Promising Detector Concepts to Advance Coincidence Time Resolution for Time-of-Flight Positron Emission Tomography

被引:1
|
作者
Levin, C. S. [1 ,2 ,3 ,4 ]
机构
[1] Stanford Univ, James H Clark Ctr, Dept Radiol, 318 Campus Dr, Stanford, CA 94305 USA
[2] Stanford Univ, James H Clark Ctr, Dept Phys, 318 Campus Dr, Stanford, CA 94305 USA
[3] Stanford Univ, James H Clark Ctr, Dept Elect Engn, 318 Campus Dr, Stanford, CA 94305 USA
[4] Stanford Univ, James H Clark Ctr, Dept Bioengn, 318 Campus Dr, Stanford, CA 94305 USA
关键词
time-of-flight positron emission tomography (TOF-PET); coincidence time resolution (CTR); scintillation detectors; optical modulations;
D O I
10.12693/APhysPolA.142.422
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In this paper, we describe design considerations and promising detector technologies for time-of-flight positron emission tomography (TOF-PET). During a positron emission tomography scan, TOF-PET enables positron annihilation events to be positioned closer to their true origin along system response lines, thus facilitating improved reconstructed image signal-to-noise ratio, which has benefits such as better disease visualization and quantification, lower injected dose, and/or lower study duration. The degree of this image signal-to-noise ratio boost is determined by the annihilation photon pair coincidence time resolution of the detector system. Thus, there has been much research and development to advance detector coincidence time resolution, which is the foundation for future TOF-PET system designs. But when considering novel TOF-PET detector designs, it is important to select approaches that enhance coincidence time resolution without a tradeoff of decreasing detection efficiency (e.g., employing thin or low-density detector materials or low intra- or inter-module packing fraction, etc.). One might even argue that high coincidence detection efficiency (a.k.a. sensitivity) is the primary goal of any new positron emission tomography system design. In this paper, we will briefly discuss fundamental limitations on positron emission tomography coincidence time resolution using scintillation detectors and describe new detector configurations and electronic readout designs that attempt to address those constraints and achieve as low as 100 ps coincidence time resolution without compromising overall detection efficiency. We also concisely describe an innovative, non-scintillation-based, fast detection concept, which borrows ideas from the field of optics and could, in theory, achieve similar to 1 ps coincidence time resolution. If successful, these technologies will lead to next-generation systems that enhance TOF-PET's ability to visualize and quantify disease.
引用
收藏
页码:422 / 427
页数:6
相关论文
共 50 条
  • [1] A New Direction to Explore to Advance Coincidence Time Resolution for Time-of-Flight Positron Emission Tomography
    Tao, L.
    Levin, C. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S305 - S306
  • [2] Assessment of a high-resolution candidate detector for prostate time-of-flight positron emission tomography
    Cosentino, Luigi
    Finocchiaro, Paolo
    Pappalardo, Alfio
    Garibaldi, Franco
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (11):
  • [3] A Method for Measuring Time-of-Flight Resolution of Positron Emission Tomography Scanner
    Niu, Xiaofeng
    Ye, Hongwei
    Gagnon, Daniel
    Wang, Wenli
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2643 - 2646
  • [4] Instrumentation for Time-of-Flight Positron Emission Tomography
    Ullah M.N.
    Pratiwi E.
    Cheon J.
    Choi H.
    Yeom J.Y.
    Nuclear Medicine and Molecular Imaging, 2016, 50 (2) : 112 - 122
  • [5] Single Channel Optimization for an Endoscopic Time-of-Flight Positron Emission Tomography Detector
    Garutti, Erika
    Gadow, Karsten
    Goettlich, Martin
    Silenzi, Alessandro
    Xu, Chen
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 54 - 58
  • [6] Pilot study of timing performance for time-of-flight positron emission tomography detector
    Liu, Jun-Hui
    Li, Dao-Wu
    Zhang, Zhi-Ming
    Liao, Yan-Fei
    Huang, Xian-Chao
    Wang, Pei-Lin
    Chen, Yan
    Yun, Ming-Kai
    Feng, Bao-Tong
    Shuai, Lei
    Wang, Bao-Yi
    Zhang, Tian-Bao
    Wei, Long
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2011, 45 (12): : 1522 - 1526
  • [7] EFFECT OF THE SOFTWARE COINCIDENCE TIMING WINDOW IN TIME-OF-FLIGHT ASSISTED POSITRON EMISSION TOMOGRAPHY
    YAMAMOTO, M
    FICKE, DC
    TERPOGOSSIAN, MM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (01) : 711 - 714
  • [8] TIME-OF-FLIGHT POSITRON EMISSION TOMOGRAPHY WITH RADIOFREQUENCY PHOTOTUBE
    Margaryan, Amur
    Kakoyan, Vanik
    Knyazyan, Svetlana
    WORKSHOP ON TIMING DETECTORS: ELECTRONICS, MEDICAL AND PARTICLE PHYSICS APPLICATIONS, 2010, 4 (01): : 107 - 112
  • [9] FEASIBILITY OF TIME-OF-FLIGHT RECONSTRUCTION IN POSITRON EMISSION TOMOGRAPHY
    MULLANI, NA
    MARKHAM, J
    TERPOGOSSIAN, MM
    JOURNAL OF NUCLEAR MEDICINE, 1980, 21 (11) : 1095 - 1097
  • [10] High-resolution image reconstruction method for time-of-flight positron emission tomography
    Yamaya, T
    Obi, T
    Yamaguchi, M
    Ohyama, N
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3125 - 3134