Refrigerant falling film evaporation review: Description, fluid dynamics and heat transfer

被引:102
作者
Fernandez-Seara, Jose [1 ]
Pardinas, Angel A. [1 ]
机构
[1] Univ Vigo, ETS Ingn Ind, Area Maquinas & Motores Term, Vigo 36310, Spain
关键词
Falling film evaporation; Spray evaporation; Refrigeration; AMMONIA SPRAY EVAPORATOR; PLAIN-TUBE BUNDLE; ENHANCED TUBES; PART II; HORIZONTAL CYLINDER; LIQUID-FILM; PREDICTION; DRYOUT; ONSET; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2013.11.023
中图分类号
O414.1 [热力学];
学科分类号
摘要
Falling film horizontal tube evaporators for refrigeration equipment are an interesting alternative to pool boiling evaporators concerning operation costs, safety, thermodynamic efficiency, charge of refrigerant or size. Plenty of literature works studied falling film evaporation, but for its application in fields such as desalination and petrochemical industry or OTEC. This review focuses mainly on those works from the literature that analysed the main issues of falling film evaporation of refrigerants, to better understand heat transfer and fluid dynamics in such evaporators. First, falling film evaporation is described and compared to pool boiling, to define its main advantages and inconveniences. Then, the literature concerning film around the tubes and between them is analysed, as well as the phenomenon of film breakdown, which sharply deteriorates the heat transfer performance of falling film evaporators. After it, the results from those works that studied analytically and experimentally the heat transfer coefficients (HTCs) with different types of tubes and refrigerants are discussed. The review finishes with a brief summary of important parameters of falling film evaporation, which might be useful for the design of such equipment. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:155 / 171
页数:17
相关论文
共 64 条
[1]  
[Anonymous], HEAT TRANSFER FLUID
[2]  
Armbruster R., 1994, P 10 INT HEAT TRANSF, V3, P275
[3]  
Awad M.M., 2009, P INT WAT TECHN C IW, P1461
[4]  
Awad M.M., 2008, P INT WAT TECHN C IW, P193
[5]   Case study: Limited charge shell and tube ammonia spray evaporator with enhanced tubes [J].
Ayub, Z. H. ;
Chyu, M. -C. ;
Ayub, A. H. .
APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) :1334-1338
[6]   HEAT-TRANSFER IN TURBULENT-FLOW ON A HORIZONTAL TUBE FALLING FILM EVAPORATOR - A THEORETICAL APPROACH [J].
BARBA, D ;
DIFELICE, R .
DESALINATION, 1984, 51 (03) :325-333
[7]   Ozone depletion and global warming: Case for the use of natural refrigerant - a review [J].
Bolaji, B. O. ;
Huan, Z. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 18 :49-54
[8]  
Bressler R., 1958, Z VER DTSCH ING, V100, P630
[9]   Effects of nozzle configuration on a shell-and-tube spray evaporator with liquid catcher [J].
Chang, TB .
APPLIED THERMAL ENGINEERING, 2006, 26 (8-9) :814-823
[10]   Spray evaporation heat transfer of R-141b on a horizontal tube bundle [J].
Chang, TB ;
Chiou, JS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (08) :1467-1478