Detection of malignant hepatic tumors with ferumoxide-enhanced MR imaging: usefulness of multishot and single-shot fast spin echo sequences

被引:4
作者
Goshima, S
Kanematsu, M
Matsuo, M
Murakami, T
Hori, M
Takamura, M
Kondo, H
Kako, N
Moriyama, N
Nakamura, H
Hoshi, H
机构
[1] Gifu Univ, Sch Med, Dept Radiol, Gifu 5008705, Japan
[2] Osaka Univ, Sch Med, Dept Radiol, Suita, Osaka 5650871, Japan
[3] Natl Canc Ctr, Dept Diagnost Radiol, Chuo Ku, Tokyo 1040045, Japan
关键词
liver; magnetic resonance (MR); multishot; single-shot; fast SE; GRE; MR; contrast enhancement;
D O I
10.1016/j.mri.2004.01.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of our study was to assess whether respiratory-triggered multishot fast spin echo (MS-FSE) and breath-hold half-Fourier single-shot fast spin echo (SS-FSE) images, in addition to breath-hold T-2*-weighted gradient recalled echo (GRE) images, increase observer performance in the detection of malignant hepatic tumors with ferumoxide-enhanced magnetic resonance (MR) imaging. Ferumoxide-enhanced MR images obtained from 48 patients with 83 malignant hepatic tumors were retrospectively reviewed by three independent off-site readers. In the first image review, GRE images alone were reviewed. Then, MS-FSE images were added for the first combination review. Finally, SS-FSE images were added for the second combination review. Observer performances were tested by McNemar's test and receiver-operating-characteristic analysis for the clustered data. Sensitivity for hepatocellular carcinomas, metastases, and malignant hepatic tumors overall was significantly (p < 0.05) higher with GRE and MS-FSE combined and GRE, MS-FSE and SS-FSE combined than with GRE alone. For metastases, the Az value was significantly (p < 0.05) higher with GRE and MS-FSE combined, and GRE, MS-FSE and SS-FSE combined than with GRE alone. We confirmed the incremental value of ferumoxide-enhanced MR imaging by obtaining MS-FSE and SS-FSE images in addition to GRE images in the detection of malignant hepatic tumors. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:379 / 388
页数:10
相关论文
共 33 条
[1]   LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING [J].
BELLIN, MF ;
ZAIM, S ;
AUBERTON, E ;
SARFATI, G ;
DURON, JJ ;
KHAYAT, D ;
GRELLET, J .
RADIOLOGY, 1994, 193 (03) :657-663
[2]   MR of focal liver lesions: Comparison of breath-hold and non-breath-hold hybrid RARE and conventional spin-echo T2-weighted pulse sequences [J].
Carpenter, KD ;
Macaulay, SE ;
Schulte, SJ ;
Obregon, RG ;
Nelson, RC ;
Simon, HE ;
Schmiedl, UP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) :596-602
[3]   SUPERPARAMAGNETIC IRON-OXIDE - DETECTION OF FOCAL LIVER-LESIONS AT HIGH-FIELD-STRENGTH MR-IMAGING [J].
DUDA, SH ;
LANIADO, M ;
KOPP, AF ;
GRONEWALLER, E ;
AICHER, KP ;
PAVONE, P ;
JEHLE, E ;
CLAUSSEN, CD .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :309-314
[4]   Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging [J].
Gaa, J ;
Hatabu, H ;
Jenkins, RL ;
Finn, JP ;
Edelman, RR .
RADIOLOGY, 1996, 200 (02) :459-464
[5]   DIFFERENTIATION OF HEPATIC HEMANGIOMAS FROM METASTASES BY DYNAMIC CONTRAST-ENHANCED MR IMAGING [J].
HAMM, B ;
FISCHER, E ;
TAUPITZ, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (02) :205-216
[6]  
HOE LV, 1996, RADIOLOGY, V201, P817
[7]   Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging [J].
Hori, M ;
Murakami, T ;
Kim, T ;
Kanematsu, M ;
Tsuda, K ;
Takahashi, S ;
Takamura, M ;
Hoshi, H ;
Nakamura, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) :1423-1431
[8]  
Kanematsu M, 2001, J MAGN RESON IMAGING, V13, P249, DOI 10.1002/1522-2586(200102)13:2<249::AID-JMRI1036>3.0.CO
[9]  
2-C
[10]   HYPERVASCULAR MALIGNANT LIVER-LESIONS - COMPARISON OF VARIOUS MR-IMAGING PULSE SEQUENCES AND DYNAMIC CT [J].
LARSON, RE ;
SEMELKA, RC ;
BAGLEY, AS ;
MOLINA, PL ;
BROWN, ED ;
LEE, JKT .
RADIOLOGY, 1994, 192 (02) :393-399