Evaluation of the Mechanical Behavior and Marginal Accuracy of Stock and Laser-Sintered Implant Abutments

被引:24
作者
Alonso-Perez, Raquel [1 ]
Bartolome, Jose F. [2 ]
Ferreiroa, Alberto [1 ]
Salido, Maria P. [1 ]
Pradies, Guillermo [1 ]
机构
[1] Univ Complutense Madrid, Dept Buccofacial Prostheses, Fac Odontol, Madrid, Spain
[2] CSIC, ICMM, C Sor Juana Ines de la Cruz 3, Madrid 28049, Spain
关键词
D O I
10.11607/ijp.5089
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to evaluate the marginal accuracy and mechanical behavior of implant-supported crowns restored with original stock abutments and nonoriginal computer-aided design/computer-assisted manufacture laser-sintered abutments. Materials and Methods: A total of 26 implants were divided in two groups (n = 13 each) as follows: implants connected to original stock abutments (OS) and implants connected to nonoriginal laser-sintered abutments (LS). Of these, 10 samples were cross-sectioned to measure the marginal accuracy under a scanning electron microscope. In addition, 16 samples were used to study the mechanical behavior. Two tests were performed: (7) static load and (2) dynamic load after thermocycling with artificial saliva. Results: OS exhibited the best marginal accuracy; however, the LS gap was within the clinically acceptable range of marginal discrepancy. No significant differences were found in the mechanical tests. Conclusions: Both abutments are acceptable alternatives to restore implants, although the original abutments showed better fit than nonoriginals.
引用
收藏
页码:136 / 138
页数:3
相关论文
共 5 条
[1]   Effect of Implant-Abutment Connection Design on Load Bearing Capacity and Failure Mode of Implants [J].
Dittmer, Stephanie ;
Dittmer, Marc Philipp ;
Kohorst, Philipp ;
Jendras, Michael ;
Borchers, Lothar ;
Stiesch, Meike .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (07) :510-516
[2]   Biological factors contributing to failures of osseointegrated oral implants (I). Success criteria and epidemiology [J].
Esposito, M ;
Hirsch, JM ;
Lekholm, U ;
Thomsen, P .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1998, 106 (01) :527-551
[3]   ANALYSIS OF THE MISFIT OF DENTAL IMPLANT-SUPPORTED PROSTHESES MADE WITH THREE MANUFACTURING PROCESSES [J].
Fernandez, Marc ;
Delgado, Luis ;
Molmeneu, Meritxell ;
Garcia, David ;
Rodriguez, Daniel .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (02) :116-123
[4]  
International Organization for Standardization, 2016, ISO 14801:2016
[5]   Evaluation of Retention of Cemented Laser-Sintered Crowns on Unmodified Straight Narrow Implant Abutments [J].
Kilicarslan, Mehmet Ali ;
Ozkan, Pelin .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) :381-387