Indoor environmental quality of classrooms in Southern European climate

被引:85
作者
Almeida, Ricardo M. S. F. [1 ,2 ]
de Freitas, Vasco Peixoto [2 ]
机构
[1] Sch Technol & Management, Polytech Inst Viseu, Dept Civil Engn, P-3504510 Viseu, Portugal
[2] Univ Porto, Fac Engn, Dept Civil Engn, Lab Bldg Phys, P-4200465 Oporto, Portugal
关键词
Carbon dioxide concentration; Indoor environmental quality; Relative humidity; School building retrofit; Temperature; Ventilation rates; CARBON-DIOXIDE CONCENTRATION; AIR-QUALITY; VENTILATION RATES; THERMAL COMFORT; HEALTH SYMPTOMS; SCHOOLS; PERFORMANCE; ENERGY; IMPACT; CO2;
D O I
10.1016/j.enbuild.2014.06.020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The indoor environmental quality within a classroom is linked to the health, comfort and performance of students. It is well established that there are classroom environments where indoor environmental quality is poor. Therefore, the rehabilitation of school buildings is assumed as an appropriate strategy. Consequently, some countries have sponsored nationwide programs for the rehabilitation of school buildings, whose result has been, in some cases, other than the expected. Classrooms performance in service conditions must be evaluated and, from the results, optimized solutions should be established and carefully designed and executed to have the desired effect. Thus, a research project was defined, aiming to assess the impact of retrofit on the indoor environmental quality of school buildings. The methodology used included the in situ measurement of temperature, relative humidity, carbon dioxide concentration and ventilation rates. A total of 24 classrooms of 9 school buildings (2 non-retrofitted and 7 recently retrofitted) were studied. A long term monitoring was defined with three measurement campaigns: winter, mid-season and summer conditions, each with three weeks length. The results confirmed that non-retrofitted schools need to improve their indoor environmental conditions and in retrofitted buildings mechanical ventilation systems are not being used, with important consequences on the indoor air quality. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 140
页数:14
相关论文
共 45 条
  • [11] Ventilation rates in schools and pupils' performance
    Bako-Biro, Zs.
    Clements-Croome, D. J.
    Kochhar, N.
    Awbi, H. B.
    Williams, M. J.
    [J]. BUILDING AND ENVIRONMENT, 2012, 48 : 215 - 223
  • [12] Calice C., 2012, SUSTAINABLE CITY
  • [13] Ventilation rates in schools
    Clements-Croome, D. J.
    Awbi, H. B.
    Bako-Biro, Zs
    Kochhar, N.
    Williams, M.
    [J]. BUILDING AND ENVIRONMENT, 2008, 43 (03) : 362 - 367
  • [14] Coley D. A., 2002, International Journal of Ventilation, V1, P45, DOI DOI 10.1080/14733315.2002.11683621
  • [15] Application of a developed adaptive model in the evaluation of thermal comfort in ventilated kindergarten occupied spaces
    Conceicao, Eusebio Z. E.
    Gomes, Joao M. M.
    Antao, Nuno H.
    Lucio, Ma Manuela J. R.
    [J]. BUILDING AND ENVIRONMENT, 2012, 50 : 190 - 201
  • [16] Conceicao EZE., 2006, International Journal of Ventilation, V5, P259, DOI DOI 10.1080/14733315.2006.11683743
  • [17] Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information
    Daisey, JM
    Angell, WJ
    Apte, MG
    [J]. INDOOR AIR, 2003, 13 (01) : 53 - 64
  • [18] De Dear R., 1998, Build. Eng., V104, P145
  • [19] Measured and perceived environmental comfort: Field monitoring in an Italian school
    De Giuli, Valeria
    Zecchin, Roberto
    Corain, Livio
    Salmaso, Luigi
    [J]. APPLIED ERGONOMICS, 2014, 45 (04) : 1035 - 1047
  • [20] Indoor environmental quality and pupil perception in Italian primary schools
    De Giuli, Valeria
    Da Pos, Osvaldo
    De Carli, Michele
    [J]. BUILDING AND ENVIRONMENT, 2012, 56 : 335 - 345