New tools for Wilson's disease diagnosis: exchangeable copper fraction

被引:61
作者
Wohnant, France [1 ,2 ]
Djebrani-Oussedik, Nouzha [1 ,3 ]
Poujois, Aurelia [1 ,2 ]
机构
[1] Lariboisiere Univ Hosp, AP HP, Natl Reference Ctr Wilsons Dis, Paris, France
[2] Lariboisiere Univ Hosp, AP HP, Neurol Dept, Paris, France
[3] Lariboisiere Univ Hosp, AP HP, Toxicol Lab, Paris, France
关键词
Wilson's disease (WD); diagnosis; relative exchangeable copper (REC); exchangeable copper; cupric markers; CERULOPLASMIN-BOUND COPPER; CLINICAL-PRACTICE; SERUM; HEALTHY; ASSAY; ELEMENTS;
D O I
10.21037/atm.2019.03.02
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Wilson's disease (WD) biochemical markers continue to evolve. Classical tests [serum copper, serum ceruloplasmin (Cp), urinary copper] have their own limits, and they are often insufficient to diagnose or exclude WD. So, calculated estimation of copper that is not bound to Cp has been proposed, but it is flawed. Therefore, we focused our research on a direct measurement of serum copper labile fraction. Exchangeable copper (CuEXC) offers a correct view of the free copper overload. It provides information on the spread and severity of WD. Relative exchangeable copper (REC) (percentage of exchangeable to total serum copper) that appreciates the toxic fraction of copper in blood is an excellent biomarker for WD diagnosis. These two tests are reliable and non-invasive. They give rapid answers for an appropriate diagnosis and make possible to start the treatment quickly without waiting for the result of the genetic tests. As early diagnosis and treatment are the keystones of successful management of patients with WD, different teams have already applied these tests in a routine framework to a large number of patients.
引用
收藏
页数:9
相关论文
共 45 条
[1]  
[Anonymous], EMC BIOL MED PARIS
[2]  
[Anonymous], WORLD J GASTROENTERO
[3]  
[Anonymous], J HEPATOL
[4]   Structure to function relationships in ceruloplasmin: a 'moonlighting' protein [J].
Bielli, P ;
Calabrese, L .
CELLULAR AND MOLECULAR LIFE SCIENCES, 2002, 59 (09) :1413-1427
[5]   Analytical variables affecting exchangeable copper determination in blood plasma [J].
Buckley, Wayne T. ;
Vanderpool, Richard A. .
BIOMETALS, 2008, 21 (06) :601-612
[6]  
Cztonkowska A, 2007, NEUROL NEUROCHIR POL, V41, P1
[7]   How reliable and robust are current biomarkers for copper status? [J].
Danzeisen, Ruth ;
Araya, Magdalena ;
Harrison, Brenda ;
Keen, Carl ;
Solioz, Marc ;
Thiele, Dennis ;
McArdle, Harry J. .
BRITISH JOURNAL OF NUTRITION, 2007, 98 (04) :676-683
[8]   Relative exchangeable copper: A new highly sensitive and highly specific biomarker for Wilson's disease diagnosis [J].
El Balkhi, Souleiman ;
Trocello, Jean-Marc ;
Poupon, Joel ;
Chappuis, Philippe ;
Massicot, France ;
Girardot-Tinant, Nadege ;
Woimant, France .
CLINICA CHIMICA ACTA, 2011, 412 (23-24) :2254-2260
[9]   Determination of ultrafiltrable and exchangeable copper in plasma: stability and reference values in healthy subjects [J].
El Balkhi, Souleiman ;
Poupon, Joel ;
Trocello, Jean-Marc ;
Leyendecker, Angelique ;
Massicot, France ;
Galliot-Guilley, Martine ;
Woimant, France .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (05) :1477-1484
[10]  
Erel O, 1998, CLIN CHEM, V44, P2313