Bicuspid aortic valve hemodynamics induces abnormal medial remodeling in the convexity of porcine ascending aortas

被引:54
作者
Atkins, Samantha K. [1 ]
Cao, Kai [1 ]
Rajamannan, Nalini M. [2 ]
Sucosky, Philippe [3 ]
机构
[1] Univ Notre Dame, Dept Aerosp & Mech Engn, Notre Dame, IN 46556 USA
[2] Mayo Clin, Sch Med, Rochester, MN USA
[3] Univ Notre Dame, Dept Aerosp & Mech Engn, Eck Inst Global Hlth, Notre Dame, IN 46556 USA
基金
美国国家科学基金会;
关键词
Bicuspid aortic valve; Aortic disease; Fluid-structure interaction modeling; Fluid shear stress; Matrix metalloproteinases; WALL-SHEAR-STRESS; SMOOTH-MUSCLE-CELLS; BLOOD-FLOW; ENDOTHELIAL-CELLS; MATRIX METALLOPROTEINASE-2; SIGNAL-TRANSDUCTION; EXPRESSION; DILATATION; PATTERNS; ANEURYSMS;
D O I
10.1007/s10237-014-0567-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The type-I bicuspid aortic valve (BAV), which differs from the normal tricuspid aortic valve (TAV) most commonly by left-right coronary cusp fusion, is frequently associated with secondary aortopathies. While BAV aortic dilation has been linked to a genetic predisposition, hemodynamics has emerged as a potential alternate etiology. However, the link between BAV hemodynamics and aortic medial degeneration has not been established. The objective of this study was to compare the regional wall shear stresses (WSS) in a TAV and BAV ascending aorta (AA) and to isolate ex vivo their respective impact on aortic wall remodeling. The WSS environments generated in the convex region of a TAV and BAV AA were predicted through fluid-structure interaction (FSI) simulations in an aorta model subjected to both valvular flows. Remodeling of porcine aortic tissue exposed to TAV and BAV AA WSS for 48 h in a cone-and-plate bioreactor was investigated via immunostaining, immunoblotting and zymography. FSI simulations revealed the existence of larger and more unidirectional WSS in the BAV than in the TAV AA convexity. Exposure of normal aortic tissue to BAV AA WSS resulted in increased MMP-2 and MMP-9 expressions and MMP-2 activity but similar fibrillin-1 content and microfibril organization relative to the TAV AA WSS treatment. This study confirms the sensitivity of aortic tissue to WSS abnormalities and demonstrates the susceptibility of BAV hemodynamic stresses to focally mediate aortic medial degradation. The results provide compelling support to the important role of hemodynamics in BAV secondary aortopathy.
引用
收藏
页码:1209 / 1225
页数:17
相关论文
共 66 条
[1]   Medial degeneration does not involve uniformly the whole ascending aorta: morphological, biochemical and clinical correlations [J].
Agozzino, L ;
Ferraraccio, F ;
Esposito, S ;
Trocciola, A ;
Parente, A ;
Della Corte, A ;
De Feo, M ;
Cotrufo, M .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (04) :675-682
[2]  
[Anonymous], 2010, Cardiovasc. Eng. Technol, DOI [DOI 10.1007/S13239-010-0015-5, 10.1007/s13239-010-0015-5]
[3]   Bicuspid Aortic Valve Is Associated With Altered Wall Shear Stress in the Ascending Aorta [J].
Barker, Alex J. ;
Markl, Michael ;
Buerk, Jonas ;
Lorenz, Ramona ;
Bock, Jelena ;
Bauer, Simon ;
Schulz-Menger, Jeanette ;
von Knobelsdorff-Brenkenhoff, Florian .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (04) :457-466
[4]   The role of hemodynamics in bicuspid aortic valve disease [J].
Barker, Alex J. ;
Markl, Michael .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) :805-806
[5]   Quantification of Hemodynamic Wall Shear Stress in Patients with Bicuspid Aortic Valve Using Phase-Contrast MRI [J].
Barker, Alex J. ;
Lanning, Craig ;
Shandas, Robin .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (03) :788-800
[6]   A fluid-structure interaction finite element analysis of pulsatile blood flow through a compliant stenotic artery [J].
Bathe, M ;
Kamm, RD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (04) :361-369
[7]   Different hemodynamic stress of the ascending aorta wall in patients with bicuspid and tricuspid aortic valve [J].
Bauer, M ;
Siniawski, H ;
Pasic, M ;
Schaumann, B ;
Hetzer, R .
JOURNAL OF CARDIAC SURGERY, 2006, 21 (03) :218-220
[8]   Effects of Two Complex Hemodynamic Stimulation Profiles on Hemostatic Genes in a Vessel-Like Environment [J].
Bergh, N. ;
Ulfhammer, E. ;
Karlsson, L. ;
Jern, S. .
ENDOTHELIUM-JOURNAL OF ENDOTHELIAL CELL RESEARCH, 2008, 15 (5-6) :231-238
[9]   Protein kinases as mediators of fluid shear stress stimulated signal transduction in endothelial cells: A hypothesis for calcium-dependent and calcium-independent events activated by flow [J].
Berk, BC ;
Corson, MA ;
Peterson, TE ;
Tseng, H .
JOURNAL OF BIOMECHANICS, 1995, 28 (12) :1439-1450
[10]   Aortic Dilation in Bicuspid Aortic Valve Disease Flow Pattern Is a Major Contributor and Differs With Valve Fusion Type [J].
Bissell, Malenka M. ;
Hess, Aaron T. ;
Biasiolli, Luca ;
Glaze, Steffan J. ;
Loudon, Margaret ;
Pitcher, Alex ;
Davis, Anne ;
Prendergast, Bernard ;
Markl, Michael ;
Barker, Alex J. ;
Neubauer, Stefan ;
Myerson, Saul G. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (04) :499-507