Retention and selectivity of basic drugs on solid-phase extraction sorbents: Application to direct determination of β-blockers in urine

被引:29
作者
Boonjob, Warunya [1 ]
Sklenarova, Hana [1 ]
Lara, Francisco J. [2 ]
Garcia-Campana, Ana M. [2 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic
[2] Univ Granada, Dept Analyt Chem, Fac Sci, E-18071 Granada, Spain
关键词
beta-Blockers; SPE; HPLC; Biological samples; MIP; MOLECULARLY IMPRINTED POLYMER; RESTRICTED ACCESS MATERIALS; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; SAMPLE PREPARATION; BIOLOGICAL-FLUIDS; TRACE LEVELS; PLASMA; PROPRANOLOL; ISOFLAVONES;
D O I
10.1007/s00216-014-7753-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Seven solid phase sorbent materials with reversed-phase, mixed-mode interactions (ion-exchange and reversed-phase), and molecularly imprinted polymers (MIP), namely Oasis HLB, Oasis MAX, Oasis MCX, Bond Elute Plexa, Bond Elute Plexa PAX, Bond Elute Plexa PCX, and SupelMIP sorbents, were investigated. The present study was focused on the retention and elution of pharmaceutically active substances based on several analyte-sorbent interaction properties. Basic drugs, such as beta-blockers (i.e., atenolol, pindolol, acebutolol, metoprolol, labetalol, and propranolol) were selected as the model compounds for this study. These compounds are frequently encountered in anti-doping tests. The extraction efficiencies of the individual sorbents were compared based on the recovery of known amounts of the targeted analytes in a metered elution volume (500 mu L) in three separate elution fractions. The elution efficiency of the total amount of the target analytes on various sorbents was not appreciably influenced by the volume of eluent required for complete elution. Based on the small matrix effects and clear baseline, SupelMIP was the most suitable sorbent for urine analysis. The relative analyte recoveries of the SPE-HPLC procedure proved satisfactory for the range from 94 % to 105 %, with an RSD ranging from 2 % to 4 %. The regression equations for all of the targeted compounds exhibited excellent linearity (r (2) > 0.9991) over the range of 10 to 1000 ng mL(-1). The limits of detection and quantification for the selected beta-blocker compounds in urine were in the ranges of 0.6 to 2.0 ng mL(-1) and 2.0 to 6.7 ng mL(-1), respectively.
引用
收藏
页码:4207 / 4215
页数:9
相关论文
共 27 条
[1]  
Agilent Technologies, 2011, AG BOND EL PLEX POL
[2]   Chiral Separation of β-Adrenergic Blockers in Human Plasma by SPE-HPLC [J].
Ali, Imran ;
Al-Othman, Zeid A. ;
Hussain, Afzal ;
Saleem, Kishwar ;
Aboul-Enein, Hassan Y. .
CHROMATOGRAPHIA, 2011, 73 (3-4) :251-256
[3]   Combined microwave-assisted extraction and continuous solid-phase extraction prior to gas chromatography-mass spectrometry determination of pharmaceuticals, personal care products and hormones in soils, sediments and sludge [J].
Azzouz, Abdelmonaim ;
Ballesteros, Evaristo .
SCIENCE OF THE TOTAL ENVIRONMENT, 2012, 419 :208-215
[4]   Determination of pKa values of active pharmaceutical ingredients [J].
Babic, Sandra ;
Horvat, Alka J. M. ;
Pavlovic, Dragana Mutavdzic ;
Kastelan-Macan, Marija .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (11) :1043-1061
[5]   UHPLC Method for the Simultaneous Determination of β-Blockers, Isoflavones, and Flavonoids in Human Urine [J].
Baranowska, Irena ;
Magiera, Sylwia ;
Baranowski, Jacek .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (10) :764-773
[6]   Online Coupling of Bead Injection Lab-On-Valve Analysis to Gas Chromatography: Application to the Determination of Trace Levels of Polychlorinated Biphenyls in Solid Waste Leachates [J].
Benito Quintana, Jose ;
Boonjob, Warunya ;
Miro, Manuel ;
Cerda, Victor .
ANALYTICAL CHEMISTRY, 2009, 81 (12) :4822-4830
[7]   Flow-through Dispersed Carbon Nanofiber-Based Microsolid-Phase Extraction Coupled to Liquid Chromatography for Automatic Determination of Trace Levels of Priority Environmental Pollutants [J].
Boonjob, Warunya ;
Miro, Manuel ;
Segundo, Marcela A. ;
Cerda, Victor .
ANALYTICAL CHEMISTRY, 2011, 83 (13) :5237-5244
[8]   Online Hyphenation of Multimodal Microsolid Phase Extraction Involving Renewable Molecularly Imprinted and Reversed-Phase Sorbents to Liquid Chromatography for Automatic Multiresidue Assays [J].
Boonjob, Warunya ;
Yu, Yongliang ;
Miro, Manuel ;
Segundo, Marcela A. ;
Wang, Jianhua ;
Cerda, Victor .
ANALYTICAL CHEMISTRY, 2010, 82 (07) :3052-3060
[9]   Multidimensional on-line solid-phase extraction (SPE) using restricted access materials (RAM) in combination with molecular imprinted polymers (MIP) [J].
Boos, KS ;
Fleischer, CT .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (01) :16-20
[10]   Use of a novel cation-exchange restricted-access material for automated sample clean-up prior to the determination of basic drugs in plasma by liquid chromatography [J].
Chiap, P ;
Rbeida, O ;
Christiaens, B ;
Hubert, P ;
Lubda, D ;
Boos, KS ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) :145-155