Development of an Electrochemical Paper-Based Analytical Device for Trace Detection of Virus Particles

被引:70
作者
Channon, Robert B. [1 ]
Yang, Yuanyuan [1 ]
Feibelman, Kristen M. [2 ]
Geiss, Brian J. [2 ,4 ]
Dandy, David S. [3 ,4 ]
Henry, Charles S. [1 ,3 ,4 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
[2] Colorado State Univ, Dept Microbiol Immunol & Pathol, Ft Collins, CO 80523 USA
[3] Colorado State Univ, Dept Chem & Biol Engn, Ft Collins, CO 80523 USA
[4] Colorado State Univ, Sch Biomed Engn, Ft Collins, CO 80523 USA
关键词
WEST-NILE-VIRUS; LATERAL-FLOW ASSAY; APTAMER-BASED SENSORS; LABEL-FREE DETECTION; IMPEDANCE SPECTROSCOPY; ZIKA VIRUS; IMPEDIMETRIC IMMUNOSENSORS; JAPANESE ENCEPHALITIS; INFLUENZA-VIRUS; RAPID DETECTION;
D O I
10.1021/acs.analchem.8b02042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Viral pathogens are a serious health threat around the world, particularly in resource limited settings, where current sensing approaches are often insufficient and slow, compounding the spread and burden of these pathogens. Here, we describe a label-free, point-of-care approach toward detection of virus particles, based on a microfluidic paper-based analytical device with integrated microwire Au electrodes. The device is initially characterized through capturing of streptavidin modified nanoparticles by biotin-modified microwires. An order of magnitude improvement in detection limits is achieved through use of a microfluidic device over a classical static paper-based device, due to enhanced mass transport and capturing of particles on the modified electrodes. Electrochemical impedance spectroscopy detection of West Nile virus particles was carried out using antibody functionalized Au microwires, achieving a detection limit of 10.2 particles in 50 mu L of cell culture media. No increase in signal is found on addition of an excess of a nonspecific target (Sindbis). This detection motif is significantly cheaper (similar to$1 per test) and faster (similar to 30 min) than current methods, while achieving the desired selectivity and sensitivity. This sensing motif represents a general platform for trace detection of a wide range of biological pathogens.
引用
收藏
页码:7777 / 7783
页数:7
相关论文
共 55 条
[1]   Sindbis virus-induced silencing of dengue viruses in mosquitoes [J].
Adelman, ZN ;
Blair, CD ;
Carlson, JO ;
Beaty, BJ ;
Olson, KE .
INSECT MOLECULAR BIOLOGY, 2001, 10 (03) :265-273
[2]   Development of a Quasi-Steady Flow Electrochemical Paper-Based Analytical Device [J].
Adkins, Jaclyn A. ;
Noviana, Eka ;
Henry, Charles S. .
ANALYTICAL CHEMISTRY, 2016, 88 (21) :10639-10647
[3]   Electrochemical detection in paper-based analytical devices using microwire electrodes [J].
Adkins, Jaclyn A. ;
Henry, Charles S. .
ANALYTICA CHIMICA ACTA, 2015, 891 :247-254
[4]   Excretion of West Nile Virus in Urine During Acute Infection [J].
Barzon, Luisa ;
Pacenti, Monia ;
Franchin, Elisa ;
Pagni, Silvana ;
Martello, Thomas ;
Cattai, Margherita ;
Cusinato, Riccardo ;
Palu, Giorgio .
JOURNAL OF INFECTIOUS DISEASES, 2013, 208 (07) :1086-1092
[5]   Challenges of Electrochemical Impedance Spectroscopy in Protein Biosensing [J].
Bogomolova, A. ;
Komarova, E. ;
Reber, K. ;
Gerasimov, T. ;
Yavuz, O. ;
Bhatt, S. ;
Aldissi, M. .
ANALYTICAL CHEMISTRY, 2009, 81 (10) :3944-3949
[6]   EVALUATION OF A RAPID ANALYTE MEASUREMENT PLATFORM AND REAL-TIME REVERSE-TRANSCRIPTASE POLYMERASE CHAIN REACTION ASSAY WEST NILE VIRUS DETECTION SYSTEM IN MOSQUITO POOLS [J].
Burkhalter, Kristen L. ;
Horiuchi, Kalanthe ;
Biggerstaff, Brad J. ;
Savage, Harry M. ;
Nasci, Roger S. .
JOURNAL OF THE AMERICAN MOSQUITO CONTROL ASSOCIATION, 2014, 30 (01) :21-30
[7]   Electrochemical Impedance Spectroscopy [J].
Chang, Byoung-Yong ;
Park, Su-Moon .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 3, 2010, 3 :207-229
[8]   Rapid flow in multilayer microfluidic paper-based analytical devices [J].
Channon, Robert B. ;
Nguyen, Michael P. ;
Scorzelli, Alexis G. ;
Henry, Elijah M. ;
Volckens, John ;
Dandy, David S. ;
Henry, Charles S. .
LAB ON A CHIP, 2018, 18 (05) :793-802
[9]   Label-free impedance biosensors: Opportunities and challenges [J].
Daniels, Jonathan S. ;
Pourmand, Nader .
ELECTROANALYSIS, 2007, 19 (12) :1239-1257
[10]   Cost-Effective and Handmade Paper-Based Immunosensing Device for Electrochemical Detection of Influenza Virus [J].
Devarakonda, Sivaranjani ;
Singh, Renu ;
Bhardwaj, Jyoti ;
Jang, Jaesung .
SENSORS, 2017, 17 (11)