Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography -: Intraindividual comparison in an animal model

被引:37
作者
Lembcke, A
Wiese, TH
Schnorr, J
Wagner, S
Mews, J
Kroencke, TJ
Enzweiler, CNH
Hamm, B
Taupitz, M
机构
[1] Humboldt Univ, Inst Radiol, Klinikum Charite, Dept Radiol,Charite Med Sch, D-10098 Berlin, Germany
[2] Toshiba Med Syst, Neuss, Germany
关键词
electron beam CT; multislice spiral CT; coronary arteries;
D O I
10.1097/01.rli.0000123316.10765.6c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Comparison of coronary artery visualization by multislice spiral CT (MSCT) and electron-bearn CT (EBCT). Materials and Methods: Six minipigs underwent MSCT (collimation 4 X I mm, gantry rotation time 500 milliseconds, acquisition time per cardiac cycle 126 +/- 30 milliseconds) and EBCT (slice thickness 1.5 mm, acquisition time per scan 100 milliseconds). Visualized vessel length and contour sharpness was measured, contrast-to-noise ratios were calculated, and the frequency of motion artifacts were evaluated. Results: MSCT depicted significantly longer segments of the coronary tree than EBCT (length: 248.8 vs. 222.8 mm; P < 0.05), delineated the vessel contours more sharply (slope of density curves: 219.2 vs. 160.2 DeltaHU/mm; P < 0.05), and had a higher contrast-to-noise ratio (13.4 vs. 7.3; P < 0.05). The frequency of motion artifacts did not differ between both modalities (94.7% vs. 95.7% of visualized vessel length; P > 0.05). Conclusions: Because its higher spatial resolution and lower image noise, MSCT seems to be superior to EBCT in the visualization of the coronary arteries. Despite different temporal resolutions motion artifacts seem to be similar with both modalities.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 27 条
[1]   Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]   Detection of coronary artery stenoses with multislice helical CT angiography [J].
Becker, CR ;
Knez, A ;
Leber, A ;
Treede, H ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) :750-755
[4]   New coronary imaging techniques: what to expect? [J].
de Feyter, PJ ;
Nieman, K .
HEART, 2002, 87 (03) :195-197
[5]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[6]   Evaluation of reconstruction windows for multislice computed tomography in quantification of coronary calcium [J].
Gerber, TC ;
O'Brien, PC ;
Pastor, K ;
Kuzo, RS ;
Blackshear, JL ;
Morin, RL .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :108-118
[7]   Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography [J].
Gerber, TC ;
Kuzo, RS ;
Lane, GE ;
O'Brien, PC ;
Karstaedt, N ;
Morin, RL ;
Safford, RE ;
Blackshear, JL ;
Pietan, JH .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (01) :62-69
[8]   Current results and new developments of coronary angiography with use of contrast-enhanced computed tomography of the heart [J].
Gerber, TC ;
Kuzo, RS ;
Karstaedt, N ;
Lane, GE ;
Morin, RL ;
Sheedy, PF ;
Safford, RE ;
Blackshear, JL ;
Pietan, JH .
MAYO CLINIC PROCEEDINGS, 2002, 77 (01) :55-71
[9]   Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection [J].
Giesler, T ;
Baum, U ;
Ropers, D ;
Ulzheimer, S ;
Wenkel, E ;
Mennicke, M ;
Bautz, W ;
Kalender, WA ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) :911-916
[10]   Coronary artery calcium scoring using multicardiac computed tomography [J].
Horiguchi, J ;
Nakanishi, T ;
Tamura, A ;
Ito, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (06) :880-885