Low-molecular-weight heparin for anti-coagulation after left ventricular assist device implantation

被引:37
|
作者
Sandner, Sigrid E. [1 ]
Riebandt, Julia [1 ]
Haberl, Thomas [1 ]
Mahr, Stephane [1 ]
Rajek, Angela [2 ]
Schima, Heinrich [1 ]
Wieselthaler, George M. [3 ]
Laufer, Guenther [1 ]
Zimpfer, Daniel [1 ]
机构
[1] Med Univ Vienna, Div Cardiac Surg, A-1090 Vienna, Austria
[2] Med Univ Vienna, Div Cardiothorac & Vasc Anesthesia & Crit Care Me, A-1090 Vienna, Austria
[3] Univ Calif San Francisco, Sch Med, Div Adult Cardiothorac Surg, San Francisco, CA USA
来源
关键词
anti-coagulation; low-molecular-weight; ventricular assist device; heart failure; AWAITING HEART-TRANSPLANTATION; UNFRACTIONATED HEPARIN; CONTINUOUS-FLOW; ANTITHROMBOTIC THERAPY; VENOUS THROMBOEMBOLISM; MYOCARDIAL-INFARCTION; ORAL ANTICOAGULANTS; ATRIAL-FIBRILLATION; VALVE REPLACEMENT; ENOXAPARIN;
D O I
10.1016/j.healun.2013.10.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Anti-coagulation is required in patients with left ventricular assist devices (LVADs). We evaluated the feasibility of low-molecular-weight heparin (LMWH) for initiation of anti-coagulation and transitioning to oral anti-coagulation after LVAD implantation. METHODS: This single-center study included 78 consecutive patients who underwent either Thoratec HeartMate II LVAD (n = 27) or HeartWare ventricular assist device (HVAD, n = 51) implantation. The LMWHs enoxaparin (n = 50) and dalteparin (n = 28) were used. LMWH was started within 24 hours post-operatively in 79.5% of patients. No anti-coagulation was given before starting LMWH therapy. LMWH activity was monitored by determination of anti factor Xa levels in plasma. RESULTS: The majority of patients (80.7%) had peak anti-Xa activity within the defined range of efficacy of 0.2 to 0.4 IU/ml by the second day of treatment. Mean effective peak anti-Xa activity was 0.28 +/- 0.06 IU/ml. Mean duration of anti-coagulation with LMWH was 25.8 +/- 18 days. Ischemic strokes were observed in 3 patients (3.8%), with a total of 4 events. Three events occurred while on LMWH, and 1 event occurred during follow-up on oral anti-coagulation. There was 1 fatal stroke. No pump thrombus was observed. Major bleeding was observed in 5 patients (6.4%), with a total of 6 events. Gastrointestinal bleeding was the most common complication (n = 3). There were no fatal bleeding events. CONCLUSIONS: LMWH in the setting of LVAD shows rapid and constant biologic efficacy. Anticoagulation with LMWH appears feasible after LVAD implantation. These findings support further evaluation of LMWH as an alternative to unfractionated heparin in this patient cohort. (C) 2014 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:88 / 93
页数:6
相关论文
共 50 条
  • [11] Impact of inflammation and steroids on anti-coagulation in children supported on a ventricular assist device
    Brandewie, Katie
    Lorts, Angela
    Luchtman-Jones, Lori
    Gao, Zhiqian
    Geer, Becca
    Villa, Chet
    Perry, Tanya
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (04) : 368 - 374
  • [12] Anti-Coagulation Management in Pediatric Ventricular Assist Device: A Quality Improvement Target
    VanderPluym, C.
    O'Connor, M.
    Lorts, A.
    Ploutz, M.
    Peng, D.
    Law, S.
    Zinn, M.
    Niebler, R.
    Rosenthal, D.
    Conway, J.
    Auerbach, S.
    Sutcliffe, D.
    Mehegan, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S22 - S22
  • [13] Portable Compression Device and Low-Molecular-Weight Heparin Compared With Low-Molecular-Weight Heparin for Thromboprophylaxis After Total Joint Arthroplasty
    Edwards, John Z.
    Pulido, Pamela A.
    Ezzet, Kace A.
    Copp, Steven N.
    Walker, Richard H.
    Colwell, Clifford W., Jr.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (08): : 1122 - 1127
  • [14] Ventricular arrhythmias after left ventricular assist device implantation
    Refaat, Marwan
    Chemaly, Elie
    Lebeche, Djamel
    Gwathmey, Judith K.
    Hajjar, Roger J.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (10): : 1246 - 1252
  • [15] In vivo Hemodynamic Evaluation of an Implantable Left Ventricular Assist Device in a Long-term Anti-coagulation Regimen
    Wang, Yaxin
    Smith, P. Alex
    Handy, Kelly M.
    Conger, Jeffrey L.
    Spangler, Taylor
    Lin, Frank
    Chen, Chen
    Costas, Gil
    Elgalad, Abdelmotagaly
    Sampaio, Luiz C.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2589 - 2593
  • [16] Driving After Left Ventricular Assist Device Implantation
    Hanke, Jasmin S.
    Riebandt, Julia
    Wahabzada, Miena
    Nur, Fatma
    Wahabzada, Angela
    Dogan, Guenes
    Feldmann, Christina
    Haverich, Axel
    Popov, Aron-Friedrich
    Zimpfer, Daniel
    Schmitto, Jan D.
    ARTIFICIAL ORGANS, 2018, 42 (07) : 695 - 699
  • [17] Flying after left ventricular assist device implantation
    Hanke, Jasmin S.
    Schmack, Bastian
    Merzah, Ali Saad
    Bounader, Karl
    Chatterjee, Anamika
    Mariani, Silvia
    Li, Tong
    Klautzsch, Erik
    Mueller, Florian
    Homann, Katharina
    Schoede, Alexandra
    Haverich, Axel
    Ruhparwar, Arjang
    Schmitto, Jan D.
    Dogan, Guenes
    ARTIFICIAL ORGANS, 2021, 45 (03) : 230 - 235
  • [18] Dialysis After Left Ventricular Assist Device Implantation
    Tsay, Annie
    Ober, Lori
    Soleimani, Behzad
    Dowling, Robert
    Shouey, Jordan
    Ali, Omaima
    Scanlon, Thomas
    Oblender, Robert
    Eisen, Howard Joel
    JOURNAL OF CARDIAC FAILURE, 2020, 26 (10) : S153 - S154
  • [19] Clinical, Molecular, and Genomic Changes After Left Ventricular Assist Device Implantation
    Hetzer, Roland
    Dandel, Michael
    Knosalla, Christoph
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (24) : 2459 - 2460
  • [20] Left ventricular assist device implantation in patients after left ventricular reconstruction
    Palmen, Meindert
    Braun, Jerry
    Beeres, Saskia L. M. A.
    Klautz, Robert J. M.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 23 (06) : 979 - 981