 31 (05) : 291 - 296
  • [25] An integrated microfluidic system for live bacteria detection from human joint fluid samples by using ethidium monoazide and loop-mediated isothermal amplification
    Chen, Shu-Ling
    Chang, Wen-Hsin
    Wang, Chih-Hung
    You, Huey-Ling
    Wu, Jiunn-Jong
    Liu, Ting-Hang
    Lee, Mel S.
    Lee, Gwo-Bin
    MICROFLUIDICS AND NANOFLUIDICS, 2017, 21 (05)
  • [26] Multichannel microfluidic virus sensor for rapid detection of respiratory viruses using virus-imprinted polymer for digital livestock farming
    Khan R.R.
    Ibrahim H.
    Rawal G.
    Zhang J.
    Lu M.
    Dong L.
    Sensors and Actuators B: Chemical, 2023, 389
  • [27] A multi-functional electrochemical sensing system using microfluidic technology for the detection of urea and creatinine
    Huang, Chao-June
    Lin, Jiun-Lin
    Chen, Ping-Hong
    Syu, Mei-Jywan
    Lee, Gwo-Bin
    ELECTROPHORESIS, 2011, 32 (08) : 931 - 938
  • [28] A microfluidic immunomagnetic bead-based system for the rapid detection of influenza infections: from purified virus particles to clinical specimens
    Lien-Yu Hung
    Tze-Bin Huang
    Yi-Che Tsai
    Chen-Sheng Yeh
    Huan-Yao Lei
    Gwo-Bin Lee
    Biomedical Microdevices, 2013, 15 : 539 - 551
  • [29] Detection and Discrimination Modeling of Cells in Droplet Using Impedance Spectroscopy-Based Microfluidic System
    Chowdhury, Shabbir
    Hussain, Mohammad Asif
    Sobahi, Nebras
    INTERNATIONAL TRANSACTION JOURNAL OF ENGINEERING MANAGEMENT & APPLIED SCIENCES & TECHNOLOGIES, 2022, 13 (03):
  • [30] Using a Microfluidic-Microelectric Device to Directly Separate Serum/Blood Cells from a Continuous Whole Bloodstream Flow
    Wang, Ming-Wen
    Jeng, Kuo-Shyang
    Yu, Ming-Che
    Su, Jui-Chih
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2012, 51 (03)