Distal femur replacement is useful in complex total knee arthroplasty revisions

被引:41
作者
Harrison, Richard J., Jr. [1 ]
Thacker, Mihir M. [1 ]
Pitcher, J. David [1 ]
Temple, H. Thomas [1 ]
Scully, Sean P. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Orthopaed Surg, Miami, FL 33101 USA
关键词
D O I
10.1097/01.blo.0000214433.64774.1b
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Revision total knee arthroplasty can be considerably more difficult in cases involving severe bone loss, complete absence of collateral ligaments, and persistent periprosthetic supracondylar femoral fractures. Modular segmental endoprosthetic distal femur replacement is a limb salvage option when other surgical options are unfeasible. The clinical performance of rotating hinge knee prostheses has greatly improved with the evolution of second and third generation designs. The increased freedom of rotation decreases the prosthetic bone stresses and the longevity. While designs have improved, the prostheses still do not match the function and longevity of condylar components with approximately a 90% survivorship at 20 years. The modular endoprosthesis rotating hinge knee prosthesis is useful for total knee arthroplasty revision in patients with inadequate bone stock, ligamentous instability, or difficult supracondylar femur fractures, especially in low demand elderly patients.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 47 条
[31]   KINEMATIC ROTATING-HINGE TOTAL KNEE ARTHROPLASTY [J].
RAND, JA ;
CHAO, EYS ;
STAUFFER, RN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (04) :489-497
[32]  
SHAW JA, 1989, ORTHOPEDICS, V12, P647
[33]  
Springer BD, 2001, CLIN ORTHOP RELAT R, P283
[34]   The modular segmental kinematic rotating hinge for nonneoplastic limb salvage [J].
Springer, BD ;
Sim, FH ;
Hanssen, AD ;
Lewallen, DG .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (421) :181-187
[35]   Aseptic loosening in cemented custom-made prosthetic replacements for bone tumours of the lower limb [J].
Unwin, PS ;
Cannon, SR ;
Grimer, RJ ;
Kemp, HBS ;
Sneath, RS ;
Walker, PS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01) :5-13
[36]   Customised hinged knee replacements as a salvage procedure for failed total knee arthroplasty [J].
Utting, MR ;
Newman, JH .
KNEE, 2004, 11 (06) :475-479
[37]   Stress shielding after total knee replacement may cause bone resorption in the distal femur [J].
vanLenthe, GH ;
Malefijt, MCD ;
Huiskes, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (01) :117-122
[38]  
WALKER PS, 1982, ORTHOP CLIN N AM, V13, P187
[39]   Comparison between a Constrained Condylar and a Rotating Hinge in revision knee surgery [J].
Walker, PS ;
Manktelow, ARJ .
KNEE, 2001, 8 (04) :269-279
[40]  
WALLDIUS B, 1960, Acta Orthop Scand, V30, P137