Amperometric detection for capillary electrophoresis at a sol-gel carbon composite electrode

被引:39
作者
Hua, L [1 ]
Tan, SN [1 ]
机构
[1] Nanyang Technol Univ, Sch Sci, Div Chem, Singapore 259756, Singapore
关键词
capillary electrophoresis; amperometry; neurotransmitters; sol-gel carbon; electrode;
D O I
10.1016/S0003-2670(99)00667-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of a newly developed sol-gel carbon composite electrode (CCE) was evaluated for the amperometric detection in capillary electrophoresis (CE). A sol-gel CCE of ca. 150 mu m m diameter was employed as a detector in a wall-jet arrangement. The use of simple anodic electrochemical pre-treatment at +1.80 V versus SCE for 2 min was shown to produce an improved and reasonably stable electrode response compared to that of the untreated electrode. Although, the enhancement resulting from electrochemical pre-treatment was not permanent, the results obtained under CE conditions demonstrated that the sol-gel CCE with a single electrochemical pre-treatment was suitable for CE applications. Following the electrochemical pre-treatment, a sample mixture containing dopamine, catechol, epinephrine and norepinephrine was separated in a CE system. The calibration graphs for all these neurotransmitters were found to be linear in the range 1-400 mu M and the detection limit (signal/noise = 3) for each neurotransmitter examined was <350 amol. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 28 条
[1]  
Beale SC, 1998, ANAL CHEM, V70, p279R
[2]   ELECTROCATALYTIC OXIDATION OF NADH AND ASCORBIC-ACID ON ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODES [J].
CENAS, N ;
ROZGAITE, J ;
POCIUS, A ;
KULYS, J .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 154 (1-2) :121-128
[3]   Application of a nickel-microelectrode-incorporated end-column detector for capillary electrophoretic determination of alditols and alcohols [J].
Chen, MC ;
Huang, HJ .
ANALYTICA CHIMICA ACTA, 1997, 341 (01) :83-90
[4]   DETERMINATION OF CARBOHYDRATES BY CAPILLARY ZONE ELECTROPHORESIS WITH AMPEROMETRIC DETECTION AT A COPPER MICROELECTRODE [J].
COLON, LA ;
DADOO, R ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :476-481
[5]   CHARACTERIZATION OF ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODES [J].
ENGSTROM, RC ;
STRASSER, VA .
ANALYTICAL CHEMISTRY, 1984, 56 (02) :136-141
[6]  
EVANS JF, 1977, J ELECTROANAL CHEM, V80, P409, DOI 10.1016/0368-1874(77)80276-1
[7]   ELECTROCHEMICAL DETECTION IN MICROCOLUMN SEPARATIONS [J].
EWING, AG ;
MESAROS, JM ;
GAVIN, PF .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :A527-A537
[8]   ELECTROCHEMICAL PRETREATMENT OF CARBON-FIBERS FOR INVIVO ELECTROCHEMISTRY - EFFECTS ON SENSITIVITY AND RESPONSE-TIME [J].
FENG, JX ;
BRAZELL, M ;
RENNER, K ;
KASSER, R ;
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1863-1867
[9]   Rudimentary capillary-electrode alignment for capillary electrophoresis with electrochemical detection [J].
Fermier, AM ;
Gostkowski, ML ;
Colon, LA .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1661-1664
[10]   Simultaneous determination of sugars and organic acids by co-electroosmotic capillary electrophoresis with amperometric detection at a disk-shaped copper electrode [J].
Fu, CG ;
Song, LN ;
Fang, YZ .
ANALYTICA CHIMICA ACTA, 1998, 371 (01) :81-87