Modeling Of Z-Source Network For Neutral Point Clamped Multilevel Inverter

被引:0
|
作者
Kuppuswamy, C. L. [1 ]
Raghavendiran, T. A. [2 ]
机构
[1] Sathyabama Univ, Madras, Tamil Nadu, India
[2] Anand Inst Higher Technol, Madras, Tamil Nadu, India
关键词
Modeling of Z-Source; NPC inverter; Active mode; Shoot through mode; Non-shoot through mode;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Renewable energy sources such as wind, solar and fuel cell have a wide voltage change range due to the nature of the sources. Fuel cell stack voltage drops greatly with current and wind generator voltage varies with wind speed and control. Photovoltaic cell's voltage varies with temperature and irradiation. The traditional voltage source inverter that has been the power conversion technology for these energy sources cannot cope with this wide voltage change nature and often requires additional voltage boost by additional DC-DC converter. The Z-source inverters can solve this problem. Multilevel Inverter (MU) has been recognized as an attractive topology for high voltage DC-AC conversion. This paper presents design of Impedance (Z) Source network for Neutral Point Clamped (NPC) three level inverter. This inverter uses single impedance source network and less clamping diodes. The operating modes of Z-Source Inverter (ZSI) are Shoot through mode, Active and Open mode. The detailed design aspects in these modes are presented.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 50 条
  • [41] A novel Z-source inverter
    Lin, Hongjian (lhj41333696@163.com), 1600, Science Press (38):
  • [42] Improved Z-source inverter
    College of Automatic Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, Jiangsu Province, China
    Zhongguo Dianji Gongcheng Xuebao, 2009, 30 (28-34):
  • [43] Novel Space-Vector Pulse-Width-Modulation Mechanism for Three-Level Neutral-Point-Clamped Z-Source Inverter
    Zhang, Ji
    Wai, Rong-Jong
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 5 - 9
  • [44] Modeling and control strategy of three phase neutral point clamped multilevel PV inverter connected to the grid
    Arulkumar, K.
    Vijayakumar, D.
    Palanisamy, K.
    JOURNAL OF BUILDING ENGINEERING, 2015, 3 : 195 - 202
  • [45] Improved Trans-Z-Source Active-Neutral-Point-Clamped Multilevel Inverter With Continuous Input Current for Induction Motor Drives
    Johny, Lallu Mol K.
    Mathew, Jaison
    Gopakumar, K.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2025, 72 (02) : 1281 - 1291
  • [46] Analytical EMI Modeling of an Active Neutral Point Clamped Inverter
    Kharanaq, Fatemeh Abolqasemi
    Emadi, Ali
    Bilgin, Berker
    IECON 2021 - 47TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2021,
  • [47] Small Signal Modeling, Analysis and Control of Γ-Z-Source Inverter
    Poursmaeil, M.
    Dizgah, Sh Moradinejad
    Torkaman, H.
    Afjei, E.
    2017 25TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2017, : 1216 - 1222
  • [48] Modeling and controller design of the Z-source inverter with inductive load
    Shen, Miaosen
    Tang, Qingsong
    Peng, Fang Z.
    2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 1804 - 1809
  • [49] A New Hybrid Active Neutral Point Clamped Flying Capacitor Multilevel Inverter
    Naderi, Roozbeh
    Smedley, Keyue
    2015 THIRTIETH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2015), 2015, : 794 - 798
  • [50] Three-phase cascaded neutral-point-clamped multilevel inverter
    Qanbari, Tohid
    Nazarpour, Daryoush
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (08)