Determinants of Posterior Corneal Biometric Measurements in a Multi-Ethnic Asian Population

被引:8
作者
Ang, Marcus [1 ,2 ]
Chong, Wesley [1 ]
Huang, Huiqi [2 ]
Wong, Tien Yin [1 ,2 ,3 ,4 ]
He, Ming-Guang [5 ]
Aung, Tin [1 ,2 ,3 ]
Mehta, Jodhbir S. [1 ,2 ,4 ]
机构
[1] Singapore Natl Eye Ctr, Singapore, Singapore
[2] Singapore Eye Res Inst, Singapore, Singapore
[3] Natl Univ Singapore, Dept Ophthalmol, Singapore 117548, Singapore
[4] Duke Natl Univ Singapore, Grad Sch Med, Off Clin Sci, Singapore, Singapore
[5] Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Guangdong, Peoples R China
来源
PLOS ONE | 2014年 / 9卷 / 07期
基金
新加坡国家研究基金会;
关键词
OPTICAL COHERENCE TOMOGRAPHY; IN-SITU KERATOMILEUSIS; AUTOMATED ENDOTHELIAL KERATOPLASTY; LENS POWER CALCULATION; ANTERIOR SEGMENT OCT; ANGLE-CLOSURE; ULTRASOUND BIOMICROSCOPY; REFRACTIVE SURGERY; ASSESSMENT PROGRAM; CHINESE EYES;
D O I
10.1371/journal.pone.0101483
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To describe the corneal and anterior segment determinants of posterior corneal arc length (PCAL) and posterior corneal curvature (PCC). Methods: Cross-sectional, population-based study of 1069 subjects (1069 eyes) aged 40-80 years, from three major Asian ethnic groups. All underwent anterior segment optical coherence tomography imaging and analysis with Zhongshan Angle Assessment Program. Our main outcome measures were determinants of PCAL and PCC using adjusted, multivariate linear regression analysis, adjusted for confounders to obtain the estimated marginal means (EMM) with standard error (SE). Results: The overall mean (+/- SD) of PCC was: 6.51 +/- 0.39 mm; and PCAL was: 12.52 +/- 0.59 mm. Malays had a relatively longer PCAL (EMM = 12.74 mm, SE = 0.04 mm) than Chinese (EMM = 12.48 mm, SE = 0.03 mm, P<0.001), and Indians (EMM = 12.42 mm, SE = 0.03 mm, P<0.001). Anterior segment parameters had weak-moderate correlations with PCAL, which included: anterior chamber depth (ACD) (r = 0.55, P<0.001), PCC (r = 0.27, P<0.001), anterior corneal curvature (ACC) (r = 0.14, P<0.001) and central corneal thickness (CCT) (r = -0.07, P = 0.023). In multivariate analysis, anterior segment parameters explained only 37.6% of the variance of PCAL, with ACD being the most important determinant (partial R-2 = 0.300; P<0.001). The determinants of PCC included ACC, PCAL and CCT (explaining 72.1% variation of PCC), with ACC being the most important determinant (partial R-2 = 0.683; P<0.001). Conclusion: There was moderate correlation of PCAL with ACD, but anterior segment parameters accounted for only a small proportion of the variation in PCAL. The significant differences in PCAL and PCC amongst different Asian ethnic groups suggests that there is a need to consider this factor when planning for anterior segment surgeries such as endothelial keratoplasty.
引用
收藏
页数:7
相关论文
共 38 条
  • [1] ALSBIRK PH, 1978, ACTA OPHTHALMOL, V56, P95
  • [2] ALSBIRK PH, 1978, ACTA OPHTHALMOL, V56, P105
  • [3] Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments
    Ang, Marcus
    Chong, Wesley
    Huang, Huiqi
    Tay, Wan Ting
    Wong, Tien Yin
    He, Ming-Guang
    Aung, Tin
    Mehta, Jodhbir S.
    [J]. PLOS ONE, 2013, 8 (06):
  • [4] Anterior Segment Optical Coherence Tomography Study of the Cornea and Anterior Segment in Adult Ethnic South Asian Indian Eyes
    Ang, Marcus
    Chong, Wesley
    Tay, Wan Ting
    Yuen, Leonard
    Wong, Tien Yin
    He, Ming-Guang
    Saw, Seang Mei
    Aung, Tin
    Mehta, Jodhbir S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (01) : 120 - 125
  • [5] [Anonymous], 2002, OPHTHALMOLOGY, V109, P651
  • [6] [Anonymous], 2000, J REFRACT SURG, V16, P349
  • [7] High-speed optical coherence tomography for management after laser in situ keratomileusis
    Avila, Mariana
    Li, Yan
    Song, Jonathan C.
    Huang, David
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) : 1836 - 1842
  • [8] Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS)
    Brandt, JD
    Beiser, JA
    Kass, MA
    Gordon, MO
    [J]. OPHTHALMOLOGY, 2001, 108 (10) : 1779 - 1788
  • [9] Reproducibility of Cornea Measurements in Anterior Segment OCT Images of Normal Eyes and Eyes with Bullous Keratopathy Analyzed with the Zhongshan Assessment Program
    Chan, Joy B.
    Yuen, Leonard H.
    Huang, Elaine H.
    Htoon, Hla M.
    He, Mingguang
    Aung, Tin
    Tan, Donald T.
    Mehta, Jodhbir S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) : 8884 - 8890
  • [10] Estimation accuracy of surgically induced astigmatism on the cornea when neglecting the posterior corneal surface measurement
    Cheng, Li-Sheng
    Tsai, Ching-Yao
    Tsai, Ray Jui-Fang
    Liou, Shiow-Wen
    Ho, Jau-Der
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (05) : 417 - 422