The Influence of Different Force and Pressure Measuring Transducers on Lower Extremity Kinematics Measured During Running

被引:24
作者
Sinclair, Jonathan [1 ]
Hobbs, Sarah J. [1 ]
Taylor, Paul J. [2 ]
Currigan, Graham [1 ]
Greenhalgh, Andrew [3 ]
机构
[1] Univ Cent Lancashire, Div Sport Exercise & Nutr Sci, Preston PR1 2HE, Lancs, England
[2] Univ Cent Lancashire, Sch Psychol, Preston PR1 2HE, Lancs, England
[3] Middlesex Univ, London Sport Inst, London N17 8HR, England
关键词
motion capture; targeting; running; gait modifications; GROUND REACTION FORCE; VARIABILITY; GAIT;
D O I
10.1123/jab.2012-0238
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In running analyses where both kinetic and kinematic information is recorded, participants are required to make foot contact with a force and/or pressure measuring transducer. Problems arise if participants modify their gait patterns to ensure contact with the device. There is currently a paucity of research investigating the influence of different underfoot kinetic measuring devices on 3-dimensional kinematics of running. Fifteen participants ran at 4.0 m/s in four different conditions: over a floor embedded force plate, Footscan, Matscan, and with no device. Three-dimensional angular kinematic parameters were collected using an eight camera motion analysis system. Hip, knee, and ankle joint kinematics were contrasted using repeated-measures ANOVAs. Participants also rated their subjective comfort in striking each of the three force measuring devices. Significant differences from the uninhibited condition were observed using the Footscan and Matscan in all three planes of rotation, whereas participants subjectively rated the force plate significantly more comfortable than either the Footscan/Matscan devices. The findings of the current investigation therefore suggest that the disguised floor embedded force plate offers the most natural running condition. It is recommended that analyses using devices such as the Footscan/Matscan mats overlying the laboratory surface during running should be interpreted with caution.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 10 条
[1]   PREDICTION OF HIP-JOINT CENTER LOCATION FROM EXTERNAL LANDMARKS [J].
BELL, AL ;
BRAND, RA ;
PEDERSEN, DR .
HUMAN MOVEMENT SCIENCE, 1989, 8 (01) :3-16
[2]   Ground reaction forces and kinematics in distance running in older-aged men [J].
Bus, SA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (07) :1167-1175
[3]   POSITION AND ORIENTATION IN-SPACE OF BONES DURING MOVEMENT - ANATOMICAL FRAME DEFINITION AND DETERMINATION [J].
CAPPOZZO, A ;
CATANI, F ;
DELLA CROCE, U ;
LEARDINI, A .
CLINICAL BIOMECHANICS, 1995, 10 (04) :171-178
[4]   The variability in running gait caused by force plate targeting [J].
Challis, JH .
JOURNAL OF APPLIED BIOMECHANICS, 2001, 17 (01) :77-83
[5]   Local dynamic stability versus kinematic variability of continuous overground and treadmill walking [J].
Dingwell, JB ;
Cusumano, JP ;
Cavanagh, PR ;
Sternad, D .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (01) :27-32
[6]   VISUAL GUIDANCE TO FORCE PLATES DOES NOT INFLUENCE GROUND REACTION FORCE VARIABILITY [J].
GRABINER, MD ;
FEUERBACH, JW ;
LUNDIN, TM ;
DAVIS, BL .
JOURNAL OF BIOMECHANICS, 1995, 28 (09) :1115-1117
[7]   A comparison of overground and treadmill running for measuring the three-dimensional kinematics of the lumbo-pelvic-hip complex [J].
Schache, AG ;
Blanch, PD ;
Rath, DA ;
Wrigley, TV ;
Starr, R ;
Bennell, KL .
CLINICAL BIOMECHANICS, 2001, 16 (08) :667-680
[8]   Three-dimensional kinematic comparison of treadmill and overground running [J].
Sinclair, Jonathan ;
Richards, Jim ;
Taylor, Paul J. ;
Edmundson, Christopher J. ;
Brooks, Darrell ;
Hobbs, Sarah J. .
SPORTS BIOMECHANICS, 2013, 12 (03) :272-282
[9]   Kinematics and electromyography of lower limb muscles in overground and treadmill running [J].
Wank, V ;
Frick, U ;
Schmidtbleicher, D .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1998, 19 (07) :455-461
[10]   The effect of visual targeting on ground reaction force and temporospatial parameters of gait [J].
Wearing, SC ;
Urry, SR ;
Smeathers, JE .
CLINICAL BIOMECHANICS, 2000, 15 (08) :583-591