Mouthguard Biomechanics for Protecting Dental Implants from Impact: Experimental and Finite Element Impact Analysis

被引:17
作者
Carvalho, Valessa F. [1 ]
Soares, Priscilla B. F. [2 ]
Verissimo, Crisnicaw [3 ]
Pessoa, Roberto S. [1 ]
Versluis, Antheunis [4 ]
Soares, Carlos J. [1 ]
机构
[1] Univ Fed Uberlandia, Biomech Res Grp, Sch Dent, Dept Operat Dent & Dent Mat, Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Biomech Res Grp, Sch Dent, Dept Periodont & Implantol, Uberlandia, MG, Brazil
[3] Univ Uberaba, Sch Dent, Uberaba, MG, Brazil
[4] Univ Tennessee, Hlth Sci Ctr, Coll Dent, Dept Biosci Res, Memphis, TN 38163 USA
关键词
abutment design; dental implant; dental implant-abutment connection; ethylene vinyl acetate copolymer; finite element analysis; mouthguards; single-tooth dental implant; strain; stress; CONNECTION DESIGNS; EVA MOUTHGUARDS; MORSE TAPER; CUSTOM-MADE; TRAUMA; DENTISTRY; STRENGTH; TESTS; MODEL;
D O I
10.11607/jomi.5803
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to evaluate mouthguard shock absorption ability, strain, and stress generation during impact on dental implants placed in the anterior maxilla. The mouthguard material was also characterized. Materials and Methods: Sixty experimental models were created and divided into six groups (n = 10): implant type, external hexagon (EH) and Morse taper (MT); without and with two mouthguards (MTG), EVA custom-fitted (Ct-MTG) and standard self-adapted (St-MTG). The Shore A hardness, EVA sheet and mouthguard thickness, and elastic modulus were measured to characterize the mouthguard material. A strain gauge was attached to the palatal surface of the implant abutment, which was subjected to an impact test. Distortion of the abutment and implant was determined after impact from centroid displacements in standardized radiographic images. Two-dimensional finite element models were created to represent the six groups and were submitted to nonlinear dynamic impact analysis. The data were statistically analyzed using analysis of variance (ANOVA) and Tukey test (alpha = .05). Results: Ct-MTG resulted in higher Shore A hardness (P < .001). After the heat-forming process, the St-MTG maintained the original thickness, but the Ct-MTG thickness had decreased. The elastic modulus of EVA was 18.1 +/- 0.5 MPa. The mouthguard presence reduced strain values significantly (P < .001), particularly for Ct-MTG. There was no significant difference between implant connection types EH and MT (P = .547). Conclusion: The external hexagon abutment resulted in higher stress and micro-displacement values. The mouthguard was able to absorb 40% to 46% of the energy caused by the impact on the dental implant.
引用
收藏
页码:335 / 343
页数:9
相关论文
共 32 条
[1]   Trauma to an osseointegrated anterior dental implant: a case report [J].
Allen, EM ;
Allen, PF .
DENTAL TRAUMATOLOGY, 2006, 22 (01) :44-47
[2]  
[Anonymous], 2017, A276A276M17 ASTM
[3]   Influences of Internal Tapered Abutment Designs on Bone Stresses Around a Dental Implant: Three-Dimensional Finite Element Method With Statistical Evaluation [J].
Chu, Chun-Ming ;
Huang, Heng-Li ;
Hsu, Jui-Ting ;
Fuh, Lih-Jyh .
JOURNAL OF PERIODONTOLOGY, 2012, 83 (01) :111-118
[4]   Implant treatment choice after extraction of a vertically fractured tooth. A proposal for a clinical classification of bony defects based on a systematic review of literature [J].
Corbella, Stefano ;
Taschieri, Silvio ;
Samaranayake, Lakshman ;
Tsesis, Igor ;
Nemcovsky, Carlos ;
Del Fabbro, Massimo .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (08) :946-956
[5]   Trauma to an implant-supported crown that was saved by the fixation screw: a case report [J].
den Hartog, Laurens ;
Meijer, Henny J. A. ;
Stellingsma, Kees ;
Santing, Hendrik J. ;
Raghoebar, Gerry M. .
DENTAL TRAUMATOLOGY, 2010, 26 (04) :366-369
[6]   External and occlusal trauma to dental implants and a case report [J].
Flanagan, D .
DENTAL TRAUMATOLOGY, 2003, 19 (03) :160-164
[7]   Comparison of usability properties of custom-made and standard self-adapted mouthguards [J].
Gawlak, Dominika ;
Mierzwinska-Nastalska, Elzbieta ;
Manka-Malara, Katarzyna ;
Kaminski, Tomasz .
DENTAL TRAUMATOLOGY, 2014, 30 (04) :306-311
[8]   Influence of bone insertion level of the implant on the fracture strength of different connection designs: an in vitro study [J].
Gehrke, Sergio Alexandre ;
dos Santos Vianna, Miriam Souza ;
Dedavid, Berenice Anina .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) :715-720
[9]   Application of finite element analysis in implant dentistry: A review of the literature [J].
Geng, JP ;
Tan, KBC ;
Liu, GR .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (06) :585-598
[10]   Biomechanical aspects of prosthetic implant-borne reconstructions [J].
Glantz, POJ ;
Nilner, K .
PERIODONTOLOGY 2000, 1998, 17 :119-124