Effects of discharge chamber length on the negative ion generation in volume-produced negative hydrogen ion source

被引:18
作者
Chung, Kyoung-Jae [1 ]
Jung, Bong-Ki [2 ]
An, YoungHwa [2 ]
Dang, Jeong-Jeung [2 ]
Hwang, Y. S. [1 ,2 ]
机构
[1] Seoul Natl Univ, Ctr Adv Res Fus Reactor Engn, Seoul 151744, South Korea
[2] Seoul Natl Univ, Dept Nucl Engn, Seoul 151744, South Korea
基金
新加坡国家研究基金会;
关键词
PLASMA; STATE;
D O I
10.1063/1.4842316
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In a volume-produced negative hydrogen ion source, control of electron temperature is essential due to its close correlation with the generation of highly vibrationally excited hydrogen molecules in the heating region as well as the generation of negative hydrogen ions by dissociative attachment in the extraction region. In this study, geometric effects of the cylindrical discharge chamber on negative ion generation via electron temperature changes are investigated in two discharge chambers with different lengths of 7.5 cm and 11 cm. Measurements with a radio-frequency-compensated Langmuir probe show that the electron temperature in the heating region is significantly increased by reducing the length of the discharge chamber due to the reduced effective plasma size. A particle balance model which is modified to consider the effects of discharge chamber configuration on the plasma parameters explains the variation of the electron temperature with the chamber geometry and gas pressure quite well. Accordingly, H- ion density measurement with laser photo-detachment in the short chamber shows a few times increase compared to the longer one at the same heating power depending on gas pressure. However, the increase drops significantly as operating gas pressure decreases, indicating increased electron temperatures in the extraction region degrade dissociative attachment significantly especially in the low pressure regime. It is concluded that the increase of electron temperature by adjusting the discharge chamber geometry is efficient to increase H- ion production as long as low electron temperatures are maintained in the extraction region in volume-produced negative hydrogen ion sources. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:4
相关论文
共 10 条
[1]   Wave frequency dependence of H- ion production and extraction in a transformer coupled plasma H- ion source at SNU [J].
An, YoungHwa ;
Cho, WonHwi ;
Chung, Kyoung-Jae ;
Lee, Kern ;
Jang, SeungBin ;
Lee, Seok-Geun ;
Hwang, Y. S. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02)
[2]   Enhanced surface production in H- ion sources by introducing a negatively biased secondary electrode [J].
An, YoungHwa ;
Jung, BongKi ;
Hwang, Y. S. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02)
[3]  
[Anonymous], 2005, PRINCIPLES PLASMA DI, DOI [10.1002/0471724254, DOI 10.1002/0471724254]
[4]   NUMERICAL-SIMULATION OF HYDROGEN-ION SPECIES IN THE STEADY-STATE PLASMA OF A LOW-PRESSURE ION-SOURCE [J].
FUKUMASA, O ;
ITATANI, R ;
SAEKI, S .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1985, 18 (12) :2433-2449
[6]  
Hong IS, 2006, J KOREAN PHYS SOC, V48, P716
[7]   H- ion beam extraction from a transformer coupled plasma source with triode extraction system [J].
Jeong, HS ;
Kim, YJ ;
Hong, IS ;
Park, DH ;
Hwang, YS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03)
[8]   Development of a high-current helicon ion source with high monatomic fraction for the application of neutron generators [J].
Jung, H. D. ;
Park, J. Y. ;
Chung, K. J. ;
Hwang, Y. S. .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2007, 35 (05) :1476-1479
[9]   H- laser photodetachment at 1064, 532, and 355 nm in plasma [J].
Nishiura, M ;
Sasao, M ;
Bacal, M .
JOURNAL OF APPLIED PHYSICS, 1998, 83 (06) :2944-2949
[10]   Global model of a radiofrequency H2 plasma in DENISE [J].
Zorat, R ;
Goss, J ;
Boilson, D ;
Vender, D .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 2000, 9 (02) :161-168