Simultaneous colorimetric detection of metallic salts contained in low explosives residue using a microfluidic paper-based analytical device (μPAD)

被引:30
|
作者
Chabaud, Kathryn R. [1 ]
Thomas, Jennifer L. [1 ]
Torres, Michelle N. [1 ]
Oliveira, Sheila [2 ]
McCord, Bruce R. [1 ]
机构
[1] Florida Int Univ, Dept Chem & Biochem, Modesto Madique Campus,11200 SW 8th St, Miami, FL 33199 USA
[2] State Univ Paraiba UEPB, Rua Baraunas,351 Bairro Univ, BR-58429500 Campina Grande, Paraiba, Brazil
关键词
Microfluidic paper-based analytical device (mu PAD); Low explosives; Improvised explosive device (IED); Colorimetric testing;
D O I
10.1016/j.forc.2018.03.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic paper-based analytical device (RAD) has been developed for the onsite determination of low explosives residues. The device is capable of simultaneous detection of a variety of metallic salts using colorimetric detection. The RAD was printed on chromatography paper with wax ink, allowing for the creation of a set of hydrophobic channels. Each channel contains a specific set of reagents that yields a color change upon interaction with a specific metal salt. The device is capable of performing six simultaneous tests, including the detection of metallic salts present in primer residues and pyrotechnic low explosive devices. Metals detected include lead, barium, antimony, iron, aluminum, zinc, and magnesium. Detection times were found to be less than 10 min and visual limits of detection ranged from 0.025 to 0.4 mu g of these metallic compounds. The resultant paper chip was then tested against various interferences and used to examine a number of different pyrotechnic compositions. This new device should prove useful in onsite detection of post-blast residues of pyrotechnics in the field due its portability and ease of use. (C) 2018 Published by Elsevier B.V.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [1] Simultaneous colorimetric detection of nephrolithiasis biomarkers using a microfluidic paper-based analytical device
    Janrod, Manassawee
    Srisa-Art, Monpichar
    Analytical Methods, 2022, 15 (06) : 752 - 761
  • [2] Simultaneous colorimetric detection of nephrolithiasis biomarkers using a microfluidic paper-based analytical device
    Janrod, Manassawee
    Srisa-Art, Monpichar
    ANALYTICAL METHODS, 2023, 15 (06) : 752 - 761
  • [3] Inkjet printed microfluidic paper-based analytical device (μPAD) for glucose colorimetric detection in artificial urine
    Han Zhang
    Ethan Smith
    Wei Zhang
    Anhong Zhou
    Biomedical Microdevices, 2019, 21
  • [4] Inkjet printed microfluidic paper-based analytical device (PAD) for glucose colorimetric detection in artificial urine
    Zhang, Han
    Smith, Ethan
    Zhang, Wei
    Zhou, Anhong
    BIOMEDICAL MICRODEVICES, 2019, 21 (03)
  • [5] Simultaneous Multiplexed Detection of Protein and Metal Ions by a Colorimetric Microfluidic Paper-based Analytical Device
    Xiong, Xiaolu
    Zhang, Junlin
    Wang, Zhou
    Liu, Chenchen
    Xiao, Wende
    Han, Junfeng
    Shi, Qingfan
    BIOCHIP JOURNAL, 2020, 14 (04) : 429 - 437
  • [6] Simultaneous Multiplexed Detection of Protein and Metal Ions by a Colorimetric Microfluidic Paper-based Analytical Device
    Xiaolu Xiong
    Junlin Zhang
    Zhou Wang
    Chenchen Liu
    Wende Xiao
    Junfeng Han
    Qingfan Shi
    BioChip Journal, 2020, 14 : 429 - 437
  • [7] Development of the simultaneous colorimetric enzymatic detection of sucrose, fructose and glucose using a microfluidic paper-based analytical device
    Aksorn, Jinakan
    Teepoo, Siriwan
    TALANTA, 2020, 207
  • [8] An enrichment system for glycoproteins using microfluidic paper-based analytical device with colorimetric detection
    Zhang, Jian
    Liu, Yi
    Peng, Jiayi
    Li, Wenjing
    Miao, Yanqing
    Liu, Chunye
    MICROCHEMICAL JOURNAL, 2024, 200
  • [9] A fabricated microfluidic paper-based analytical device (μPAD) for in situ rapid colorimetric detection of microorganisms in environmental water samples
    Ja-Young Kim
    Min-Kyeong Yeo
    Molecular & Cellular Toxicology, 2016, 12 : 101 - 109
  • [10] A fabricated microfluidic paper-based analytical device (μPAD) for in situ rapid colorimetric detection of microorganisms in environmental water samples
    Kim, Ja-Young
    Yeo, Min-Kyeong
    MOLECULAR & CELLULAR TOXICOLOGY, 2016, 12 (01) : 101 - 109