Influence of surface modification and static pressure on microdialysis protein extraction efficiency

被引:3
作者
Chu, Jiangtao [1 ]
Undin, Torgny [2 ]
Lind, Sara Bergstrom [2 ]
Hjort, Klas [1 ]
Dahlin, Andreas P. [1 ]
机构
[1] Uppsala Univ, Dept Engn Sci, SE-75121 Uppsala, Sweden
[2] Uppsala Univ, Dept Chem, BMC, Analyt Chem & Sci Life Lab, SE-75124 Uppsala, Sweden
基金
瑞典研究理事会;
关键词
Microdialysis; Surface modification; Poloxamer; Protein; Extraction efficiency; IN-VITRO; HUMAN BRAIN; QUANTIFICATION; CYTOKINES; IMPACT; INJURY;
D O I
10.1007/s10544-015-0005-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There is growing interest in using microdialysis (MD) for monitoring larger and more complex molecules such as neuropeptides and proteins. This promotes the use of MD membranes with molecular weight cut off (MWCO) of 100 kDa or above. The hydrodynamic property of the membrane goes to ultrafiltration or beyond, making the MD catheters more sensitive to pressure. In the meantime, despite the large pore size, studies have shown that membrane biofouling still lead to unstable catheter performance. The objective is to study in vitro how 500 kDa dextran and Poloxamer 407 surface modification affect the fluid recovery (FR) and extraction efficiency (EE) of 100 kDa MWCO MD catheters. A pressure chamber was designed to facilitate the tests, using as MD sample a protein standard with similar concentrations as in human cerebral spinal fluid, comparing native and Poloxamer 407 modified MD catheters. The collected dialysate fractions were examined for FR and protein EE, employing Dot-it Spot-it Protein Assay for total protein EE and targeted mass spectrometry (MS) for EE of individual proteins and peptides. The FR results suggested that the surface modified catheters were less sensitive to the pressure and provide higher precision, and provided a FR closer to 100 %. The surface modification did not show a significant effect on the protein EE. The average total protein EE of surface modified catheters was slightly higher than that of the native ones. The MS EE data of individual proteins showed a clear trend of complex response in EE with pressure.
引用
收藏
页数:11
相关论文
共 29 条
[1]   Microdialysis sampling of cytokines [J].
Ao, XP ;
Stenken, JA .
METHODS, 2006, 38 (04) :331-341
[2]  
Chaurasia CS, 1999, BIOMED CHROMATOGR, V13, P317, DOI 10.1002/(SICI)1099-0801(199908)13:5<317::AID-BMC891>3.0.CO
[3]  
2-I
[4]   Fluorescence imaging of macromolecule transport in high molecular weight cut-off microdialysis [J].
Chu, Jiangtao ;
Koudriavtsev, Vitali ;
Hjort, Klas ;
Dahlin, Andreas P. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (29) :7601-7609
[5]   Impact of static pressure on transmembrane fluid exchange in high molecular weight cut off microdialysis [J].
Chu, Jiangtao ;
Hjort, Klas ;
Larsson, Anders ;
Dahlin, Andreas P. .
BIOMEDICAL MICRODEVICES, 2014, 16 (02) :301-310
[6]   What can microdialysis tell us about the temporal and spatial generation of cytokines in allergen-induced responses in human skin in vivo? [J].
Clough, Geraldine F. ;
Jackson, Claire L. ;
Lee, Jacob J. P. ;
Jamal, Sarah C. ;
Church, Martin K. .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2007, 127 (12) :2799-2806
[7]   Tethered polymer chains: surface chemistry and their impact on colloidal and surface properties [J].
Currie, EPK ;
Norde, W ;
Stuart, MAC .
ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2003, 100 :205-265
[8]   Refined Microdialysis Method for Protein Biomarker Sampling in Acute Brain Injury in the Neurointensive Care Setting [J].
Dahlin, Andreas P. ;
Purins, Karlis ;
Clausen, Fredrik ;
Chu, Jiangtao ;
Sedigh, Amir ;
Lorant, Tomas ;
Enblad, Per ;
Lewen, Anders ;
Hillered, Lars .
ANALYTICAL CHEMISTRY, 2014, 86 (17) :8671-8679
[9]   Multiplexed quantification of proteins adsorbed to surface-modified and non-modified microdialysis membranes [J].
Dahlin, Andreas P. ;
Hjort, Klas ;
Hillered, Lars ;
Sjodin, Marcus O. D. ;
Bergquist, Jonas ;
Wetterhall, Magnus .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (06) :2057-2067
[10]   Methodological Aspects on Microdialysis Protein Sampling and Quantification in Biological Fluids: An In Vitro Study on Human Ventricular CSF [J].
Dahlin, Andreas P. ;
Wetterhall, Magnus ;
Caldwell, Karin D. ;
Larsson, Anders ;
Bergquist, Jonas ;
Hillered, Lars ;
Hjort, Klas .
ANALYTICAL CHEMISTRY, 2010, 82 (11) :4376-4385