Artifacts Reduction in Low-Contrast Neurological Imaging with C-arm System

被引:0
|
作者
Xia, Dan [1 ]
Chang, Yu-Bing [2 ]
Siddiqui, Adnan H. [3 ]
Zhang, Zheng [1 ]
Manak, Joe [2 ]
Sidky, Emil Y. [1 ]
Pan, Xiaochuan [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Canon Med Res USA Inc, Vernon Hills, IL 60061 USA
[3] Univ Buffalo Neurosurg Inc, Buffalo, NY 14203 USA
来源
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING | 2018年 / 10573卷
关键词
COMPUTED-TOMOGRAPHY;
D O I
10.1117/12.2293629
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
C-arm cone-beam CT (CBCT) is adopted rapidly for imaging-guidance in interventional and surgical procedures. However, measured CBCT data are truncated often due to the limited detector size especially in the presence of additional interventional devices outside the imaging field of view (FOV). In our previous work, it has been demonstrated that a constrained optimization-based reconstruction with an additional data-derivative fidelity term can effectively suppress the truncation artifacts. In this work, in attempt to evaluate the optimization-based reconstruction, two task-relevant metrics, are proposed for characterization of the recovery of the low-contrast objects and the reduction of streak artifacts. Results demonstrate that the optimization program and the associated CP algorithms can significantly reduce streak artifacts, leading to improved visualization of low contrast structures in the reconstruction relative to clinical FDK reconstruction.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Reproducibility of Parenchymal Blood Volume Measurements Using an Angiographic C-arm CT System
    Mueller, Kerstin
    Fahrig, Rebecca
    Manhart, Michael
    Deuerling-Zheng, Yu
    Rosenberg, Jarrett
    Moore, Teri
    Ganguly, Arundhuti
    Kothary, Nishita
    ACADEMIC RADIOLOGY, 2016, 23 (11) : 1441 - 1445
  • [22] Shielding effect of radiation dose reduction fiber during the use of C-arm fluoroscopy: a phantom study
    Cha, Hyemi
    Lee, Kisung
    Park, Moon Seok
    Lee, Kyoung Min
    Cho, Kyeyoung
    Sung, Ki Hyuk
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (05) : 705 - 711
  • [23] Extended ellipse-line-ellipse trajectory for long-object cone-beam imaging with a mounted C-arm system
    Yu, Zhicong
    Lauritsch, Guenter
    Dennerlein, Frank
    Mao, Yanfei
    Hornegger, Joachim
    Noo, Frederic
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04) : 1829 - 1851
  • [24] Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction
    Wang, Adam S.
    Stayman, J. Webster
    Otake, Yoshito
    Kleinszig, Gerhard
    Vogt, Sebastian
    Gallia, Gary L.
    Khanna, A. Jay
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (04) : 1005 - 1026
  • [25] Assessment of a photon-counting detector for a dual-energy C-arm angiographic system
    Ahmad, Moiz
    Fahrig, Rebecca
    Pung, Leland
    Spahn, Martin
    Koester, Niko S.
    Reitz, Silke
    Moore, Teri
    Choi, Jang-Hwan
    Hinshaw, Waldo
    Xia, Yan
    Mueller, Kerstin
    MEDICAL PHYSICS, 2017, 44 (11) : 5938 - 5948
  • [26] Unprecedented journey to 650 transpedicular screws using freehand technique and intraoperative C-arm imaging with technical nuances
    Fayaz, Mohsin
    Chibber, Sarabjit Singh
    Singh, Kaushal Deep
    Tyngkam, Lamkordor
    Hela, Amir
    Chaurasia, Bipin
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2024, 15 (03) : 326 - 330
  • [27] The Added Value of Volume-of-Interest C-Arm CT Imaging during Endovascular Treatment of Intracranial Aneurysms
    Chintalapani, G.
    Chinnadurai, P.
    Maier, A.
    Xia, Y.
    Bauer, S.
    Shaltoni, H.
    Morsi, H.
    Mawad, M. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 660 - 666
  • [28] Compressed-sensing-based three-dimensional image reconstruction algorithm for C-arm vascular imaging
    Selim, Mona
    al-Shatouri, Mohammad
    Kudo, Hiroyuki
    Rashed, Essam A.
    2014 CAIRO INTERNATIONAL BIOMEDICAL ENGINEERING CONFERENCE (CIBEC), 2014, : 111 - 114
  • [29] Reliability and Usefulness of Intraoperative 3-Dimensional Imaging by Mobile C-Arm With Flat-Panel Detector
    Fujimori, Takahito
    Iwasaki, Motoki
    Nagamoto, Yukitaka
    Kashii, Masafumi
    Takao, Masaki
    Sugiura, Tsuyoshi
    Yoshikawa, Hideki
    CLINICAL SPINE SURGERY, 2017, 30 (01): : E64 - E75
  • [30] Multi-modality diagnostic imaging of a cervical articular process fracture in a Thoroughbred horse including a novel C-Arm imaging technique
    Witherst, J. M.
    Voute, L. C.
    Lischer, C. J.
    EQUINE VETERINARY EDUCATION, 2009, 21 (10) : 540 - 545