Accelerated Phase-Contrast MR Imaging: Comparison of k-t BLAST With SENSE and Doppler Ultrasound for Velocity and Flow Measurements in the Aorta

被引:21
作者
Stadlbauer, Andreas [1 ,2 ]
van der Riet, Wilma [3 ]
Globits, Sebastian [4 ]
Crelier, Gerard [5 ]
Salomonowitz, Erich [1 ]
机构
[1] Landesklinikum St Poelten, Dept Radiol, MR Phys Grp, A-3100 St Polten, Austria
[2] Univ Erlangen Nurnberg, Dept Neurosurg, Nurnberg, Germany
[3] EMRIC, Strasbourg, France
[4] Landesklinikum St Poelten, Dept Internal Med 3, A-3100 St Polten, Austria
[5] Univ & ETH, Inst Biomed Engn, Zurich, Switzerland
关键词
phase contrast; SENSE; k-t BLAST; velocity mapping; aorta; STATE FREE PRECESSION; SPEED-UP TECHNIQUE; MAGNETIC-RESONANCE; SHUNT QUANTIFICATION; BLOOD-FLOW; FEASIBILITY; VALIDATION; SPACE; RECONSTRUCTION;
D O I
10.1002/jmri.21706
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate differences in velocity and flow measurements in the aorta between accelerated phase-contrast (PC) magnetic resonance imaging (MRI) using SENSE and k-t BLAST and In peal, velocity to Doppler ultrasound. Materials and Methods: Two-dimensional PC-MRI perpendicular to the ascending and descending aorta was performed in I I volunteers using SENSE (R 2) and k-t BLAST (2-, 4-, 6-, and 8-fold). Peak velocity, mean velocity, and stroke Volume of the accelerated PC-MRI experiments were correlated. Peak velocities were compared to Doppler ultrasound. Results: All acceleration techniques showed significant correlations for peak velocity with Doppler ultrasound. However, k-t BLAST 6 and 8 showed a significant underestimation. Strong correlations between SENSE and k-t BLAST were found for all three parameters. Significant differences in peak velocity were found between SENSE and all k-t BLAST experiments, but not for 2-fold k-t. BLAST in the ascending aorta, and 2- and 4-fold k-t BLAST in the descending aorta. For mean velocity no significant differences were found. Stroke volume showed significant differences for all k-t BLAST experiments in the ascending and for 6- and 8-fold k-t BLAST in the descending aorta. Conclusion: Peak velocity of accelerated PC-MRI correlated with CW Doppler measurements, but high k-t BLAST acceleration factors lead to a significant underestimation, SENSE with R = 2 and 2-fold k-t BLAST are most highly correlated in phase-contrast flow measurements.
引用
收藏
页码:817 / 824
页数:8
相关论文
共 29 条
  • [1] Evaluation of global cardiac functional parameters using single-breath-hold three-dimensional cine steady-state free precession MR imaging with two types of speed-up techniques: Comparison with two-dimensional cine imaging
    Amano, Yasuo
    Suzuki, Yuriko
    van Cauteren, Marc
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2008, 32 (01) : 61 - 66
  • [2] Brain hydrodynamics study by phase-contrast magnetic resonance imaging and transcranial color Doppler
    Baledent, Olivier
    Fin, Loic
    Khuoy, Louis
    Ambarki, Khalid
    Gauvin, Anne-Cecile
    Gondry-Jouet, Catherine
    Meyer, Marc-Etienne
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) : 995 - 1004
  • [3] Accelerating cine phase-contrast flow measurements using k-t BLAST and k-t SENSE
    Baltes, C
    Kozerke, S
    Hansen, MS
    Pruessmann, KP
    Tsao, J
    Boesiger, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) : 1430 - 1438
  • [4] Blood flow quantification in adults by phase-contrast MRI combined with SENSE -: a validation study
    Beerbaum, P
    Körperich, H
    Gieseke, J
    Barth, P
    Peuster, M
    Meyer, H
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (02) : 361 - 369
  • [5] Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding
    Beerbaum, P
    Körperich, H
    Gieseke, J
    Barth, P
    Peuster, M
    Meyer, H
    [J]. CIRCULATION, 2003, 108 (11) : 1355 - 1361
  • [6] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [7] BIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY, TRANSTHORACIC DOPPLER, AND MAGNETIC-RESONANCE-IMAGING IN THE ASSESSMENT OF COARCTATION OF THE AORTA
    ENGVALL, J
    SJOQVIST, L
    NYLANDER, E
    THUOMAS, KA
    WRANNE, B
    [J]. EUROPEAN HEART JOURNAL, 1995, 16 (10) : 1399 - 1409
  • [8] MR myocardial perfusion Imaging with k-space and time broad-use linear acquisition speed-up technique: Feasibility study
    Gebker, Rolf
    Jahnke, Cosima
    Paetsch, Ingo
    Schnackenburg, Bernhard
    Kozerke, Sebastian
    Bornstedt, Axel
    Fleck, Eckart
    Nagel, Eike
    [J]. RADIOLOGY, 2007, 245 (03) : 863 - 871
  • [9] Assessment of left ventricular volumes and mass with fast 3D cine steady-state free precession k-t space broad-use linear acquisition speed-up technique (k-t BLAST)
    Greil, Gerald F.
    Germann, Sabrina
    Kozerke, Sebastian
    Baltes, Christof
    Tsao, Jeffrey
    Urschitz, Michael S.
    Seeger, Achim
    Tangcharoen, Tarinee
    Bialkowsky, Anja
    Miller, Stephan
    Sieverding, Ludger
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) : 510 - 515
  • [10] k-t BLAST reconstruction from non-Cartesian k-t space sampling
    Hansen, MS
    Baltes, C
    Tsao, J
    Kozerke, S
    Pruessmann, KP
    Eggers, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) : 85 - 91