A novel three-dimensional non-destructive beam monitor named pi(3) was conceived, realized and tested. It is based on a thin aluminum foil coated with P47 scintillating material mounted on a support, together with a miniaturized CCD camera, both moving along the beam axis. This detector allows reconstructing of the beam distribution along the beam path, providing either an on-line video or a graphical reconstruction of the beam envelope in 3D. The pi(3) detector is a general-purpose instrument suitable for any ion accelerator facility. As it is constructed with non-magnetic materials, it can be used to investigate the behavior of the beam inside beam optics components such as magnets. In this paper, we report the development of the first prototype of the pi(3) detector, its associated software and the results of the beam tests performed at the Bern medical cyclotron laboratory.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 15 条
[1]  
[Anonymous], 2019, P 8 INT BEAM INSTR C
[2]   A detector based on silica fibers for ion beam monitoring in a wide current range [J].
Auger, M. ;
Braccini, S. ;
Carzaniga, T. S. ;
Ereditato, A. ;
Nesteruk, K. P. ;
Scampoli, P. .
JOURNAL OF INSTRUMENTATION, 2016, 11
[3]   Low current performance of the Bern medical cyclotron down to the pA range [J].
Auger, M. ;
Braccini, S. ;
Ereditato, A. ;
Nesteruk, K. P. ;
Scampoli, P. .
MEASUREMENT SCIENCE and TECHNOLOGY, 2015, 26 (09)
[4]  
Belver-Aguilar C., 2020, P IBIC2020 REM BRAZ
[5]  
Braccini S., 2019, P INT C CYCL THEIR A
[6]  
Braccini S., 2011, P IPAC2011, P3618
[7]   The New Bern PET Cyclotron, Its Research Beam Line, And The Development Of An Innovative Beam Monitor Detector [J].
Braccini, Saverio .
APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2013, 1525 :144-150
[8]  
Dehnel M., 2013, P CYC2013
[9]  
Gsponer A., 2019, THESIS
[10]   A beam monitoring and validation system for continuous line scanning in proton therapy [J].
Klimpki, G. ;
Psoroulas, S. ;
Bula, C. ;
Rechsteiner, U. ;
Eichin, M. ;
Weber, D. C. ;
Lomax, A. ;
Meer, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (15) :6126-6143