A Monte Carlo based radiotherapy simulator

被引:6
|
作者
Bliznakova, K [1 ]
Kolitsi, Z [1 ]
Pallikarakis, N [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras 26500, Greece
关键词
radiotherapy; dosimetry; Monte Carlo simulation;
D O I
10.1016/j.nimb.2004.02.035
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents a Monte Carlo based simulator of the radiotherapy treatment chain. The high energy simulation module (HESM) incorporates components for beam generation, irradiation set up, radiation transport modeling and dose distribution calculation. The beam is defined by means of particle charge, energy, direction and position. Comprehensive modeling of photon and electron interactions in the radiotherapy energy range has been pursued. A three-dimensional dose matrix is used to calculate the energy deposited by electrons and photons. The simulator was evaluated in terms of its accuracy of computation of 3D photon and electron beam dose distributions, by means of comparison to reported Monte Carlo studies and also to experimental data, using homogeneous and heterogeneous phantoms. The dose distribution studies demonstrated good agreement with experimental and reference data. Furthermore, the HESM has been augmented by means of an already available user-friendly GUI and a suit of modeling tools, to become a complete Monte Carlo radiotherapy simulator (MCRTS), for use in experimentation in general and specific radiotherapy applications. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:445 / 461
页数:17
相关论文
共 50 条
  • [31] Monte Carlo simulation and measurement of radiation leakage from applicators used in external electron radiotherapy
    Shimozato, Tomohiro
    Okudaira, Kuniyasu
    Fuse, Hiraku
    Tabushi, Katsuyoshi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (04): : 388 - 396
  • [32] Dosimetric evaluation of an intraoperative radiotherapy system: a measurement-based and Monte-Carlo modelling investigation
    Marsha Chin
    Pejman Rowshanfarzad
    Gabor Neveri
    Martin A. Ebert
    David Pfefferlé
    Physical and Engineering Sciences in Medicine, 2023, 46 : 687 - 701
  • [33] Dosimetric evaluation of an intraoperative radiotherapy system: a measurement-based and Monte-Carlo modelling investigation
    Chin, Marsha
    Rowshanfarzad, Pejman
    Neveri, Gabor
    Ebert, Martin A. A.
    Pfefferle, David
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (02) : 687 - 701
  • [34] Correction method for ionization chamber dosimetry in flattening filter free radiotherapy based on Monte Carlo simulation
    Zhang, Guolong
    Huang, Ji
    Wu, Guoxin
    Jin, Sunjun
    Wang, Kun
    Wu, Hao
    Zhang, Hui
    Yue, Haizheng
    Yang, Ruijie
    Wang, Yujie
    Wang, Zhipeng
    Qi, Yaping
    MEDICAL PHYSICS, 2025, 52 (03) : 1833 - 1844
  • [35] Dosimetry for synchrotron stereotactic radiotherapy:: Fricke gel and Monte Carlo calculations
    Boudou, C
    Biston, MC
    Corde, S
    Adam, JF
    Joubert, A
    Charvet, AM
    Nemoz, C
    Ferrero, C
    Estève, F
    Elleaume, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) : 65 - 68
  • [36] Monte Carlo Estimation of Cerenkov Dose for Photo-Dynamic Radiotherapy
    Chibani, O.
    Eldib, A.
    Price, R.
    Mora, G.
    Ma, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 278 - +
  • [37] Deep learning-based fast denoising of Monte Carlo dose calculation in carbon ion radiotherapy
    Zhang, Xinyang
    Zhang, Hui
    Wang, Jian
    Ma, Yuanyuan
    Liu, Xinguo
    Dai, Zhongying
    He, Rui
    He, Pengbo
    Li, Qiang
    MEDICAL PHYSICS, 2023, 50 (12) : 7314 - 7323
  • [38] Pre-treatment radiotherapy dose verification using Monte Carlo doselet modulation in a spherical phantom
    Townson, Reid W.
    Zavgorodni, Sergei
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (08) : 1923 - 1934
  • [39] Comprehensive Monte Carlo study of patient doses from cone-beam CT imaging in radiotherapy
    Marchant, T. E.
    Joshi, K. D.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (01) : 13 - 30
  • [40] Fast Monte Carlo-simulator with full collimator and detector response modelling for SPECT
    Antti O. Sohlberg
    Markus T. Kajaste
    Annals of Nuclear Medicine, 2012, 26 : 92 - 98