We have investigated the basic characteristics (scan depth, linearity, and stability) of a piezoelectric axial scanner (PAS) composed of optical fibers wound around a cylindrical piezoelectric transducer. The scan depth due to the stretching of the fibers is decreased to 77.5% by the photoelastic effect. With the application of a high voltage, pseudo-triangular signal to two PASs, a scan depth of 2 mm and scan rate of 2,000 lines/s were achieved and used to acquire a cross-sectional image of an in vivo human finger with a measurement time of 0.5s.
引用
收藏
页码:7975 / 7977
页数:3
相关论文
共 14 条
[1]   Optical frequency-domain reflectometry with a rapid wavelength-scanning superstructure-grating distributed Bragg reflector laser [J].
Amano, T ;
Hiro-Oka, H ;
Choi, D ;
Furukawa, H ;
Kano, F ;
Takeda, M ;
Nakanishi, M ;
Shimizu, K ;
Ohbayashi, K .
APPLIED OPTICS, 2005, 44 (05) :808-816
[2]   Subsurface defect detection in ceramics by high-speed high-resolution optical coherent tomography [J].
Bashkansky, M ;
Duncan, MD ;
Kahn, M ;
Lewis, D ;
Reintjes, J .
OPTICS LETTERS, 1997, 22 (01) :61-63
[3]   All-fiber variable optical delay line for applications in optical coherence tomography: feasibility study for a novel delay line [J].
Choi, E ;
Na, JH ;
Ryu, Y ;
Mudhana, G ;
Lee, BH .
OPTICS EXPRESS, 2005, 13 (04) :1334-1345
[4]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[5]  
HIRATA K, 2002, AS S BIOM OPT PHOT B, P148
[6]   High-speed path-length scanning with a multiple-pass cavity delay line [J].
Hsiung, PL ;
Li, XD ;
Chudoba, C ;
Hartl, I ;
Ko, TH ;
Fujimoto, JG .
APPLIED OPTICS, 2003, 42 (04) :640-648
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[9]   Dynamic observation of sweat glands of human finger tip using all-optical-fiber high-speed optical coherence tomography [J].
Ohmi, M ;
Nohara, K ;
Ueda, Y ;
Fuji, T ;
Haruna, M .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2005, 44 (24-27) :L854-L856
[10]   Fast-Fourier-domain delay line for in vivo optical coherence tomography with a polygonal scanner [J].
Oldenburg, AL ;
Reynolds, JJ ;
Marks, DL ;
Boppart, SA .
APPLIED OPTICS, 2003, 42 (22) :4606-4611