Impact of roof geometry of an isolated leeward sawtooth roof building on cross-ventilation: Straight, concave, hybrid or convex?

被引:52
作者
Peren, J. I. [1 ,2 ]
van Hooff, T. [3 ]
Ramponi, R. [4 ]
Blocken, B. [2 ,3 ]
Leite, B. C. C. [1 ]
机构
[1] Univ Sao Paulo, Polytech Sch, Civil Construct Engn Dept, Sao Paulo, Brazil
[2] Eindhoven Univ Technol, Bldg Phys & Serv, NL-5600 MB Eindhoven, Netherlands
[3] Leuven Univ, Bldg Phys Sect, Leuven, Belgium
[4] Politecn Milan, Construct Engn Dept, Built Environm, Architecture, I-20133 Milan, Italy
基金
比利时弗兰德研究基金会;
关键词
Computational Fluid Dynamics (CFD); Building geometry; Natural ventilation; Leeward sawtooth roof geometry; Upward cross-ventilation; ATMOSPHERIC BOUNDARY-LAYER; WIND PRESSURE COEFFICIENTS; CFD SIMULATION; NATURAL VENTILATION; COMFORT;
D O I
10.1016/j.jweia.2015.05.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The roof geometry of a leeward sawtooth roof building can have a large influence on the cross-ventilation flow. In this paper, five different leeward sawtooth roof geometries are evaluated using Computational Fluid Dynamics (CFD). The 3D CFD simulations are performed using the steady Reynolds-Averaged Navier-Stokes approach with the SST k-omega turbulence model to provide closure to the governing equations. The computational grid is based on a grid-sensitivity analysis and the computational model is successfully validated using PIV measurements for a generic isolated building from literature. The five different roof geometries that are studied include one straight and four curved roofs. The curved roofs can be subdivided in one concave, one hybrid (convex-concave) and two convex roof geometries. It is shown that a straight or convex roof geometry can maximize the underpressure in the wake of the building, where the outlet opening is located, which results in enhanced wind-driven cross-ventilation flow. Analysis of the results shows that for a normal wind incidence angle (0 degrees) the straight and convex leeward sawtooth roof geometries can result in an increase of the volume flow rate by 13.0%, 12.5% and 12.3% respectively compared to a concave roof geometry. Furthermore, the increase of the indoor air velocity can be as high as 90% in the upper part of the occupied zone (at h=1.7 m above ground level) for convex versus concave roofs. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:102 / 114
页数:13
相关论文
共 39 条
[1]  
[Anonymous], 1975, International Standard ISO 2533:1975
[2]  
[Anonymous], ISO 7730:2005(E)
[3]  
ANSYS, 2009, FLUENT 12 US GUID
[4]  
Bittencourt L.S, 2006, INTRO VENTILACAO NAT
[5]   CFD simulation for pedestrian wind comfort and wind safety in urban areas: General decision framework and case study for the Eindhoven University campus [J].
Blocken, B. ;
Janssen, W. D. ;
van Hooff, T. .
ENVIRONMENTAL MODELLING & SOFTWARE, 2012, 30 :15-34
[6]   CFD evaluation of wind speed conditions in passages between parallel buildings - effect of wall-function roughness modifications for the atmospheric boundary layer flow [J].
Blocken, Bert ;
Carmeliet, Jan ;
Stathopoulos, Ted .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2007, 95 (9-11) :941-962
[7]   CFD simulation of the atmospheric boundary layer: wall function problems [J].
Blocken, Bert ;
Stathopoulos, Ted ;
Carmeliet, Jan .
ATMOSPHERIC ENVIRONMENT, 2007, 41 (02) :238-252
[10]  
Cebeci T., 1977, Momentum Transfer in Boundary Layers