Amperometric Biosensors Based on Biotinylated Single-Walled Carbon Nanotubes

被引:26
作者
Holzinger, M. [1 ]
Haddad, R. [1 ,2 ]
Maaref, A. [2 ]
Cosnier, S. [1 ]
机构
[1] Univ Grenoble 1, CNRS, UMR 5250, ICMG,FR 2607,Dept Chim Mol, F-38041 Grenoble 9, France
[2] Fac Sci Monastir, Lab Phys & Chim Interfaces, Monastir 5019, Tunisia
关键词
Carbon Nanotube; Biosensor; Polypyrrole; Pyrene; Amperometry; COMPLEX; AVIDIN;
D O I
10.1166/jnn.2009.1549
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
One challenging goal for the development of biosensors; is the conception of three dimensional biostructures on electrode surfaces. In this context, single-walled carbon nanotube coatings (SWCNTs), functionalized by biotin groups, were investigated to develop 3D conductive nanostructures allowing a post-functionalization by biological macromolecules. This specific anchoring of biomolecules was carried via the affinity interactions using the avidin-biotin system. For this purpose, a biotinylated pyrene was specially synthesized to develop a non-covalent functionalization based on pi-interactions between pyrene and the nanotube sidewall. SWCNT coatings were also biotinylated via electropolymerization of biotin-pyrrole derivatives at 0.95 V in CH3CN electrolyte. The resulting biotinylated SWCNTs were modified by an avidin protein via affinity interactions and characterized with scanning electron microscopy. The biofunctionalization by a biotinylated glucose oxidase (GOX) was performed by successive incubation in avidin and GOX aqueous solutions via avidin bridges. The efficiency of the enzyme anchoring was examined through the electro-enzymatic activity of the modified electrodes towards the detection of glucose at 0.7 V versus SCE. The glucose sensitivity and maximum current density were 1.6 mAM(-1) cm(-2) and 131 mu Acm(-2) respectively for pyrene biotin-SWCNT electrode and 2.5 mAM(-1) cm(-2) and 178 mu Acm(-2) respectively for the poly(pyrrole biotin)-SWCNT
引用
收藏
页码:6042 / 6046
页数:5
相关论文
共 16 条
[1]   Poly(pyrrole-biotin): a new polymer for biomolecule grafting on electrode surfaces [J].
Cosnier, S ;
Lepellec, A .
ELECTROCHIMICA ACTA, 1999, 44 (11) :1833-1836
[2]  
Cosnier S, 1998, ELECTROANAL, V10, P808, DOI 10.1002/(SICI)1521-4109(199809)10:12<808::AID-ELAN808>3.3.CO
[3]  
2-B
[4]   A biotinylated conducting polypyrrole for the spatially controlled construction of an amperometric biosensor [J].
Cosnier, S ;
Stoytcheva, M ;
Senillou, A ;
Perrot, H ;
Furriel, RPM ;
Leone, FA .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3692-3697
[5]   THE PRODUCTION AND STRUCTURE OF PYROLYTIC CARBON NANOTUBES (PCNTS) [J].
ENDO, M ;
TAKEUCHI, K ;
IGARASHI, S ;
KOBORI, K ;
SHIRAISHI, M ;
KROTO, HW .
JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 1993, 54 (12) :1841-1848
[6]  
Green N M, 1975, Adv Protein Chem, V29, P85, DOI 10.1016/S0065-3233(08)60411-8
[7]   Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: Routes to impedimetric immunosensors, DNA-Sensors, and enzyme biosensors [J].
Katz, E ;
Willner, I .
ELECTROANALYSIS, 2003, 15 (11) :913-947
[8]   ARE FULLERENE TUBULES METALLIC [J].
MINTMIRE, JW ;
DUNLAP, BI ;
WHITE, CT .
PHYSICAL REVIEW LETTERS, 1992, 68 (05) :631-634
[9]   Atomic structure and electronic properties of single-walled carbon nanotubes [J].
Odom, TW ;
Huang, JL ;
Kim, P ;
Lieber, CM .
NATURE, 1998, 391 (6662) :62-64
[10]   ENZYME-MODIFIED CARBON-FIBER MICROELECTRODES WITH MILLISECOND RESPONSE-TIMES [J].
PANTANO, P ;
MORTON, TH ;
KUHR, WG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (05) :1832-1833