A Real Time Measurement Method of Leakage Conductance in Distribution Network

被引:0
|
作者
Fan Yuefu [1 ]
Chen Lei [2 ]
Li Jianhua [1 ]
Liu Fang [1 ]
Yu Kun [2 ]
Guo Xiaojing [1 ]
Zeng Xiangjun [2 ]
Liu Kai [1 ]
Liu Ran [1 ]
机构
[1] State Grid Luoyang Power Supply Co, Luoyang 471023, Peoples R China
[2] Changsha Univ Sci & Technol, Hunan Prov Key Lab Smart Grids Operat & Control, Changsha 410114, Hunan, Peoples R China
来源
2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) | 2018年
基金
中国国家自然科学基金;
关键词
Damping resistor; ground leakage conductance; resonant grounded distribution network; zero-sequence voltage;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the full current compensation arc suppression coil in the distribution network, the application range is gradually expanded, the requirements for the accuracy of the line-to-ground leakage conductance measurement also increase. To suppress or eliminate the ferromagnetic resonance overvoltage caused by the saturation of the voltage transformer, a damping resistor is usually installed on the triangular side of the secondary opening of the voltage transformer or on the side of the neutral point in practical applications. The paper considers that the neutral point is grounded by the series damping resistor of the arc suppression coil, a method for real-time measurement of ground leakage conductance in a resonant grounding distribution network is proposed. The non-power frequency specific frequency current signal is injected into the distribution network through the zero-sequence voltage transformer of the distribution network, and the signal injection unit is equivalent to the current source. The voltage signal measured by the voltage transformer inside the arc suppression coil. According to the relationship between the injected characteristic current and the return characteristic voltage, the leakage conductance of the distribution network to the ground is calculated. In the PSCAD/EMTDC simulation environment, the proposed real-time measurement method for ground leakage conductance is simulated and analyzed. The measurement method has high measurement accuracy was shown. And it can eliminate the influence of the internal impedance of the voltage transformer and the addition of the damping resistance, the measurement process is safe and simple.
引用
收藏
页码:3748 / 3753
页数:6
相关论文
共 50 条
  • [1] Water leakage reduction in the water distribution network with real time pressure management
    Kosucu M.M.
    Sari O.
    Demirel M.C.
    Kiran S.
    Yilmaz A.
    Aybakan A.
    Albay E.
    Ozgur Kirca V.S.
    2021, Turkish Chamber of Civil Engineers (32): : 10541 - 10564
  • [2] Water Leakage Reduction in the Water Distribution Network with Real Time Pressure Management
    Kosucu, Mehmet Melih
    Sari, Omer
    Demirel, Mehmet Cuneyd
    Kiran, Samet
    Yilmaz, Abdurrahman
    Aybakan, Abdulbaki
    Albay, Enes
    Kirca, V. S. Ozgur
    TEKNIK DERGI, 2021, 32 (01): : 10541 - 10564
  • [3] Leakage detection in a real distribution network using a SOM
    Aksela, K.
    Aksela, M.
    Vahala, R.
    URBAN WATER JOURNAL, 2009, 6 (04) : 279 - 289
  • [4] A Real-Time Method to Detect the Leakage Location in Urban Water Distribution Networks
    Ma, Xiaoyu
    Li, Yalin
    Zhang, Weiping
    Li, Xiujuan
    Shi, Zhiman
    Yu, Junfeng
    Wang, Jiangxia
    Liu, Jingqing
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2022, 148 (12)
  • [5] Real-Time Control of Pressure for Leakage Reduction in Water Distribution Network: Field Experiments
    Fontana, N.
    Giugni, M.
    Glielmo, L.
    Marini, G.
    Zollo, R.
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2018, 144 (03)
  • [6] Calibration and Optimal Leakage Management for a Real Water Distribution Network
    Nicolini, Matteo
    Giacomello, Carlo
    Deb, Kalyanmoy
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 2011, 137 (01): : 134 - 142
  • [7] Accurate Measurement of Leakage Current in Distribution Network by Injected Signal
    Zhu Siguo
    Chen Lei
    Yu Kun
    Zeng Xiangjun
    Tan Yanjun
    Huang Qingjun
    Zhu Yuan
    Mao Xinguo
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 1682 - 1685
  • [8] Real time leakage detection network in hazardous waster impoundanents
    Yang, P
    Neng, CX
    Sun, J
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 4, 2005, : 432 - 435
  • [9] USE OF SIMULATED HOLIDAYS FOR THE EVALUATION OF THE METHOD FOR LEAKAGE CONDUCTANCE MEASUREMENT ON UNDERGROUND AND SUBMERGED PIPELINES
    MATSUSHIMA, I
    NUNOMURA, K
    MATERIALS PERFORMANCE, 1979, 18 (02) : 60 - 64
  • [10] Model calibration and leakage assessment applied to a real Water Distribution Network
    Roma, Josep
    Perez, Ramon
    Sanz, Gerard
    Grau, Sergi
    COMPUTING AND CONTROL FOR THE WATER INDUSTRY (CCWI2015): SHARING THE BEST PRACTICE IN WATER MANAGEMENT, 2015, 119 : 603 - 612