Roentgen stereophotogrammetric analysis (RSA) was used to investigate the stability of the tibial component in unicompartmental knee arthroplasty. Twenty patients were implanted with a Howmedica Duracon UNI prosthesis (Limerick, Ireland) and studied for an average follow-LIP of 30 months. In most cases, the displacements detected at 1-year follow-up were small (ie, not exceeding 0.5 mm for translations and not exceeding 1.0 for rotations). Only 1 patient showed signs of mechanical loosening as the prosthesis continued to migrate, reaching 3.2 nun of total motion at 4-year follow-up. RSA did not show any deformation in the polyethylene except for the case of loosening. The clinical results were excellent and good according to the Hospital for Special Surgery scoring system. No correlation was found among demographic, clinical, and RSA data.
引用
收藏
页码:556 / 561
页数:6
相关论文
共 28 条
[1]  
Ahlb_ack S., 1968, ACTA RADIOL SCAND S, P7, DOI 10.1148/23.1.134
[2]   RADIOLUCENT ZONE IN ARTHROPLASTY OF KNEE [J].
AHLBERG, A ;
LINDEN, B .
ACTA ORTHOPAEDICA SCANDINAVICA, 1977, 48 (06) :687-690
[3]   UNICOMPARTMENTAL REPLACEMENT AND HIGH TIBIAL OSTEOTOMY FOR OSTEOARTHRITIS OF THE KNEE - A COMPARATIVE-STUDY AFTER 5-10 YEARS FOLLOW-UP [J].
BROUGHTON, NS ;
NEWMAN, JH ;
BAILY, RAJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :447-452
[4]  
CAMERON HU, 1982, CLIN ORTHOP RELAT R, V170, P141
[5]   FAILURE OF TOTAL KNEE ARTHROPLASTY DUE TO LOOSENING AND DEFORMATION OF TIBIAL COMPONENT [J].
DUCHEYNE, P ;
KAGAN, A ;
LACEY, JA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :384-391
[6]   SOFT-TISSUE BALANCE AND ALIGNMENT IN MEDIAL UNICOMPARTMENTAL KNEE ARTHROPLASTY [J].
EMERSON, RH ;
HEAD, WC ;
PETERS, PC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (06) :807-810
[7]   UNICOMPARTMENTAL ARTHROPLASTY OF THE KNEE - A FOLLOW-UP OF 3 TO 9 YEARS [J].
INGLIS, GS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (05) :682-684
[8]  
INSALL JN, 1982, CLIN ORTHOP RELAT R, V170, P123
[9]   COMPARTMENTAL ARTHROPLASTY FOR GONARTHROSIS [J].
JONSSON, GT .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 :1-111
[10]   MICROMOTION OF FEMORAL STEMS IN TOTAL HIP-ARTHROPLASTY - A RANDOMIZED STUDY OF CEMENTED, HYDROXYAPATITE-COATED, AND POROUS-COATED STEMS WITH ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS [J].
KARRHOLM, J ;
MALCHAU, H ;
SNORRASON, F ;
HERBERTS, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (11) :1692-1705