Fracture of femoral component in a resurfacing total knee arthroplasty

被引:17
|
作者
Michos, John [1 ]
Rallis, John [1 ]
Fassoulas, Apostolos [1 ]
机构
[1] Asclep Voula Hosp, Dept Orthopaed, Athens, Greece
来源
JOURNAL OF ARTHROPLASTY | 2006年 / 21卷 / 07期
关键词
fracture; femoral component; total knee arthroplasty;
D O I
10.1016/j.arth.2005.10.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We present a case of an unusual complication after a resurfacing total knee arthroplasty. Fracture of the uncemented porous-coated femoral component occurred 4 years after its implantation. The mechanical axis was restored and collateral ligament balance was achieved at the primary procedure. At revision, the femoral component was found fractured at the junction of the trochlea with the medial condyle, anteriorly to the medial peg. A thin layer of fibrous tissue was interposed between bone and metal under the fracture area. Metallurgical analysis of the fractured component revealed fatigue failure but no structural defect. Lack of bony support and excessive cyclic loading led to fracture of the implant.
引用
收藏
页码:1068 / 1071
页数:4
相关论文
共 50 条
  • [41] Patellar resurfacing complications in total knee arthroplasty
    Panni, Alfredo Schiavone
    Cerciello, Simone
    Del Regno, Chiara
    Felici, Alessandro
    Vasso, Michele
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (02) : 313 - 317
  • [42] Secondary resurfacing of the patella in total knee arthroplasty
    Spencer, Simon J.
    Young, David
    Blyth, Mark J. G.
    KNEE, 2010, 17 (03): : 187 - 190
  • [43] Patellar resurfacing in total knee arthroplasty - Reply
    Waters, TS
    Bentley, G
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12): : 2484 - 2484
  • [44] TECHNIQUE FOR PATELLAR RESURFACING IN TOTAL KNEE ARTHROPLASTY
    MARMOR, L
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (230) : 166 - 167
  • [45] The effect of femoral component rotation on patellar tracking in total knee arthroplasty
    Luring, Christian
    Perlick, Lars
    Baethis, Holger
    Tingart, Markus
    Grifka, Joachim
    ORTHOPEDICS, 2007, 30 (11) : 965 - 967
  • [46] An oxidized Zr ceramic surfaced femoral component for total knee arthroplasty
    Laskin, RS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) : 191 - 196
  • [47] Synchronisation of tibial rotational alignment with femoral component in total knee arthroplasty
    Dong-Hoon Lee
    Jai-Gon Seo
    Young-Wan Moon
    International Orthopaedics, 2008, 32 : 223 - 227
  • [48] Variation in Optimal Sagittal Alignment of the Femoral Component in Total Knee Arthroplasty
    Hood, Brandon
    Blum, Laura
    Holcombe, Sven A.
    Wang, Stewart C.
    Urquhart, Andrew G.
    Goulet, James A.
    Maratt, Joseph D.
    ORTHOPEDICS, 2017, 40 (02) : 102 - 106
  • [49] Intraoperative assessment of femoral component rotational alignment in total knee arthroplasty
    Florian Geiger
    Dominik Parsch
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 267 - 270
  • [50] A clinical study of the rotational alignment of the femoral component in total knee arthroplasty
    Ding, Liangjia
    Liu, Xiaomin
    Liu, Changlu
    Liu, Yingli
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (07) : 2077 - 2081