Does hyoscine butylbromide really improve polyp detection during colonoscopy? A meta-analysis of randomized controlled trials

被引:19
作者
Cui, Pei-Jing [1 ]
Yao, Jing [2 ]
Han, Hua-Zhong [2 ]
Zhao, Yi-Jun [2 ]
Yang, Jun [2 ]
机构
[1] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Geriatr, Shanghai 200025, Peoples R China
[2] Shanghai Jiao Tong Univ, Peoples Hosp 6, Dept Surg, Shanghai 200233, Peoples R China
关键词
Hyoscine butylbromide; Polyp detection; Adenoma detection; Colonoscopy; PLACEBO-CONTROLLED TRIAL; N-BUTYL BROMIDE; ADENOMA MISS RATES; COLORECTAL-CANCER; DOUBLE-BLIND; TANDEM COLONOSCOPY; PREMEDICATION; QUALITY; WITHDRAWAL; BENEFIT;
D O I
10.3748/wjg.v20.i22.7034
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To investigate the benefits of hyoscine butylbromide in polyp detection during colonoscopy by a meta-analysis of available randomized controlled trials (RCTs). METHODS: Databases, including PubMed, EMBASE, the Cochrane Library, and the Science Citation Index up to September 2013, were searched. The primary outcome was polyp detection rate, and the secondary outcome was adenoma detection rate. The meta-analysis was performed using the free software Review Manager. Differences observed between the treated and the control groups were expressed as odds ratio (OR) with a 95% confidence interval (CI). A fixed-effects model was used to pool data when statistical heterogeneity was absent. If statistical heterogeneity was present (P < 0.05), a random-effects model was used. RESULTS: The initial search identified nine articles. After screening, five RCTs with a total of 1998 patients were included in this meta-analysis. Of the five studies, all described a comparison of baseline patient characteristics and showed that there was no statistically significant difference between the two groups. Among the 1998 patients, 1006 received hyoscine butylbromide and 992 were allocated to the control group, and the polyp detection rate was reported. There were no significant differences between the treated and the control group (OR = 1.09, 95%CI: 0.91-1.31, P = 0.33). Four RCTs included 1882 patients, of whom 948 received hyoscine butylbromide, and the adenoma detection rate was reported. There were no significant differences between the treated and the control group (OR = 1.13, 95%CI: 0.92-1.38, P = 0.24). CONCLUSION: The use of hyoscine butylbromide did not significantly improve the polyp detection rate during colonoscopy. (C) 2014 Baishideng Publishing Group Inc. All rights reserved.
引用
收藏
页码:7034 / 7039
页数:6
相关论文
共 35 条
[1]   A prospective study of the technical feasibility of ileoscopy at colonoscopy [J].
Ansari, A ;
Soon, SY ;
Saunders, BP ;
Sanderson, JD .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2003, 38 (11) :1184-1186
[2]  
Behrens C, 2008, CAN ASSOC RADIOL J, V59, P183
[3]   CONTROLLED TRIAL OF PREMEDICATION WITH DICYCLOMINE HYDROCHLORIDE (BENTYL) IN COLONOSCOPY [J].
BOND, JH ;
CHALLY, CH ;
BLACKWOO.WD .
GASTROINTESTINAL ENDOSCOPY, 1974, 20 (02) :61-61
[4]   Role of Intravenous Hyoscine N-Butyl Bromide At the Time of Colonoscopic Withdrawal for Polyp Detection Rates: A Randomized, Double-Blinded, Placebo-Controlled Trial [J].
Byun, Tae Jun ;
Han, Dong Soo ;
Ahn, Sang Bong ;
Cho, Hyun Seok ;
Kim, Tae Yeob ;
Eun, Chang Soo ;
Jeon, Yong Cheol ;
Sohn, Joo Hyun .
GASTROINTESTINAL ENDOSCOPY, 2009, 69 (05) :AB229-AB229
[5]   Sublingual hyoscyamine spray as premedication for colonoscopy: a randomized double-blinded placebo-controlled trial [J].
Chaptini, Louis A. ;
Janec, Eileen M. ;
Seltzer, Gregory ;
Peikin, Steven ;
Elfant, Adam B. .
AMERICAN JOURNAL OF SURGERY, 2008, 196 (01) :51-55
[6]   Hyoscine butylbromide administered at the cecum increases polyp detection: a randomized double-blind placebo-controlled trial [J].
Corte, C. ;
Dahlenburg, L. ;
Selby, W. ;
Griffin, S. ;
Byrne, C. ;
Chua, T. ;
Kaffes, A. .
ENDOSCOPY, 2012, 44 (10) :917-922
[7]   Hyoscine N-Butylbromide Does Not Improve Polyp Detection During Colonoscopy: A Double-Blind Randomized Placebo-Controlled Clinical Trial [J].
Ter Borg, Frank ;
De Brouwer, Esther J. ;
Arbouw, Maurits ;
Van Der Zwet, Wil C. ;
Van Herwaarden, Margot A. ;
Ledeboer, Michiel ;
Jansman, Frank G. .
GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) :168-168
[8]   RISK OF COLORECTAL-CANCER IN ADENOMA-BEARING INDIVIDUALS WITHIN A DEFINED POPULATION [J].
EIDE, TJ .
INTERNATIONAL JOURNAL OF CANCER, 1986, 38 (02) :173-176
[9]   Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study [J].
Froehlich, F ;
Wietlisbach, V ;
Gonvers, JJ ;
Burnand, B ;
Vader, JP .
GASTROINTESTINAL ENDOSCOPY, 2005, 61 (03) :378-384
[10]   Colonoscopy: antispasmodics not only for premedication, but also during endoscope withdrawal? [J].
Froehlich, F .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (03) :379-379