Quantitative determination of clopidogrel active metabolite in human plasma by LC-MS/MS

被引:108
|
作者
Takahashi, Makoto [1 ]
Pang, Henrianna [2 ]
Kawabata, Kiyoshi [3 ]
Farid, Nagy A. [4 ]
Kurihara, Atsushi [1 ]
机构
[1] Daiichi Sankyo Co Ltd, Drug Metab & Pharmacokinet Res Labs, Shinagawa Ku, Tokyo 1408710, Japan
[2] NoAb BioDiscoveries Inc, Mississauga, ON L5N 8G4, Canada
[3] Daiichi Sonkyo RD ASSOCIE Co Ltd, Res Dept 2, Shinagawa Ku, Tokyo 1400001, Japan
[4] Eli Lilly & Co, Lilly Corp Ctr, Lilly Res Labs, Indianapolis, IN 46285 USA
关键词
Clopidogrel; Active metabolite; Thiol compound; 2-Bromo-3 '-methoxyacetophenone; LC-MS/MS; Pharmacokinetics;
D O I
10.1016/j.jpba.2008.08.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A quantitative method for the determination of clopidogrel active metabolite (AM) in human plasma was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). clopidogrel AM contains a thiol group, thus requiring stabilization in biological samples. The alkylating reagent 2-bromo-3'-methoxyacetophenone was used to stabilize clopidogrel AM in blood. Ail analog of the derivatized clopidogrel AM Was Used as the internal standard (IS). The derivatized samples were subjected to solid-phase extraction with a C2 disk plate and the overall procedure exhibited good reaction (more than 90%) and recovery efficiencies (from 85% to 105%). The derivative of clopidogrel AM (MP-AM) and IS were separated on an ODS column and quantified by tandem mass spectrometry with electrospray ionization. No significant endogenous peaks corresponding to MP-AM or IS were detected ill blank human plasma samples, and no significant matrix effect was observed for MP-AM and IS in human plasma samples (from 102% to 121%). The calibration curve ranged from 0.5 to 250 ng/mL with good linearity, and extended by validation of a 50-fold dilution. In the intra- and inter-assay reproducibility tests, the accuracy and precision were within 12% relative error and 6% coefficient of variation, respectively. The derivatized MPAM was stable in human plasma for 4 months at -80 C. The validated method Was Successfully used to analyze clinical samples and determine the pharmacokinetics of clopidogrel AM. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1219 / 1224
页数:6
相关论文
共 50 条
  • [1] Determination of Clopidogrel Active Metabolite in Beagle Dog Plasma by LC-MS/MS
    Zhao X.
    Sun H.
    Zhang Q.
    Ren T.-M.
    Gu J.-K.
    Gu, Jing-Kai (gujk@jlu.edu.cn), 1600, Chinese Society for Mass Spectrometry (38): : 460 - 467
  • [2] Simultaneous determination of clopidogrel, 2-oxo-clopidogrel, and the thiol metabolite of clopidogrel in human plasma by LC-MS/MS
    Xu, Lei
    Li, Ran
    Li, Juan
    Dong, Zhou
    Zong, Jiaxin
    Tan, Chuchu
    Ye, Zekang
    Shi, Lu
    Gong, Xiaoxuan
    Li, Chunjian
    JOURNAL OF BIOMEDICAL RESEARCH, 2022, 36 (02): : 109 - 119
  • [3] Simultaneous determination of clopidogrel, 2-oxo-clopidogrel,and the thiol metabolite of clopidogrel in human plasma by LC-MS/MS
    Lei Xu
    Ran Li
    Juan Li
    Zhou Dong
    Jiaxin Zong
    Chuchu Tan
    Zekang Ye
    Lu Shi
    Xiaoxuan Gong
    Chunjian Li
    TheJournalofBiomedicalResearch, 2022, 36 (02) : 109 - 119
  • [4] Determination of clopidogrel metabolite (SR26334) in human plasma by LC-MS
    Ksycinska, H
    Rudzki, P
    Bukowska-Kiliszek, M
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (02) : 533 - 539
  • [5] Determination of Clopidogrel in Human Plasma by a Validated LC-MS/MS Method
    Svinarov, Dobrin A.
    Kasabova, Lilia V.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 : A021 - A021
  • [6] A New and Sensitive LC-MS/MS Method for the Determination of Clopidogrel in Human Plasma
    Bibire, Nela
    Vieriu, Madalina
    Tantaru, Gladiola
    Apostu, Mihai
    Agoroaei, Luminita
    Panainte, Alina Diana
    Znagovan, Alexandru
    Vlase, Aurel
    REVISTA DE CHIMIE, 2014, 65 (07): : 807 - 810
  • [7] Simultaneous determination and determination of sildenafil and its active metabolite in human plasma using LC-MS/MS method
    Li, Lin-ling
    Zhang, Xiu-jin
    Zheng, Chao
    Fan, Ming-xia
    Xu, Hao-yun
    Yi, Jin-ling
    Feng, Yan
    Luo, Xi
    Li, Wei-hua
    Cheng, Ze-neng
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (10)
  • [8] Quantitative determination of octylonium in human plasma by LC-MS
    Kim, Kibum
    Jung, Haehum
    Yun, Hyi-Yoel
    Moon, Seung-Ok
    Yoon, Young-Ran
    Kwon, Kwang-il
    Kim, Hyesoo
    Shon, Soojung
    Kang, Wonku
    CHROMATOGRAPHIA, 2007, 66 (3-4) : 257 - 260
  • [9] Simultaneous determination of subutinib and its active metabolite in human plasma by LC-MS/MS: Application to pharmacokinetic study
    Ding Li-kun
    Yang Lin
    Chen Su-ning
    Li Jian-kang
    Wen Ai-dong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1001 : 22 - 26
  • [10] Simultaneous Determination of Orelabrutinib, Zanubrutinib, Ibrutinib and Its Active Metabolite in Human Plasma Using LC-MS/MS
    Sun, Lu-Ning
    Zhao, Yang
    Qian, Zhou-Yi
    Chen, Xiang-Long
    Ma, Hong
    Guo, Yu-Jiao
    Shen, Hao
    Wang, Yong-Qing
    MOLECULES, 2023, 28 (03):