Comparison of graphite-to-water absorbed-dose transfers for Co-60 photon beams using ionometry and Fricke dosimetry

被引:16
|
作者
Chauvenet, B
Baltes, D
Delaunay, F
机构
[1] BNM-LPRI, CEA/Saclay, BP n 52
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1997年 / 42卷 / 11期
关键词
D O I
10.1088/0031-9155/42/11/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To derive the absorbed dose to water from a standard of absorbed dose to graphite, the metrology laboratories which apply such a method usually make use of cavity ionization chambers as transfer instruments. In addition, the BNM-LPRI has tested, as such instruments, two types of Fricke dosimeter in its cobalt-60 beam The two procedures are compared and their results are found to be in good agreement (the difference is less than 0.1%). Both procedures are then taken into account for the calculation of the reference value of absorbed dose to water.
引用
收藏
页码:2053 / 2063
页数:11
相关论文
共 50 条
  • [31] AIR CAVITY EFFECTS ON THE RADIATION-DOSE TO THE LARYNX USING CO-60, 6 MV, AND 10 MV PHOTON BEAMS
    NIROOMANDRAD, A
    HARTER, KW
    THOBEJANE, S
    BERTRAND, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 29 (05): : 1139 - 1146
  • [32] GRAPHITE CALORIMETER IN WATER PHANTOM AND CALIBRATION OF IONIZATION CHAMBERS IN DOSE TO WATER FOR CO-60 GAMMA-RADIATION
    RAO, ISS
    NAIK, SB
    MEDICAL PHYSICS, 1980, 7 (03) : 196 - 201
  • [33] Comparison of Absorbed-Dose to Water in High-Energy Photon Beams Based On Addendum AAPM TG-51, IAEA TRS-398, and JS']JSMP 12
    Kinoshita, N.
    Oguchi, H.
    Kita, A.
    Yoshioka, C.
    Sasamoto, K.
    Nishimoto, Y.
    Adachi, T.
    Shioura, H.
    Kimura, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3379 - 3379
  • [34] ASSESSMENT OF ABSORBED DOSE TO WATER IN HIGH ENERGY PHOTON BEAMS USING DIFFERENT CYLINDRICAL CHAMBERS
    Stancu, Elena
    Vancea, Catalin
    Valenta, Jiri
    Zeman, Josef
    Badita, Eugenia
    Scarisoreanu, Anca
    ROMANIAN REPORTS IN PHYSICS, 2015, 67 (02) : 693 - 699
  • [35] A water calorimeter for on-site absorbed dose to water calibrations in 60Co and MV-photon beams including MRI incorporated treatment equipment
    de Prez, Leon
    de Pooter, Jacco
    Jansen, Bartel
    Aalbers, Tony
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (13): : 5051 - 5076
  • [36] Dosimetry of interface region near closed air cavities for Co-60, 6 MV and 15 MV photon beams using Monte Carlo simulations
    Joshi, Chandra P.
    Darko, Johnson
    Vidyasagar, P. B.
    Schreiner, L. John
    JOURNAL OF MEDICAL PHYSICS, 2010, 35 (02) : 73 - 80
  • [37] A standard for absorbed dose rate to water in a 60Co field using a graphite calorimeter at the National Metrology Institute of Japan
    Morishita, Y.
    Kato, M.
    Takata, N.
    Kurosawa, T.
    Tanaka, T.
    Saito, N.
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 331 - 339
  • [38] POSTAL DOSE INTERCOMPARISON OF CO-60 DOSIMETRY USING THERMO-LUMINESCENCE DOSIMETERS AMONG SECONDARY STANDARD DOSIMETRY LABORATORIES
    BOYD, AW
    EISENLOHR, HH
    GIRZIKOWSKY, R
    MEDICAL PHYSICS, 1982, 9 (01) : 112 - 113
  • [39] Comparison of the IAEA TRS-398 and AAPM TG-51 absorbed dose to water protocols in the dosimetry of high-energy photon and electron beams
    Huq, MS
    Andreo, P
    Song, HJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11): : 2985 - 3006
  • [40] Comparison of absorbed-dose-to-water units for Co-60 and high-energy x-rays between PTB and LNE-LNHB
    Delaunay, F.
    Kapsch, R-P
    Gouriou, J.
    Illemann, J.
    Krauss, A.
    Le Roy, M.
    Ostrowsky, A.
    Sommier, L.
    Vermesse, D.
    METROLOGIA, 2012, 49 (05) : S203 - S206