Use of the Univent System tube(R) for difficult intubation and for achieving one-lung anaesthesia

被引:14
作者
GarciaAguado, R [1 ]
Mateo, EM [1 ]
Onrubia, VJ [1 ]
Bolinches, R [1 ]
机构
[1] HOSP GEN UNIV,DEPT ANAESTHESIA,VALENCIA,SPAIN
关键词
difficult intubation; one-lung ventilation; thoracic surgery; Univent tube;
D O I
10.1111/j.1399-6576.1996.tb04526.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: One-lung ventilation in major thoracic surgery is the most commonly accepted technique, not only for surgery on the lung but also in procedures involving the oesophagus, mediastinum and thoracic aorta. Conventional double-lumen tubes may sometimes be difficult to place correctly in patients in whom intubation is difficult. In such cases, the Univent System tube(R) may be of help. It has a curved movable blocker of small calibre, and is designed to slide inside the bronchial tree and occlude all or part of the target lung. Case Report: We describe a new application of the Univent System tube(R) in three cases where intubation was presumed to be difficult, and in another with unexpected difficult intubation. The laryngeal approach was carried out with the distally displaced blocker, inserting it through the sub-epiglottis or the posterior commissure visible orifice. The tube was firmly held and slid through the length of the blocker, rotating slowly until fully introduced. The advantages and criteria for its use are discussed. Conclusion: Although the double-lumen tube is the first choice for one-lung ventilation, the Univent tube is a good option for selective bronchial intubation and in patients in whom difficult intubation is predicted.
引用
收藏
页码:765 / 767
页数:3
相关论文
共 10 条
[1]   SELECTIVE BRONCHIAL INTUBATION WITH THE UNIVENT SYSTEM IN PATIENTS WITH A TRACHEOSTOMY [J].
BELLVER, J ;
GARCIAAGUADO, R ;
DEANDRES, J ;
VALIA, JC ;
BOLINCHES, R .
ANESTHESIOLOGY, 1993, 79 (06) :1453-1454
[2]   PREDICTING DIFFICULT INTUBATION [J].
FRERK, CM .
ANAESTHESIA, 1991, 46 (12) :1005-1008
[3]  
HASSAN A, 1992, J CARDIOTHORAC VASC, V6, P208
[4]  
INOUE H, 1982, J THORAC CARDIOV SUR, V83, P940
[5]   ENDOTRACHEAL-TUBE WITH MOVABLE BLOCKER TO PREVENT ASPIRATION OF INTRATRACHEAL BLEEDING [J].
INOUE, H ;
SHOHTSU, A ;
OGAWA, J ;
KOIDE, S ;
KAWADA, S .
ANNALS OF THORACIC SURGERY, 1984, 37 (06) :497-499
[6]  
INOUE H, 1994, J THORAC CARDIOVASC, V101, P1171
[7]   SELECTIVE BRONCHIAL INTUBATION FOR ONE LUNG ANESTHESIA IN THORACIC-SURGERY - A NEW METHOD [J].
NAZARI, S ;
TRAZZI, R ;
MONCALVO, F ;
ZONTA, A ;
CAMPANI, M .
ANAESTHESIA, 1986, 41 (05) :519-526
[8]  
PARKER SD, 1993, PRINCIPLES PRACTICE, P2387
[9]   PROSPECTIVE-STUDY OF ROBERTSHAW ENDOBRONCHIAL CATHETER IN THORACIC SURGERY [J].
READ, RC ;
FRIDAY, CD ;
EASON, CN .
ANNALS OF THORACIC SURGERY, 1977, 24 (02) :156-161
[10]   TRACHEAL RUPTURE FOLLOWING THE INSERTION OF A DISPOSABLE DOUBLE-LUMEN ENDOTRACHEAL-TUBE [J].
WAGNER, DL ;
GAMMAGE, GW ;
WONG, ML .
ANESTHESIOLOGY, 1985, 63 (06) :698-700