Copper oxide and carbon nano-fragments modified glassy carbon electrode as selective electrochemical sensor for simultaneous determination of catechol and hydroquinone in real-life water samples

被引:79
|
作者
Alshahrani, Lina Abdullah [1 ]
Liu, Lingyu [1 ]
Sathishkumar, Palanivel [1 ]
Nan, Junmin [1 ]
Gu, Feng Long [1 ]
机构
[1] South China Normal Univ, Sch Chem & Environm, Minist Educ, Key Lab Theoret Chem Environm, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon nano-fragments; Copper oxide; Catechol; Hydroquinone; Electrochemical sensor; REDUCED GRAPHENE OXIDE; DIHYDROXYBENZENE ISOMERS; PHENOLIC-COMPOUNDS; NANOPARTICLES; NANOCOMPOSITE; GREEN; COMPOSITES; OXIDATION; HYDROGEL; BEHAVIOR;
D O I
10.1016/j.jelechem.2018.03.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication of robust sensors for the monitoring of emerging contaminants in real-life water samples has received much attention. In this study, copper oxide and carbon nano-fragment modified glassy carbon electrode (CuO-CNF/GCE) based electrochemical sensor was developed for the simultaneous monitoring of dihydroxybenzene isomers such as catechol (CC) and hydroquinone (HQ). The structural and morphological characterization of CuO-CNF/GCE was done by scanning electron microscopy - energy dispersive X-ray (SEM-EDX), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD). The electrochemical oxidation of HQ and CC was investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The CuO-CNF/GCE exhibited high current sensitivity for CC and HQ. The oxidation peak currents of CC at the CuO-CNF/GCE were linear function of concentration 0 mu M to 150 mu M, with detection limit of 2 mu M (at a signal-to-noise ratio of 3) (R-2 = 0.997) and the oxidation peak currents of HQ were linear function of concentration 3 mu M to 80 mu M, with 1 mu M detection limit (S/N = 3) (R-2 = 0.995). The CuO-CNP/GCE was successfully used for detecting the two dihydroxybenzene isomers in real-life water samples with high selectivity.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 50 条
  • [1] Graphene/iridium(III) dimer complex composite modified glassy carbon electrode as selective electrochemical sensor for determination of hydroquinone in real-life water samples
    Mohd Yazid, Siti Nur Akmar
    Md Isa, Illyas
    Ali, Noorshida Mohd
    Hashim, Norhayati
    Saidin, Mohamad Idris
    Ahmad, Mohamad Syahrizal
    Asiri, Abdullah M.
    Khan, Anish
    Zainul, Rahadian
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (11) : 2607 - 2624
  • [2] Electrochemical Sensor for Simple and Sensitive Determination of Hydroquinone in Water Samples Using Modified Glassy Carbon Electrode
    Karami-Kolmoti, Parisa
    Beitollahi, Hadi
    Modiri, Sina
    BIOMEDICINES, 2023, 11 (07)
  • [3] An Electrochemical Sensor Based on Carbon Nano-Fragments and β-cyclodextrin Composite-Modified Glassy Carbon Electrode for the Determination of Rutin
    Zhu, Xiaohua
    Jiao, Qifang
    Zuo, Xiaoxi
    Xiao, Xin
    Liang, Yong
    Nan, Junmin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (10) : H699 - H703
  • [4] Simultaneous Determination of Catechol and Hydroquinone on Nano-Co/L-Cysteine Modified Glassy Carbon Electrode
    Huang, Baomei
    Yao, Chengwei
    Wang, Enyang
    Du, Shizhang
    Yang, Jing
    Lu, Xiaoquan
    ELECTROANALYSIS, 2022, 34 (02) : 405 - 414
  • [5] Simultaneous determination of hydroquinone and catechol using a modified glassy carbon electrode by ruthenium red/carbon nanotube
    Foroughi, Mohammad Mehdi
    Noroozifar, Meissam
    Khorasani-Motlagh, Mozhgan
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2015, 12 (07) : 1139 - 1147
  • [6] Simultaneous Determination of Hydroquinone and Catechol at an Activated Glassy Carbon Electrode
    Ahammad, A. J. Saleh
    Sarker, Subrata
    Rahman, Md Aminur
    Lee, Jae-Joon
    ELECTROANALYSIS, 2010, 22 (06) : 694 - 700
  • [7] Electrochemical behavior of catechol, resorcinol and hydroquinone at graphene-chitosan composite film modified glassy carbon electrode and their simultaneous determination in water samples
    Yin, Huanshun
    Zhang, Qingming
    Zhou, Yunlei
    Ma, Qiang
    Liu, Tao
    Zhu, Lusheng
    Ai, Shiyun
    ELECTROCHIMICA ACTA, 2011, 56 (06) : 2748 - 2753
  • [8] Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes
    Qi, HL
    Zhang, CX
    ELECTROANALYSIS, 2005, 17 (10) : 832 - 838
  • [9] Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode
    Ahammad, A. J. Saleh
    Rahman, Md Mahbubur
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    ELECTROCHIMICA ACTA, 2011, 56 (14) : 5266 - 5271
  • [10] Simultaneous determination of catechol and hydroquinone using electrospun carbon nanofibers modified electrode
    Guo, Qiaohui
    Huang, Jianshe
    Chen, Puqing
    Liu, Yang
    Hou, Haoqing
    You, Tianyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 163 (01) : 179 - 185