Copper oxide and carbon nano-fragments modified glassy carbon electrode as selective electrochemical sensor for simultaneous determination of catechol and hydroquinone in real-life water samples

被引:79
作者
Alshahrani, Lina Abdullah [1 ]
Liu, Lingyu [1 ]
Sathishkumar, Palanivel [1 ]
Nan, Junmin [1 ]
Gu, Feng Long [1 ]
机构
[1] South China Normal Univ, Sch Chem & Environm, Minist Educ, Key Lab Theoret Chem Environm, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon nano-fragments; Copper oxide; Catechol; Hydroquinone; Electrochemical sensor; REDUCED GRAPHENE OXIDE; DIHYDROXYBENZENE ISOMERS; PHENOLIC-COMPOUNDS; NANOPARTICLES; NANOCOMPOSITE; GREEN; COMPOSITES; OXIDATION; HYDROGEL; BEHAVIOR;
D O I
10.1016/j.jelechem.2018.03.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication of robust sensors for the monitoring of emerging contaminants in real-life water samples has received much attention. In this study, copper oxide and carbon nano-fragment modified glassy carbon electrode (CuO-CNF/GCE) based electrochemical sensor was developed for the simultaneous monitoring of dihydroxybenzene isomers such as catechol (CC) and hydroquinone (HQ). The structural and morphological characterization of CuO-CNF/GCE was done by scanning electron microscopy - energy dispersive X-ray (SEM-EDX), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD). The electrochemical oxidation of HQ and CC was investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The CuO-CNF/GCE exhibited high current sensitivity for CC and HQ. The oxidation peak currents of CC at the CuO-CNF/GCE were linear function of concentration 0 mu M to 150 mu M, with detection limit of 2 mu M (at a signal-to-noise ratio of 3) (R-2 = 0.997) and the oxidation peak currents of HQ were linear function of concentration 3 mu M to 80 mu M, with 1 mu M detection limit (S/N = 3) (R-2 = 0.995). The CuO-CNP/GCE was successfully used for detecting the two dihydroxybenzene isomers in real-life water samples with high selectivity.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 50 条
[21]   Simultaneous Determination of Hydroquinone and Catechol Using Poly(p-aminobenzoic acid) Modified Glassy Carbon Electrode [J].
Yang, Ping ;
Zhu, Qiyong ;
Chen, Yonghong ;
Wang, Fengwu .
JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 113 (05) :2881-2886
[22]   An electrochemically aminated glassy carbon electrode for simultaneous determination of hydroquinone and catechol [J].
Wang, Xiuyun ;
Xi, Min ;
Guo, Mengmeng ;
Sheng, Fangmeng ;
Xiao, Guang ;
Wu, Shuo ;
Uchiyama, Shunichi ;
Matsuura, Hiroaki .
ANALYST, 2016, 141 (03) :1077-1082
[23]   Electrocatalytic oxidation and simultaneous determination of catechol and hydroquinone at a novel carbon nano-fragment modified glassy carbon electrode [J].
Zhang, Chuyi ;
Zeng, Lixuan ;
Zhu, Xiaohua ;
Yu, Chumei ;
Zuo, Xiaoxi ;
Xiao, Xin ;
Nan, Junmin .
ANALYTICAL METHODS, 2013, 5 (09) :2203-2208
[24]   A graphene oxide-mesoporous MnO2 nanocomposite modified glassy carbon electrode as a novel and efficient voltammetric sensor for simultaneous determination of hydroquinone and catechol [J].
Gan, Tian ;
Sun, Junyong ;
Huang, Kejing ;
Song, Li ;
Li, Youmei .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 :412-418
[25]   Mesoporous cobalto-cobaltic oxide modified glassy carbon electrode for simultaneous detection of hydroquinone and catechol [J].
Cui, Shiqiang ;
Li, Li ;
Ding, Yaping ;
Zhang, Jiangjiang .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 782 :225-232
[26]   Simultaneous Determination of Hydroquinone, Catechol and Resorcinol Based on Graphene/Cobalt Hexacyanoferrate Modified Glassy Carbon Electrode [J].
Huang Kejing ;
Yu Sheng ;
Wang Lan ;
Gan Tian ;
Li Mei .
ACTA CHIMICA SINICA, 2012, 70 (06) :735-740
[27]   Simultaneous determination of hydroquinone and catechol based on glassy carbon electrode modified with gold-graphene nanocomposite [J].
Ma, Xuemei ;
Liu, Zhaona ;
Qiu, Cuicui ;
Chen, Ting ;
Ma, Houyi .
MICROCHIMICA ACTA, 2013, 180 (5-6) :461-468
[28]   Determination of Catechol and Hydroquinone by Using Perilla frutescens Activated Carbon Modified Glassy Carbon Electrode [J].
Zheng, Meiqin ;
Zhu, Jingjing ;
Fan, Rongrong ;
Wang, Yujie ;
Lv, Zhaojun ;
Han, Yongming ;
Peng, Jun ;
Zheng, Xinyu ;
Lin, Ruiyu .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2020, 31 (01) :25-32
[29]   A glassy carbon electrode modified with cerium phosphate nanotubes for the simultaneous determination of hydroquinone, catechol and resorcinol [J].
Li, Zhen ;
Yue, Yuhua ;
Hao, Yanjun ;
Feng, Shun ;
Zhou, Xianli .
MICROCHIMICA ACTA, 2018, 185 (04)
[30]   Simultaneous Determination of Hydroquinone and Catechol at Poly-histidine Film Modified Glassy Carbon Electrode [J].
Yang, Qiu-xia ;
Sui, Wei-ping ;
Fan, Da-wei ;
Li, Guo-bao .
ADVANCES IN CHEMICAL ENGINEERING III, PTS 1-4, 2013, 781-784 :89-92