Electroanalytical Determination of Cadmium(II) and Lead(II) Using an Antimony Nanoparticle Modified Boron-Doped Diamond Electrode

被引:145
作者
Toghill, Kathryn E. [1 ]
Xiao, Lei [1 ]
Wildgoose, Gregory G. [1 ]
Compton, Richard G. [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Dept Chem, Oxford OX1 3QZ, England
基金
英国工程与自然科学研究理事会;
关键词
Anodic stripping voltammetry; Antimony nanoparticles; Boron doped diamond; Cadmium determination; Lead determination; ANODIC-STRIPPING VOLTAMMETRY; BISMUTH-FILM ELECTRODES; GLASSY-CARBON ELECTRODES; MERCURY FILM; HEAVY-METALS; THIN-FILM; SURFACE; INTERFERENCES; CHLORIDE; COPPER;
D O I
10.1002/elan.200904547
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the simultaneous electroanalytical determination of Pb2+ and Cd2+ by linear sweep anodic stripping voltammetry (LSASV) using an antimony nanoparticle modified boron doped diamond (Sb-BDD) electrode. Sb deposition was performed in situ with the analytes, from a solution of 1 mg L-1 SbCl3 in 0.1 M HCl (pH 1). Pb2+ inhibited the detection of Cd2+ during simultaneous additions at the bare BDD electrode, whereas in the presence of antimony, both peaks were readily discernable and quantifiable over the linear range 50-500 mu g L-1. Ex situ AFM characterization of the BDD electrode after Sb deposition showed a distribution of nanoparticles ranging from 3 to 110 nm in height, and 8.5 to 506.5 nm in diameter across the electrode surface, which corresponded well to the low mass of Sb expected on the BDD with respect to the voltammetric data.
引用
收藏
页码:1113 / 1118
页数:6
相关论文
共 46 条
[1]   Simultaneous determination of nickel and cobalt in natural water and sediment samples on an in-situ plated mercury film electrode by adsorptive cathodic stripping voltammetry [J].
Adeloju, SB ;
Hadjichari, A .
ANALYTICAL SCIENCES, 1999, 15 (01) :95-100
[2]   Constant current cathodic stripping potentiometric determination of arsenic on a mercury film electrode in the presence of copper ions [J].
Adeloju, SB ;
Young, TM ;
Jagner, D ;
Batley, GE .
ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) :207-213
[3]  
[Anonymous], J APPL SCI
[4]  
Azim A.A., 1976, CORROS SCI, V16, P209
[5]   Electrochemical detection of trace concentrations of cadmium and lead with a boron-doped diamond electrode:: Effect of KCl and KNO3 electrolytes, interferences and measurement in river water [J].
Babyak, C ;
Smart, RR .
ELECTROANALYSIS, 2004, 16 (03) :175-182
[6]   PARAMETER EVALUATION FOR THE DETERMINATION OF SELENIUM BY CATHODIC STRIPPING VOLTAMMETRY AT THE HANGING MERCURY DROP ELECTRODE [J].
BALTENSPERGER, U ;
HERTZ, J .
ANALYTICA CHIMICA ACTA, 1985, 172 (JUN) :49-56
[7]   Cadmium detection via boron-doped diamond electrodes:: surfactant inhibited stripping voltarnmetry [J].
Banks, CE ;
Hyde, ME ;
Tomcík, P ;
Jacobs, R ;
Compton, RG .
TALANTA, 2004, 62 (02) :279-286
[8]  
Brett C.M.A., 1998, ELECTROANAL
[9]  
Brinic S, 2005, J NEW MAT ELECTR SYS, V8, P273
[10]   Acute toxicity of antimony chloride and its effects on oxygen consumption of common carp (Cyprinus carpio) [J].
Chen, L.-H. ;
Yang, J.-L. .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2007, 78 (06) :459-462