Detection of viruses directly from the fresh leaves of a Phalaenopsis orchid using a microfluidic system

被引:32
|
作者
Chang, Wen-Hsin [1 ]
Yang, Sung-Yi [1 ]
Lin, Chih-Lin [1 ]
Wang, Chih-Hung [1 ]
Li, Ping-Chen [4 ]
Chen, Tzong-Yueh [5 ]
Jan, Fuh-Jyh [4 ]
Lee, Gwo-Bin [2 ,3 ]
机构
[1] Natl Tsing Hua Univ, Dept Power Mech Engn, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Inst Biomed Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst Nanoengn & Microsyst, Hsinchu, Taiwan
[4] Natl Chung Hsing Univ, Dept Plant Pathol, Taichung 400, Taiwan
[5] Natl Cheng Kung Univ, Inst Biotechnol, Tainan, Taiwan
关键词
Microfluidics; Phalaenopsis orchid; Pathogen detection; Loop-mediated-isothermal-amplification; MEDIATED-ISOTHERMAL-AMPLIFICATION; ODONTOGLOSSUM RINGSPOT TOBAMOVIRUS; CYMBIDIUM MOSAIC POTEXVIRUS; QUANTITATIVE DETECTION; DIAGNOSTIC DEVICE; RAPID DETECTION; DNA; POINT; GENE; CARE;
D O I
10.1016/j.nano.2013.05.016
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Early detection of pathogens is crucial for the effective surveillance of diseases. Many efforts have been made to explore methods which can detect these pathogens within a short period of time without requiring a tedious protocol. However, these developed methods have disadvantages such as they are relatively time-consuming or require specialized laboratory facilities. In this work, we have developed an integrated microfluidic system for rapid and automatic detection of viruses by direct analysis from fresh Phalaenopsis orchid leaves. The entire protocol, including ribonucleic acid (RNA) purification, reverse transcription loop-mediated-isothermal-amplification (RT-LAMP) and optical detection by measuring changes in turbidity was performed on a single chip. This is the first time that an integrated microfluidic system for the detection of viruses infecting the Phalaenopsis orchid has been demonstrated. The sensitivity of the developed system was also explored in this study to validate its performance. From the Clinical Editor: In this study, the authors report the development of an integrated microfluidic system for rapid and automatic detection of viruses by direct analysis of fresh Phalaenopsis orchid leaves, performing the 3-step protocol using a single chip. Similar methods may find clinical application for fast and accurate detection of viral infections. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1274 / 1282
页数:9
相关论文
共 50 条
  • [1] A microfluidic system integrated with buried optical fibers for detection of Phalaenopsis orchid pathogens
    Lin, Chih-Lin
    Chang, Wen-Hsin
    Wang, Chih-Hung
    Lee, Chia-Hwa
    Chen, Tzong-Yueh
    Jan, Fuh-Jyh
    Lee, Gwo-Bin
    BIOSENSORS & BIOELECTRONICS, 2015, 63 : 572 - 579
  • [2] Pathogen Detection from Phalaenopsis Orchids by Using an Integrated Microfluidic System
    Chang, Wen-Hsin
    Yang, Sung-Yi
    Wang, Chih-Hung
    Lee, Gwo-Bin
    Chen, Tzong-Yeh
    6TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE AND ENGINEERING (IEEE-NANOMED 2012), 2012, : 6 - 10
  • [3] Detection of two orchid viruses using quartz crystal microbalance (QCM) immunosensors
    Eun, AJC
    Huang, LQ
    Chew, FT
    Li, SFY
    Wong, SM
    JOURNAL OF VIROLOGICAL METHODS, 2002, 99 (1-2) : 71 - 79
  • [4] Direct detection of orchid viruses using nanorod-based fiber optic particle plasmon resonance immunosensor
    Lin, Hsing-Ying
    Huang, Chen-Han
    Lu, Sin-Hong
    Kuo, I-Ting
    Chau, Lai-Kwan
    BIOSENSORS & BIOELECTRONICS, 2014, 51 : 371 - 378
  • [5] Integrated microfluidic system for the identification and multiple subtyping of influenza viruses by using a molecular diagnostic approach
    Wang, Chih-Hung
    Lien, Kang-Yi
    Hung, Lien-Yu
    Lei, Huan-Yao
    Lee, Gwo-Bin
    MICROFLUIDICS AND NANOFLUIDICS, 2012, 13 (01) : 113 - 123
  • [6] Orchid Virus Detection from Orchid Leaves Using Micro/Nano Hybrid-Structured Immuno-Electrochemical Biosensor
    Wang, Wei-Jhen
    Lee, Chia-Hwa
    Li, Chin-Wen
    Liao, Stephen
    Jan, Fuh-Jyh
    Wang, Gou-Jen
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
  • [7] Rapid simultaneous detection of two orchid viruses using LC- and/or MALDI-mass spectrometry
    Tan, SWL
    Wong, SM
    Kini, RM
    JOURNAL OF VIROLOGICAL METHODS, 2000, 85 (1-2) : 93 - 99
  • [8] An integrated microfluidic loop-mediated-isothermal-amplification system for rapid sample pre-treatment and detection of viruses
    Wang, Chih-Hung
    Lien, Kang-Yi
    Wang, Ting-Yu
    Chen, Tzong-Yueh
    Lee, Gwo-Bin
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05) : 2045 - 2052
  • [9] An integrated microfluidic platform for rapid detection and subtyping of influenza viruses from clinical samples
    Tai, Chien-Hsuan
    Tsai, Yi-Che
    Wang, Chih-Hung
    Ho, Tzong-Shiann
    Chang, Chih-Peng
    Lee, Gwo-Bin
    MICROFLUIDICS AND NANOFLUIDICS, 2014, 16 (03) : 501 - 512
  • [10] Rapid Detection of Streptococcus mutans Using an Integrated Microfluidic System with Loop-Mediated Isothermal Amplification
    Wang, Jingfu
    Wang, Jingyi
    Chang, Xin
    Shang, Jin
    Wang, Yuehui
    Ma, Qin
    Shen, Liangliang
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2023, 33 (08) : 1101 - 1110