A systematic approach to determine the fouling index for a RO/NF membrane process

被引:60
作者
Choi, June-Seok [1 ]
Hwang, Tae-Mun [1 ]
Lee, Sangho [1 ]
Hong, Seungkwan [1 ]
机构
[1] Korea Univ, Dept Civil Engn, Seoul, South Korea
关键词
Desalination; Reverse osmosis; Nanofiltration; Fouling index; Pretreatment; REVERSE-OSMOSIS; SURFACE-WATER; ULTRAFILTRATION; MICROFILTRATION; NANOFILTRATION; PRETREATMENT;
D O I
10.1016/j.desal.2008.01.042
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A membrane fouling index such as the silt density index (SDI) and modified fouling index (MFI) is an important parameter in design and operation of reverse osmosis (RO) and nanofiltration (NF) membrane processes for desalination. Nevertheless, SDI and MFI often fail to predict actual membrane fouling due to their limited capability to measure fouling potential by colloidal deposition and organic adsorption. In this Study, a novel method to determine fouling index was attempted using a set of different membrane filters for better prediction of RO/NF fouling potential. Three MF/UF membranes were used for MFI tests in order to increase sensitivity to fouling potential of particles, hydrophobic organics, and sub-micron colloids. The fouling indices determined using different membrane filters were compared with RO filtration results. Experimental results indicated that fouling indices using different test membranes showed variable results for untreated and pretreated waters. Nevertheless, no single method was sufficient for accurate measurement or fouling potential. Accordingly, a new fouling index (CFI: combined fouling index) was developed by combining various fouling indices. The CFI exhibited good agreement with experimental data compared with other fouling indices Such as SDI, MFI, and MFI-UF.
引用
收藏
页码:117 / 127
页数:11
相关论文
共 14 条
[1]  
*APHA AWWA WEF, 2005, STAND EX WAT WAST
[2]   Applications of the MFI-UF to measure and predict particulate fouling in RO systems [J].
Boerlage, SFE ;
Kennedy, M ;
Aniye, MP ;
Schippers, JC .
JOURNAL OF MEMBRANE SCIENCE, 2003, 220 (1-2) :97-116
[3]   Integrated multi-objective membrane systems for surface water treatment: pretreatment of reverse osmosis by conventional treatment and ultrafiltration [J].
Kruithof, JC ;
Schippers, JC ;
Kamp, PC ;
Folmer, HC ;
Hofman, JAMH .
DESALINATION, 1998, 117 (1-3) :37-48
[4]   Microfiltration and ultrafiltration as a pretreatment for nanofiltration of surface water [J].
Lee, S ;
Lee, CH .
SEPARATION SCIENCE AND TECHNOLOGY, 2006, 41 (01) :1-23
[5]  
Mallevialle J., 1996, WATER TREATMENT MEMB
[6]  
Nilson JA, 1996, J AM WATER WORKS ASS, V88, P53
[7]   Variation and prediction of membrane fouling index under various feed water characteristics [J].
Park, Chanhyuk ;
Kim, Hana ;
Hong, Seungkwan ;
Choi, Suing-Il .
JOURNAL OF MEMBRANE SCIENCE, 2006, 284 (1-2) :248-254
[8]   Characterizations of the colloidal and microbial organic matters with respect to membrane foulants [J].
Park, N ;
Kwon, B ;
Kim, SD ;
Cho, JW .
JOURNAL OF MEMBRANE SCIENCE, 2006, 275 (1-2) :29-36
[9]   PREDICTING FLUX DECLINE OF REVERSE-OSMOSIS MEMBRANES [J].
SCHIPPERS, JC ;
HANEMAAYER, JH ;
SMOLDERS, CA ;
KOSTENSE, A .
DESALINATION, 1981, 38 (1-3) :339-348
[10]   MODIFIED FOULING INDEX, A METHOD OF DETERMINING THE FOULING CHARACTERISTICS OF WATER [J].
SCHIPPERS, JC ;
VERDOUW, J .
DESALINATION, 1980, 32 (1-3) :137-148