The determination of relative path length as a measure for tortuosity in compacts using image analysis

被引:56
作者
Wu, Yu San
van Vliet, Lucas J.
Frijlink, Henderik W.
van der Voort Maarschalk, Kees
机构
[1] Univ Groningen, Dept Pharmaceut Technol & Biopharm, NL-9713 AV Groningen, Netherlands
[2] Delft Univ Technol, Fac Sci Appl, Dept Imaging Sci & Technol, Quantitat Imaging Grp, Delft, Netherlands
[3] NV Organon, Dept Pharmaceut, Oss, Netherlands
关键词
imaging; tablets; anisotropy; porosity; pore structure; sodium chloride;
D O I
10.1016/j.ejps.2006.05.006
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Tortuosity is defined as the ratio of the actual path length from start to goal through the pores to the Euclidean distance (shortest linear distance). However, traditional methods to calculate tortuosity, such as the calculation of tortuosity out of the results from dissolution experiments, do not determine path length directly In this paper we describe the application of image analysis for direct measurement of path length in order to obtain quantitative information on tortuosity. Several planes in cubic sodium chloride compacts, made by uni-axial compression, were imaged using scanning electron microscopy (SEM). In these images the average path length from top-to-bottom and from left-to-right was calculated, using the gray-weighted distance transform (GDT). As the direct, straight forward path was defined as having a length of unity, the relative path length could be taken as a quantitative measure for the tortuosity. The relative path length through the pores was found to be 1.4-1.6 and the relative path length over the grains was significantly lower (1.0-1.2). In most cases, the relative path length through the pores was significantly higher for the compacts containing small particles than for the compacts made of large particles. The relative path length was also dependent on the direction of the measurement, i.e. in the direction of compression of the compact or perpendicular to it. This indicates anisotropy in structure with the pores preferentially oriented in the direction of compression. It was concluded that this method is a valuable tool for the determination of path length in compacts as a direct measure for tortuosity. It can also be used to evaluate the anisotropy' in structure. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 12 条
[1]  
ANDO T, 1983, CHEM PHARM BULL, V31, P2045
[2]   INVESTIGATION OF FACTORS INFLUENCING RELEASE OF SOLID DRUG DISPERSED IN INERT MATRICES .2. QUANTITATION OF PROCEDURES [J].
DESAI, SJ ;
SINGH, P ;
SIMONELLI, AP ;
HIGUCHI, WI .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1966, 55 (11) :1224-+
[3]   INVESTIGATION OF FACTORS INFLUENCING RELEASE OF SOLID DRUG DISPERSED IN INERT MATRICES [J].
DESAI, SJ ;
SIMONELL.AP ;
HIGUCHI, WI .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1965, 54 (10) :1459-&
[4]   RELEASE OF HIGHLY WATER-SOLUBLE MEDICINAL COMPOUNDS FROM INERT, HETEROGENEOUS MATRICES .1. PHYSICAL MIXTURE [J].
FOSTER, TP ;
PARROTT, EL .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1990, 79 (09) :806-810
[5]   Strength anisotropy in cold compacted ductile and brittle powders [J].
Galen, S ;
Zavaliangos, A .
ACTA MATERIALIA, 2005, 53 (18) :4801-4815
[6]  
Martin A.N., 1993, PHYS PHARM PHYS CHEM, P337
[7]  
Papadokostaki KG, 1998, J APPL POLYM SCI, V67, P277, DOI 10.1002/(SICI)1097-4628(19980110)67:2<277::AID-APP10>3.0.CO
[8]  
2-W
[9]   SHADING FROM SHAPE, THE EIKONAL EQUATION SOLVED BY GRAY-WEIGHTED DISTANCE TRANSFORM [J].
VERBEEK, PW ;
VERWER, BJH .
PATTERN RECOGNITION LETTERS, 1990, 11 (10) :681-690
[10]  
Webb PA., 2001, INTRO PHYS CHARACTER