Effects of characteristic parameters on heat transfer enhancement of repeated ring-type ribs in circular tubes

被引:14
作者
Huang, Wen-Chieh [1 ]
Chen, Cheng-An [1 ]
Shen, Chi [1 ]
San, Jung-Yang [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Mech Engn, Taichung 40227, Taiwan
关键词
Heat transfer enhancement; Nusselt number; Darcy friction factor; Prandtl number; Performance index; TWISTED-TAPE INSERTS; CORRUGATED TUBES; FRICTION FACTOR; HORIZONTAL TUBES; TRANSVERSE RIBS; TURBULENT-FLOW; PRESSURE-DROP; AUGMENTATION; CONDENSATION; ROUGHNESS;
D O I
10.1016/j.expthermflusci.2015.06.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat transfer enhancement of repeated ring-type ribs in circular tubes was experimentally investigated. Air, water and ethylene glycol-water solution (33.3% EG by vol.) were used as the working fluids. The rib height-to-tube inner diameter ratio (e/d) and rib pitch-to-tube inner diameter ratio (p/d) were arranged in the range of 0.025-0.069 and 0.29-5.8 respectively. The Reynolds number (Re) was in the range of 3601 -26025 and the Prandtl number (Pr) was in the range of 0.7 -15.6. Empirical equations for the Nusselt number (Nu) and Darcy friction factor (f) are proposed. The Nu value increases with the e/d value and it decreases with an increase of the p/d value. In addition, the Nu value increases with the Re value and it is proportional to the 0.45 power of the Pr value. The Nu enhancement index and mechanical energy consumption index were used to compare the heat transfer enhancing tubes to a smooth tube. At e/d <= 0.043, for achieving an effective heat transfer enhancement, the p/d value needs to be smaller than 4.35; at e/d >= 0.069, for avoiding a large pressure drop, the p/d value should be larger than 1.45. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:371 / 380
页数:10
相关论文
共 37 条
[1]  
[Anonymous], 2011, THERM PROP BRIN MOD
[2]   Heat transfer enhancement in a tube with twisted tape inserts placed separately from the tube wall [J].
Bas, Halit ;
Ozceyhan, Veysel .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 41 :51-58
[3]  
Bergles A.E., 1998, HEAT EXCHANGER DES 1
[4]  
Bergles AE, 1981, HEAT EXCHANGERS THER
[5]   Experimental investigation of convective heat transfer and friction factor of Al2o3/water nanofluid in helically corrugated tube [J].
Darzi, Ahmad Ali Rabienataj ;
Farhadi, Mousa ;
Sedighi, Kurosh .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 57 :188-199
[6]   HEAT-TRANSFER ENHANCEMENT BY MEANS OF FLAG-TYPE INSERT IN TUBES [J].
FERNANDEZ, JL ;
POULTER, R .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1987, 30 (12) :2603-2609
[7]   The influence of artificial roughness shape on heat transfer enhancement: Corrugated tubes, dimpled tubes and wire coils [J].
Garcia, A. ;
Solano, J. P. ;
Vicente, P. G. ;
Viedma, A. .
APPLIED THERMAL ENGINEERING, 2012, 35 :196-201
[8]   FORCED-CONVECTION HEAT-TRANSFER IN HELICALLY RIB-ROUGHENED TUBES [J].
GEE, DL ;
WEBB, RL .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1980, 23 (08) :1127-1136
[9]   Condensation heat transfer of R410A inside internally grooved horizontal tubes [J].
Goto, M ;
Inoue, N ;
Yonemoto, R .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (04) :410-416
[10]   Condensation and evaporation heat transfer of R410A inside internally grooved horizontal tubes [J].
Goto, M ;
Inoue, N ;
Ishiwatari, N .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (07) :628-638