Detection of malignant hepatic tumors with ferumoxide-enhanced MR imaging: usefulness of multishot and single-shot fast spin echo sequences

被引:4
作者
Goshima, S
Kanematsu, M
Matsuo, M
Murakami, T
Hori, M
Takamura, M
Kondo, H
Kako, N
Moriyama, N
Nakamura, H
Hoshi, H
机构
[1] Gifu Univ, Sch Med, Dept Radiol, Gifu 5008705, Japan
[2] Osaka Univ, Sch Med, Dept Radiol, Suita, Osaka 5650871, Japan
[3] Natl Canc Ctr, Dept Diagnost Radiol, Chuo Ku, Tokyo 1040045, Japan
关键词
liver; magnetic resonance (MR); multishot; single-shot; fast SE; GRE; MR; contrast enhancement;
D O I
10.1016/j.mri.2004.01.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of our study was to assess whether respiratory-triggered multishot fast spin echo (MS-FSE) and breath-hold half-Fourier single-shot fast spin echo (SS-FSE) images, in addition to breath-hold T-2*-weighted gradient recalled echo (GRE) images, increase observer performance in the detection of malignant hepatic tumors with ferumoxide-enhanced magnetic resonance (MR) imaging. Ferumoxide-enhanced MR images obtained from 48 patients with 83 malignant hepatic tumors were retrospectively reviewed by three independent off-site readers. In the first image review, GRE images alone were reviewed. Then, MS-FSE images were added for the first combination review. Finally, SS-FSE images were added for the second combination review. Observer performances were tested by McNemar's test and receiver-operating-characteristic analysis for the clustered data. Sensitivity for hepatocellular carcinomas, metastases, and malignant hepatic tumors overall was significantly (p < 0.05) higher with GRE and MS-FSE combined and GRE, MS-FSE and SS-FSE combined than with GRE alone. For metastases, the Az value was significantly (p < 0.05) higher with GRE and MS-FSE combined, and GRE, MS-FSE and SS-FSE combined than with GRE alone. We confirmed the incremental value of ferumoxide-enhanced MR imaging by obtaining MS-FSE and SS-FSE images in addition to GRE images in the detection of malignant hepatic tumors. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:379 / 388
页数:10
相关论文
共 33 条
  • [1] LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING
    BELLIN, MF
    ZAIM, S
    AUBERTON, E
    SARFATI, G
    DURON, JJ
    KHAYAT, D
    GRELLET, J
    [J]. RADIOLOGY, 1994, 193 (03) : 657 - 663
  • [2] MR of focal liver lesions: Comparison of breath-hold and non-breath-hold hybrid RARE and conventional spin-echo T2-weighted pulse sequences
    Carpenter, KD
    Macaulay, SE
    Schulte, SJ
    Obregon, RG
    Nelson, RC
    Simon, HE
    Schmiedl, UP
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 596 - 602
  • [3] SUPERPARAMAGNETIC IRON-OXIDE - DETECTION OF FOCAL LIVER-LESIONS AT HIGH-FIELD-STRENGTH MR-IMAGING
    DUDA, SH
    LANIADO, M
    KOPP, AF
    GRONEWALLER, E
    AICHER, KP
    PAVONE, P
    JEHLE, E
    CLAUSSEN, CD
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) : 309 - 314
  • [4] Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging
    Gaa, J
    Hatabu, H
    Jenkins, RL
    Finn, JP
    Edelman, RR
    [J]. RADIOLOGY, 1996, 200 (02) : 459 - 464
  • [5] DIFFERENTIATION OF HEPATIC HEMANGIOMAS FROM METASTASES BY DYNAMIC CONTRAST-ENHANCED MR IMAGING
    HAMM, B
    FISCHER, E
    TAUPITZ, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (02) : 205 - 216
  • [6] HOE LV, 1996, RADIOLOGY, V201, P817
  • [7] Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    Hori, M
    Murakami, T
    Kim, T
    Kanematsu, M
    Tsuda, K
    Takahashi, S
    Takamura, M
    Hoshi, H
    Nakamura, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) : 1423 - 1431
  • [8] Kanematsu M, 2001, J MAGN RESON IMAGING, V13, P249, DOI 10.1002/1522-2586(200102)13:2<249::AID-JMRI1036>3.0.CO
  • [9] 2-C
  • [10] HYPERVASCULAR MALIGNANT LIVER-LESIONS - COMPARISON OF VARIOUS MR-IMAGING PULSE SEQUENCES AND DYNAMIC CT
    LARSON, RE
    SEMELKA, RC
    BAGLEY, AS
    MOLINA, PL
    BROWN, ED
    LEE, JKT
    [J]. RADIOLOGY, 1994, 192 (02) : 393 - 399