Characterization of a DAPI-RIT-DAPI System for Gas-Phase Ion/Molecule and Ion/Ion Reactions

被引:5
作者
Lin, Ziqing [1 ]
Tan, Lei [2 ]
Garimella, Sandilya [1 ]
Li, Linfan [1 ]
Chen, Tsung-Chi [1 ]
Xu, Wei [1 ]
Xia, Yu [2 ]
Ouyang, Zheng [1 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
Instrumentation; Discontinuous atmospheric pressure interface (DAPI); Linear ion trap; Ion/molecule reactions; Ion/ion reactions; ION-MOLECULE REACTIONS; ELECTRON-CAPTURE DISSOCIATION; MASS-SPECTROMETRY; INTERNAL ENERGY; TRAP; IONIZATION; PEPTIDES; INSTRUMENTATION; FRAGMENTATION; CHEMISTRY;
D O I
10.1007/s13361-013-0757-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The discontinuous atmospheric pressure interface (DAPI) has been developed as a facile means for efficiently introducing ions generated at atmospheric pressure to an ion trap in vacuum [e.g., a rectilinear ion trap (RIT)] for mass analysis. Introduction of multiple beams of ions or neutral species through two DAPIs into a single RIT has been previously demonstrated. In this study, a home-built instrument with a DAPI-RIT-DAPI configuration has been characterized for the study of gas-phase ion/molecule and ion/ion reactions. The reaction species, including ions or neutrals, can be introduced from both ends of the RIT through the two DAPIs without complicated ion optics or differential pumping stages. The primary reactant ions were isolated prior to reaction and the product ions were mass analyzed after controlled reaction time period. Ion/molecule reactions involving peptide radical ions and proton-transfer ion/ion reactions have been carried out using this instrument. The gas dynamic effect due to the DAPI operation on internal energy deposition and the reactivity of peptide radical ions has been characterized. The DAPI-RIT-DAPI system also has a unique feature for allowing the ion reactions to be carried out at significantly elevated pressures (in 10(-1) Torr range), which has been found to be helpful to speed up the reactions. The viability and flexibility of the DAPI-RIT-DAPI system for the study of gas-phase ion reactions have been demonstrated.
引用
收藏
页码:48 / 56
页数:9
相关论文
共 48 条
  • [1] A quadrupole ion trap mass spectrometer with three independent ion sources for the study of gas-phase ion/ion reactions
    Badman, Ethan R.
    Chrisman, Paul A.
    McLuckey, Scott A.
    [J]. Analytical Chemistry, 2002, 74 (24) : 6237 - 6243
  • [2] Quadrupole mass spectrometry of reactive plasmas
    Benedikt, J.
    Hecimovic, A.
    Ellerweg, D.
    von Keudell, A.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2012, 45 (40)
  • [3] Synchronized Discharge Ionization for Analysis of Volatile Organic Compounds Using a Hand-Held Ion Trap Mass Spectrometer
    Chen, Tsung-Chi
    Ouyang, Zheng
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (03) : 1767 - 1772
  • [4] Study of the efficiency for ion transfer through bent capillaries
    Chen, Tsung-Chi
    Xu, Wei
    Garimella, Sandilya
    Ouyang, Zheng
    [J]. JOURNAL OF MASS SPECTROMETRY, 2012, 47 (11): : 1466 - 1472
  • [5] Metastable atom-activated dissociation mass spectrometry: leucine/isoleucine differentiation and ring cleavage of proline residues
    Cook, Shannon L.
    Collin, Olivier L.
    Jackson, Glen P.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2009, 44 (08): : 1211 - 1223
  • [6] Anion dependence in the partitioning between proton and electron transfer in ion/ion reactions
    Coon, JJ
    Syka, JEP
    Schwartz, JC
    Shabanowitz, J
    Hunt, DF
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 236 (1-3) : 33 - 42
  • [7] The role of electron capture dissociation in biomolecular analysis
    Cooper, HJ
    Håkansson, K
    Marshall, AG
    [J]. MASS SPECTROMETRY REVIEWS, 2005, 24 (02) : 201 - 222
  • [8] ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES
    FENN, JB
    MANN, M
    MENG, CK
    WONG, SF
    WHITEHOUSE, CM
    [J]. SCIENCE, 1989, 246 (4926) : 64 - 71
  • [9] Internal energy and fragmentation of ions produced in electrospray sources
    Gabelica, V
    De Pauw, E
    [J]. MASS SPECTROMETRY REVIEWS, 2005, 24 (04) : 566 - 587
  • [10] Breaking the pumping speed barrier in mass spectrometry: Discontinuous atmospheric pressure interface
    Gao, Liang
    Cooks, R. Graham
    Ouyang, Zheng
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (11) : 4026 - 4032