Reconstruction of Inferior Orbital Wall Fractures Using Bone Fragments

被引:6
作者
Kim, Jin Tae [1 ]
Lee, Soo-Hyang [1 ]
机构
[1] Inje Univ, Ilsan Paik Hosp, Dept Plast & Reconstruct Surg, Goyang 411706, South Korea
关键词
Absorbable implants; autologous bone fragments; blowout fracture; fibrin glue; POROUS POLYETHYLENE; FLOOR FRACTURES; MESH; TITANIUM; IMPLANTS; PLATE;
D O I
10.1097/SCS.0000000000002090
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction:Various materials have been used as implants in orbital floor fractures. The fractured bone fragments, however, are not usually used because of their small size and delicate characteristics. To overcome this limitation, the authors used autologous bone fragments combined with fibrin glue and an absorbable plate to repair inferior orbital wall fractures.Methods:Thirty-four patients with orbital floor fractures treated in a single center from January 2013 to September 2014 were prospectively evaluated. Patients' demographic characteristics, clinical signs and symptoms, physical examination findings, postoperative complications, and preoperative and postoperative computed tomography findings were assessed. Fracture repair by a transconjunctival approach in which bone fragments were merged with fibrin glue and an absorbable plate was performed in all the patients.Results:Postoperative computed tomography showed good orbital fracture reduction and soft tissue restoration in all the patients. Five patients developed postoperative diplopia; however, this symptom resolved spontaneously. Exophthalmometry showed that the degree of enophthalmos had improved significantly.Conclusion:Based on the results of this study, the combination of autologous bone fragments and absorbable mesh appears to be a safe and feasible option for the reconstruction of orbital floor fractures.
引用
收藏
页码:2412 / 2414
页数:3
相关论文
共 15 条
[1]   A comparative study of 2 implants used to repair inferior orbital wall bony defects: Autogenous bone graft versus bioresorbable poly-L/DL-lactide [P(L/DL)LA 70/30] plate [J].
Al-Sukhun, J ;
Lindqvist, C .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (07) :1038-1048
[2]   Internal fixation in trapdoor-type orbital blowout fracture [J].
Burm, JS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2005, 116 (04) :962-970
[3]  
Burnstine Michael A, 2003, Curr Opin Ophthalmol, V14, P236, DOI 10.1097/00055735-200310000-00002
[4]   Orbital Wall Reconstruction with Titanium Mesh: Retrospective Study of 24 Patients [J].
Gabrielli, Mario Francisco ;
Monnazzi, Marcelo Silva ;
Passeri, Luis Augusto ;
Carvalho, Waldner Ricardo ;
Gabrielli, Marisa ;
Hochuli-Vieira, Eduardo .
CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2011, 4 (03) :151-156
[5]   Use of porous polyethylene with embedded titanium in orbital reconstruction: A review of 106 patients [J].
Garibaldi, Daniel C. ;
Nicholas, T. Iliff ;
Grant, Michael P. ;
Merbs, Shannath L. .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 23 (06) :439-444
[6]   Combined Use of Titanium Mesh and Resorbable PLLA-PGA Implant in the Treatment of Large Orbital Floor Fractures [J].
Gonzalez Magana, Fernando ;
Menendez Arzac, Rodrigo ;
De Hilario Aviles, Laura .
JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (06) :1991-1995
[7]   Open Reduction in Trapdoor-Type Blowout Fractures Using Absorbable Mesh Plates [J].
Kim, Young Jin ;
Choi, Seung Ho ;
Jun, Young Joon ;
Seo, Byung Chul .
JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (06) :2264-2267
[8]   Effectiveness of operative treatment of internal orbital wall fracture with polydioxanone implant [J].
Kontio, R ;
Suuronen, R ;
Salonen, O ;
Paukku, P ;
Konttinen, YT ;
Lindqvist, C .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 30 (04) :278-285
[9]   Treatment of Orbital Fractures: Evaluation of Surgical Techniques and Materials for Reconstruction [J].
Nowinski, Daniel ;
Messo, Elias ;
Hedlund, Anders .
JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (04) :1033-1037
[10]   Functional outcome after surgical treatment of orbital floor fractures [J].
Poeschl, Paul W. ;
Baumann, Arnulf ;
Dorner, Guido ;
Russmueller, Guenter ;
Seemann, Rudolf ;
Fabian, Ferenc ;
Ewers, Rolf .
CLINICAL ORAL INVESTIGATIONS, 2012, 16 (04) :1297-1303