Comparison of Biophysical Factors Influencing on Emphysema Quantification with Low-dose CT

被引:0
作者
Heo, Chang Yong [1 ]
Kim, Jong Hyo [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Interdisciplinary Program Radiat Appl Life Sci, Seoul, South Korea
来源
MEDICAL IMAGING 2014: COMPUTER-AIDED DIAGNOSIS | 2014年 / 9035卷
关键词
Emphysema; Quantification; Biophysical factor; Low-dose CT; Lung; CAD; PULMONARY-EMPHYSEMA; COMPUTED-TOMOGRAPHY; LUNG DENSITOMETRY; BODY CT; MORPHOMETRY; PROGRESSION; SMOKERS; COPD;
D O I
10.1117/12.2043894
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Emphysema Index(EI) measurements in MDCT is known to be influenced by various biophysical factors such as total lung volume, and body size. We investigated the association of the four biophysical factors with emphysema index in low-dose MDCT. In particular, we attempted to identify a potentially stronger biophysical factor than total lung volume. A total of 400 low-dose MDCT volumes taken at 120kVp, 40mAs, 1mm thickness, and B30f reconstruction kernel were used. The lungs, airways, and pulmonary vessels were automatically segmented, and two Emphysema Indices, relative area below -950HU(RA950) and 15th percentile(Perc15), were extracted from the segmented lungs. The biophysical factors such as total lung volume(TLV), mode of lung attenuation(ModLA), effective body diameter(EBD), and the water equivalent body diameter(WBD) were estimated from the segmented lung and body area. The association of biophysical factors with emphysema indices were evaluated by correlation coefficients. The mean emphysema indices were 8.3 +/- 5.5(%) in RA950, and -930 +/- 18(HU) in Perc15. The estimates of biophysical factors were 4.7 +/- 1.0(L) in TLV, -901 +/- 21(HU) in ModLA, 26.9 +/- 2.2(cm) in EBD, and 25.9 +/- 2.6(cm) in WBD. The correlation coefficients of biophysical factors with RA950 were 0.73 in TLV, 0.94 in ModLA, 0.31 in EBD, and 0.18 WBD, the ones with Perc15 were 0.74 in TLV, 0.98 in ModLA, 0.29 in EBD, and 0.15 WBD. Study results revealed that two biophysical factors, TLV and ModLA, mostly affects the emphysema indices. In particular, the ModLA exhibited strongest correlation of 0.98 with Perc15, which indicating the ModLA is the most significant confounding biophysical factor in emphysema indices measurement.
引用
收藏
页数:7
相关论文
共 50 条
[41]   Low-dose CT measurements of airway dimensions and emphysema associated with airflow limitation in heavy smokers: a cross sectional study [J].
Dijkstra, Akkelies E. ;
Postma, Dirkje S. ;
ten Hacken, Nick ;
Vonk, Judith M. ;
Oudkerk, Matthijs ;
van Ooijen, Peter M. A. ;
Zanen, Pieter ;
Hoesein, Firdaus A. Mohamed ;
van Ginneken, Bram ;
Schmidt, Michael ;
Groen, Harry J. M. .
RESPIRATORY RESEARCH, 2013, 14
[42]   Association between visual emphysema and lung nodules on low-dose CT scan in a Chinese Lung Cancer Screening Program (Nelcin-B3) [J].
Yang, Xiaofei ;
Dorrius, Monique D. ;
Jiang, Wenzhen ;
Nie, Zhenhui ;
Vliegenthart, Rozemarijn ;
Groen, Harry J. M. ;
Heuvelmans, Marjolein A. ;
Sidorenkov, Grigory ;
Vonder, Marleen ;
Ye, Zhaoxiang ;
de Bock, Geertruida H. .
EUROPEAN RADIOLOGY, 2022, 32 (12) :8162-8170
[43]   Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules [J].
Karabulut, N ;
Törü, M ;
Gelebek, V ;
Gülsün, M ;
Ariyurek, OM .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2764-2769
[44]   Dose-aware denoising diffusion model for low-dose CT [J].
Kim, Seongjun ;
Kim, Byeongjoon ;
Baek, Jongduk .
PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (14)
[45]   Characterization of a Mouse Model of Emphysema Induced by Multiple Instillations of Low-Dose Elastase [J].
Oliveira, Milena V. ;
Abreu, Soraia C. ;
Padilha, Gisele A. ;
Rocha, Nazareth N. ;
Maia, Ligia A. ;
Takiya, Christina M. ;
Xisto, Debora G. ;
Suki, Bela ;
Silva, Pedro L. ;
Rocco, Patricia R. M. .
FRONTIERS IN PHYSIOLOGY, 2016, 7
[46]   Low-dose CT scan screening for lung cancer: comparison of images and radiation doses between low-dose CT and follow-up standard diagnostic CT [J].
Ono, Koji ;
Hiraoka, Toru ;
Ono, Asami ;
Komatsu, Eiji ;
Shigenaga, Takehiko ;
Takaki, Hajime ;
Maeda, Toru ;
Ogusu, Hiroyuki ;
Yoshida, Shintaro ;
Fukushima, Kiyoyasu ;
Kai, Michiaki .
SPRINGERPLUS, 2013, 2 :1-8
[47]   Not Every Low-Dose Is Low-Dose: Impact of Revising Low-Dose CT Protocol on Mean Effective Radiation Exposure [J].
Deyirmendjian, Claudia ;
Lee, Seohyuk ;
Noureldin, Yasser A. ;
Hegyi, Gyorgy ;
Stein, Lawrence ;
Artho, Giovanni ;
Andonian, Sero .
JOURNAL OF ENDOUROLOGY, 2022, 36 (06) :835-840
[48]   Bronchiectasis in Low-Dose CT Screening for Lung Cancer [J].
Cai, Qiang ;
Triphuridet, Natthaya ;
Zhu, Yeqing ;
You, Nan ;
Yip, Rowena ;
Yankelevitz, David F. ;
Henschke, Claudia, I .
RADIOLOGY, 2022, 304 (02) :437-447
[49]   LOW-DOSE CT DENOISING WITH CONVOLUTIONAL NEUELA NETWORK [J].
Chen, Hu ;
Zhang, Yi ;
Zhang, Weihua ;
Liao, Peixi ;
Li, Ke ;
Zhou, Jiliu ;
Wang, Ge .
2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, :143-146
[50]   Amyloid PET quantification using low-dose CT-guided anatomic standardization [J].
Hiroshi Matsuda ;
Tensho Yamao ;
Mitsuru Shakado ;
Yoko Shigemoto ;
Kyoji Okita ;
Noriko Sato .
EJNMMI Research, 11