Accelerated Phase-Contrast MR Imaging: Comparison of k-t BLAST With SENSE and Doppler Ultrasound for Velocity and Flow Measurements in the Aorta

被引:21
作者
Stadlbauer, Andreas [1 ,2 ]
van der Riet, Wilma [3 ]
Globits, Sebastian [4 ]
Crelier, Gerard [5 ]
Salomonowitz, Erich [1 ]
机构
[1] Landesklinikum St Poelten, Dept Radiol, MR Phys Grp, A-3100 St Polten, Austria
[2] Univ Erlangen Nurnberg, Dept Neurosurg, Nurnberg, Germany
[3] EMRIC, Strasbourg, France
[4] Landesklinikum St Poelten, Dept Internal Med 3, A-3100 St Polten, Austria
[5] Univ & ETH, Inst Biomed Engn, Zurich, Switzerland
关键词
phase contrast; SENSE; k-t BLAST; velocity mapping; aorta; STATE FREE PRECESSION; SPEED-UP TECHNIQUE; MAGNETIC-RESONANCE; SHUNT QUANTIFICATION; BLOOD-FLOW; FEASIBILITY; VALIDATION; SPACE; RECONSTRUCTION;
D O I
10.1002/jmri.21706
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate differences in velocity and flow measurements in the aorta between accelerated phase-contrast (PC) magnetic resonance imaging (MRI) using SENSE and k-t BLAST and In peal, velocity to Doppler ultrasound. Materials and Methods: Two-dimensional PC-MRI perpendicular to the ascending and descending aorta was performed in I I volunteers using SENSE (R 2) and k-t BLAST (2-, 4-, 6-, and 8-fold). Peak velocity, mean velocity, and stroke Volume of the accelerated PC-MRI experiments were correlated. Peak velocities were compared to Doppler ultrasound. Results: All acceleration techniques showed significant correlations for peak velocity with Doppler ultrasound. However, k-t BLAST 6 and 8 showed a significant underestimation. Strong correlations between SENSE and k-t BLAST were found for all three parameters. Significant differences in peak velocity were found between SENSE and all k-t BLAST experiments, but not for 2-fold k-t. BLAST in the ascending aorta, and 2- and 4-fold k-t BLAST in the descending aorta. For mean velocity no significant differences were found. Stroke volume showed significant differences for all k-t BLAST experiments in the ascending and for 6- and 8-fold k-t BLAST in the descending aorta. Conclusion: Peak velocity of accelerated PC-MRI correlated with CW Doppler measurements, but high k-t BLAST acceleration factors lead to a significant underestimation, SENSE with R = 2 and 2-fold k-t BLAST are most highly correlated in phase-contrast flow measurements.
引用
收藏
页码:817 / 824
页数:8
相关论文
共 29 条
[11]   Accelerated dynamic Fourier velocity encoding by exploiting velocity-spatio-temporal correlations [J].
Hansen, MS ;
Baltes, C ;
Tsao, J ;
Kozerke, S ;
Pruessmann, KP ;
Boesiger, P ;
Pedersen, EM .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 17 (02) :86-94
[12]   On the influence of training data quality in k-t BLAST reconstruction [J].
Hansen, MS ;
Kozerke, S ;
Pruessmann, KP ;
Boesiger, P ;
Pedersen, EM ;
Tsao, J .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) :1175-1183
[13]   A practical approach to the quantification of valvular regurgitation [J].
Jacob R. ;
Stewart W.J. .
Current Cardiology Reports, 2007, 9 (2) :105-111
[14]   Accelerated 4D dobutamine stress MR imaging with k-t BLAST: Feasibility and diagnostic performance [J].
Jahnke, Cosima ;
Paetsch, Ingo ;
Gebker, Rolf ;
Bornstedt, Axel ;
Fleck, Eckart ;
Nagel, Eike .
RADIOLOGY, 2006, 241 (03) :718-728
[15]   Flow measurement by magnetic resonance: A unique asset worth optimising [J].
Kilner, Philip J. ;
Gatehouse, Peter D. ;
Firmin, David N. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (04) :723-728
[16]   Flow volume and shunt quantification in pediatric congenital heart disease by real-time magnetic resonance velocity mapping -: A validation study [J].
Körperich, H ;
Gieseke, J ;
Barth, P ;
Hoogeveen, R ;
Esdorn, H ;
Peterschröder, A ;
Meyer, H ;
Beerbaum, P .
CIRCULATION, 2004, 109 (16) :1987-1993
[17]   Accelerating cardiac Cine 3D Imaging using k-t BLAST [J].
Kozerke, S ;
Tsao, J ;
Razavi, R ;
Boesiger, P .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) :19-26
[18]  
Kozerke Sebastian, 2004, Top Magn Reson Imaging, V15, P161, DOI 10.1097/01.rmr.0000132789.84706.9d
[19]   Peak velocity and flow quantification validation for sensitivity-encoded phase-contrast MR imaging [J].
Lew, Calvin D. ;
Alley, Marcus T. ;
Bammer, Roland ;
Spielman, Daniel M. ;
Chan, Frandics P. .
ACADEMIC RADIOLOGY, 2007, 14 (03) :258-269
[20]   Real-time Fourier velocity encoding: An in vivo evaluation [J].
Macgowan, CK ;
Kellenberger, CJ ;
Detsky, JS ;
Roman, K ;
Yoo, SJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) :297-304