Diagnosis of overt disseminated intravascular coagulation in critically Ill adults by Sonoclot coagulation analysis

被引:15
作者
Wan, Peng [1 ]
Tong, Hua-Sheng [2 ]
Zhang, Xing-Qin [2 ]
Duan, Peng-Kai [2 ]
Tang, You-Qing [2 ]
Su, Lei [2 ]
机构
[1] Southern Med Univ, Guangzhou 510515, Guangdong, Peoples R China
[2] Gen Hosp Guangzhou Mil Command, Dept ICU, Key Lab Trop Zone Trauma Care & Tissue Repair PLA, Guangzhou 510010, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Coagulation; Platelet function; Disseminated intravascular coagulation; Initial diagnosis; International Society on Thrombosis and Hemostasis score; PROSPECTIVE VALIDATION; INTERNATIONAL SOCIETY; CARDIAC-SURGERY; SCORING SYSTEM; THROMBOELASTOMETRY; THROMBELASTOGRAPHY; MANAGEMENT; ACTIVATION; THROMBOSIS; CRITERIA;
D O I
10.1007/s12185-014-1601-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Disseminated intravascular coagulation (DIC) diagnosis is hampered by the limited availability of reliable clinical or laboratory tests. Currently available tests are time consuming and expensive. We investigated whether coagulation and platelet function analyses using the Sonoclot system were suitable for overt DIC diagnosis in critically ill adults. This was an observational diagnostic study performed in 498 patients presenting with an underlying disorder associated with DIC. Overt DIC patients were identified according to an International Society on Thrombosis and Hemostasis (ISTH) score of > 5. Coagulation and platelet parameters were analyzed using the Sonoclot system, and compared with ISTH as the gold standard. Receiver operating characteristic curves and area under the curves were used to evaluate the value of the Sonoclot parameters. There were no differences for age or gender between the groups. Significant correlations were observed between activated clotting time (ACT) and ISTH score (r = 0.7; P < 0.001), clot rate (CR) and ISTH score (r = 0.5; P < 0.001), platelet function (PF) and ISTH score (r = -0.6; P < 0.001), and PF and platelet count (r = 0.5; P < 0.001). An ACT cut-off value of 213.5 s alone or combined with CR presented good sensitivity (76.7 and 86.8 %, respectively) and specificity (96.2 and 93.3 %, respectively). Sonoclot analysis can be performed using a point-of-care device that effectively discriminates low and high ISTH scores, and that effectively predicts coagulation dysfunction in patients with overt DIC.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 30 条
[1]   Sonoclot evaluation of whole blood coagulation in healthy adult dogs [J].
Babski, Danielle M. ;
Brainard, Benjamin M. ;
Krimer, Paula M. ;
Ralph, Alan G. ;
Pittman, Jennifer R. ;
Koenig, Amie .
JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2012, 22 (06) :646-652
[2]   Prospective validation of the International Society of Thrombosis and Haemostasis scoring system for disseminated intravascular coagulation [J].
Bakhtiari, K ;
Meijers, JCM ;
de Jonge, E ;
Levi, M .
CRITICAL CARE MEDICINE, 2004, 32 (12) :2416-2421
[3]   Effects on coagulation of balanced (130/0.42) and non-balanced (130/0.4) hydroxyethyl starch or gelatin compared with balanced Ringer's solution: an in vitro study using two different viscoelastic coagulation tests ROTEM™ and SONOCLOT™ [J].
Casutt, M. ;
Kristoffy, A. ;
Schuepfer, G. ;
Spahn, D. R. ;
Konrad, C. .
BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (03) :273-281
[4]  
Dalainas I, 2008, EUR REV MED PHARMACO, V12, P19
[5]   Thromboelastometry for the assessment of coagulation abnormalities in early and established adult sepsis: a prospective cohort study [J].
Daudel, Fritz ;
Kessler, Ulf ;
Folly, Helene ;
Lienert, Jasmin S. ;
Takala, Jukka ;
Jakob, Stephan M. .
CRITICAL CARE, 2009, 13 (02)
[6]   Mechanisms of disease:: Platelet activation and atherothrombosis [J].
Davi, Giovanni ;
Patrono, Carlo .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (24) :2482-2494
[7]   Laboratory Testing in Disseminated Intravascular Coagulation [J].
Favaloro, Emmanuel J. .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2010, 36 (04) :458-467
[8]  
Ferasatkish R, 2007, ARCH IRAN MED, V10, P404
[9]   A multicenter, prospective validation of disseminated intravascular coagulation diagnostic criteria for critically ill patients: Comparing current criteria [J].
Gando, S ;
Iba, T ;
Eguchi, Y ;
Ohtomo, Y ;
Okamoto, K ;
Koseki, K ;
Mayumi, T ;
Murata, A ;
Ikeda, T ;
Ishikura, H ;
Ueyama, M ;
Ogura, H ;
Kushimoto, S ;
Saitoh, D ;
Endo, S ;
Shimazaki, S .
CRITICAL CARE MEDICINE, 2006, 34 (03) :625-631
[10]   Coagulation monitoring: Current techniques and clinical use of viscoelastic point-of-care coagulation devices [J].
Ganter, Michael T. ;
Hofer, Christoph K. .
ANESTHESIA AND ANALGESIA, 2008, 106 (05) :1366-1375