Fabrification of electroreduced graphene oxide-bentonite sodium composite modified electrode and its sensing application for linezolid

被引:29
作者
Prashanth, S. N. [1 ]
Teradal, Nagappa L. [1 ]
Seetharamappa, J. [1 ]
Satpati, Ashis K. [2 ]
Reddy, A. V. R. [2 ]
机构
[1] Karnatak Univ, Dept Chem, Dharwad 580003, Karnataka, India
[2] Bhabha Atom Res Ctr, Div Analyt Chem, Bombay 400085, Maharashtra, India
关键词
Graphene; Bentonite; Electroreduction; Linezolid; Electrochemical Sensor; CLAY-MODIFIED ELECTRODES; PALLADIUM NANOPARTICLES; HUMAN PLASMA; VOLTAMMETRY; NANOSHEETS; BEHAVIOR; SENSOR; AGENTS; DRUGS;
D O I
10.1016/j.electacta.2014.04.022
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Graphene and its composites have attracted considerable attention in synthesis and electrochemical applications. In the present work, we have synthesized and characterized graphene oxide-bentonite composite (GO-BEN) and utilized it to fabricate an electrochemical sensor. For this, the solution of GO-BEN cast on glassy carbon electrode (GCE) was reduced electrochemically in phosphate buffer solution of pH 6 to obtain electrochemically reduced graphene oxide-bentonite composite (ERGO-BEN-GCE). This ERGO-BEN film was used for electrochemical investigation of an oxazolidinone class of antibiotic, linezolid (LIN) for the first time. The electrochemical sensor showed excellent enhancement and adsorptive ability towards the electrooxidation of LIN. UN exhibited two each of oxidation and reduction peaks on ERGO-BEN film in phosphate buffer of pH 7.0. Effects of accumulation time, pH of solution and scan rate were studied and various electrochemical parameters were evaluated. The plot of pH versus Ep gave a slope of 26.2 mV/pH in the pH range of 4.2-8.0 indicating the participation of two electrons and one proton in the electrode process. An adsorptive stripping differential pulse voltammetric method (AdSDPV) was developed for the determination of LIN in bulk, pharmaceutical formulations and urine samples. Adsorptive stripping linear sweep voltammetric (AdSLSV) and differential pulse voltammetric (DPV) methods were also developed and the results were compared. LIN showed linear relationship between the current density and concentration in the range of 0.25 - 31.25 mu M with a LOD of 0.0337 mu M in AdSDPV method; 0.5 -31.25 mu M with a LOD of 0.100 mu M in DPV method and 1.25-37.5 mu M with a LOD of 0.5461 mu M in AdSLSV method respectively. The proposed AdSDPV method was observed to be simple, fast and inexpensive and hence, could be readily adopted for quality control in pharmaceutical products. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 52 条
[1]  
[Anonymous], INT J ELECTROCHEM, DOI DOI 10.1016/J.LITH0S.2011.07.027
[2]   Graphene oxide/conducting polymer composite hydrogels [J].
Bai, Hua ;
Sheng, Kaixuan ;
Zhang, Pengfei ;
Li, Chun ;
Shi, Gaoquan .
JOURNAL OF MATERIALS CHEMISTRY, 2011, 21 (46) :18653-18658
[3]   High surface area montmorillonite-carbon composites and derived carbons [J].
Bakandritsos, A ;
Steriotis, T ;
Petridis, D .
CHEMISTRY OF MATERIALS, 2004, 16 (08) :1551-1559
[4]   Cyclic voltammetry of aquocobalamin on clay-modified electrodes [J].
Borek, V ;
Morra, MJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (14) :2149-2153
[5]   Determination of linezolid in human serum and urine by high-performance liquid chromatography [J].
Borner, K ;
Borner, E ;
Lode, H .
INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2001, 18 (03) :253-258
[6]   Synthesis and antibacterial activity of U-100592 and U-100766, two oxazolidinone antibacterial agents for the potential treatment of multidrug-resistant Gram-positive bacterial infections [J].
Brickner, SJ ;
Hutchinson, DK ;
Barbachyn, MR ;
Manninen, PR ;
Ulanowicz, DA ;
Garmon, SA ;
Grega, KC ;
Hendges, SK ;
Toops, DS ;
Ford, CW ;
Zurenko, GE .
JOURNAL OF MEDICINAL CHEMISTRY, 1996, 39 (03) :673-679
[7]   Polypropylene-grafted graphene oxide sheets as multifunctional compatibilizers for polyolefin-based polymer blends [J].
Cao, Yewen ;
Feng, Jiachun ;
Wu, Peiyi .
JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (30) :14997-15005
[8]   Electrochemical immunosensor for carcinoembryonic antigen based on nanosilver-coated magnetic beads and gold-graphene nanolabels [J].
Chen, Huafeng ;
Tang, Dianping ;
Zhang, Bing ;
Liu, Bingqian ;
Cui, Yuling ;
Chen, Guonan .
TALANTA, 2012, 91 :95-102
[9]   Determination of Explosives Using Electrochemically Reduced Graphene [J].
Chen, Ti-Wei ;
Sheng, Zhen-Huan ;
Wang, Kang ;
Wang, Feng-Bin ;
Xia, Xing-Hua .
CHEMISTRY-AN ASIAN JOURNAL, 2011, 6 (05) :1210-1216
[10]   Linezolid [J].
Clemett, D ;
Markham, A .
DRUGS, 2000, 59 (04) :815-827