Comparison of Biophysical Factors Influencing on Emphysema Quantification with Low-dose CT

被引:0
作者
Heo, Chang Yong [1 ]
Kim, Jong Hyo [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Interdisciplinary Program Radiat Appl Life Sci, Seoul, South Korea
来源
MEDICAL IMAGING 2014: COMPUTER-AIDED DIAGNOSIS | 2014年 / 9035卷
关键词
Emphysema; Quantification; Biophysical factor; Low-dose CT; Lung; CAD; PULMONARY-EMPHYSEMA; COMPUTED-TOMOGRAPHY; LUNG DENSITOMETRY; BODY CT; MORPHOMETRY; PROGRESSION; SMOKERS; COPD;
D O I
10.1117/12.2043894
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Emphysema Index(EI) measurements in MDCT is known to be influenced by various biophysical factors such as total lung volume, and body size. We investigated the association of the four biophysical factors with emphysema index in low-dose MDCT. In particular, we attempted to identify a potentially stronger biophysical factor than total lung volume. A total of 400 low-dose MDCT volumes taken at 120kVp, 40mAs, 1mm thickness, and B30f reconstruction kernel were used. The lungs, airways, and pulmonary vessels were automatically segmented, and two Emphysema Indices, relative area below -950HU(RA950) and 15th percentile(Perc15), were extracted from the segmented lungs. The biophysical factors such as total lung volume(TLV), mode of lung attenuation(ModLA), effective body diameter(EBD), and the water equivalent body diameter(WBD) were estimated from the segmented lung and body area. The association of biophysical factors with emphysema indices were evaluated by correlation coefficients. The mean emphysema indices were 8.3 +/- 5.5(%) in RA950, and -930 +/- 18(HU) in Perc15. The estimates of biophysical factors were 4.7 +/- 1.0(L) in TLV, -901 +/- 21(HU) in ModLA, 26.9 +/- 2.2(cm) in EBD, and 25.9 +/- 2.6(cm) in WBD. The correlation coefficients of biophysical factors with RA950 were 0.73 in TLV, 0.94 in ModLA, 0.31 in EBD, and 0.18 WBD, the ones with Perc15 were 0.74 in TLV, 0.98 in ModLA, 0.29 in EBD, and 0.15 WBD. Study results revealed that two biophysical factors, TLV and ModLA, mostly affects the emphysema indices. In particular, the ModLA exhibited strongest correlation of 0.98 with Perc15, which indicating the ModLA is the most significant confounding biophysical factor in emphysema indices measurement.
引用
收藏
页数:7
相关论文
共 50 条
[21]   Multivariate Compensation of Quantitative Pulmonary Emphysema Metric Variation From Low-Dose, Whole-Lung CT Scans [J].
Keller, Brad M. ;
Reeves, Anthony P. ;
Henschke, Claudia I. ;
Yankelevitz, David F. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :W495-W502
[22]   Ultra-low-dose CT combined with noise reduction techniques for quantification of emphysema in COPD patients: An intra-individual comparison study with standard-dose CT [J].
Wisselink, H. J. ;
Pelgrim, G. J. ;
Rook, M. ;
Imkamp, K. ;
van Ooijen, P. M. A. ;
van den Berge, M. ;
de Bock, G. H. ;
Vliegenthart, R. .
EUROPEAN JOURNAL OF RADIOLOGY, 2021, 138
[23]   Emphysema progression is visually detectable in low-dose CT in continuous but not in former smokers [J].
Wille, Mathilde Marie Winkler ;
Thomsen, Laura H. ;
Dirksen, Asger ;
Petersen, Jens ;
Pedersen, Jesper Holst ;
Shaker, Saher B. .
EUROPEAN RADIOLOGY, 2014, 24 (11) :2692-2699
[24]   Emphysema progression is visually detectable in low-dose CT in continuous but not in former smokers [J].
Mathilde Marie Winkler Wille ;
Laura H. Thomsen ;
Asger Dirksen ;
Jens Petersen ;
Jesper Holst Pedersen ;
Saher B. Shaker .
European Radiology, 2014, 24 :2692-2699
[25]   Emphysema quantification and lung volumetry in chest X-rayequivalent ultralow dose CT - Intra-individual comparison with standard dose CT [J].
Messerli, Michael ;
Ottilinger, Thorsten ;
Warschkow, Rene ;
Leschka, Sebastian ;
Alkadhi, Hatem ;
Wildermuth, Simon ;
Bauer, Ralf W. .
EUROPEAN JOURNAL OF RADIOLOGY, 2017, 91 :1-9
[26]   Emphysema Quantification Using Ultralow-Dose CT With Iterative Reconstruction and Filtered Back Projection [J].
Nishio, Mizuho ;
Koyama, Hisanobu ;
Ohno, Yoshiharu ;
Negi, Noriyuki ;
Seki, Shinichiro ;
Yoshikawa, Takeshi ;
Sugimura, Kazuro .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (06) :1184-1192
[27]   Emphysema Quantification from CT Scans Using Novel Application of Diaphragm Curvature Estimation: Comparison with Standard Quantification Methods and Pulmonary Function Data [J].
Keller, Brad M. ;
Reeves, Anthony P. ;
Yankelevitz, David F. ;
Henschke, Claudia, I ;
Graham Barr, R. .
MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS, 2009, 7260
[28]   Normalized emphysema scores on low dose CT: Validation as an imaging biomarker for mortality [J].
Gallardo-Estrella, Leticia ;
Pompe, Esther ;
de Jong, Pim A. ;
Jacobs, Colin ;
van Rikxoort, Eva M. ;
Prokop, Mathias ;
Sanchez, Clara I. ;
van Ginneken, Bram .
PLOS ONE, 2017, 12 (12)
[29]   A Challenge for Emphysema Quantification Using a Deep Learning Algorithm With Low-dose Chest Computed Tomography [J].
Choi, Hyewon ;
Kim, Hyungjin ;
Jin, Kwang Nam ;
Jeong, Yeon Joo ;
Chae, Kum Ju ;
Lee, Kyung Hee ;
Yong, Hwan Seok ;
Gil, Bomi ;
Lee, Hye-Jeong ;
Lee, Ki Yeol ;
Jeon, Kyung Nyeo ;
Yi, Jaeyoun ;
Seo, Sola ;
Ahn, Chulkyun ;
Lee, Joonhyung ;
Oh, Kyuhyup ;
Goo, Jin Mo .
JOURNAL OF THORACIC IMAGING, 2022, 37 (04) :253-261
[30]   Low-dose CT of postoperative pelvic fractures: a comparison with radiography [J].
Eriksson, Thomas ;
Berg, Per ;
Olerud, Claes ;
Shalabi, Adel ;
Hanni, Mari .
ACTA RADIOLOGICA, 2019, 60 (01) :85-91