Correction for FDG PET dose extravasations: Monte Carlo validation and quantitative evaluation of patient studies

被引:30
作者
Silva-Rodriguez, Jesus [1 ,2 ,3 ]
Aguiar, Pablo [1 ,2 ,3 ]
Sanchez, Manuel [4 ]
Mosquera, Javier [4 ]
Luna-Vega, Victor [4 ]
Cortes, Julia [2 ,3 ]
Garrido, Miguel [2 ,3 ]
Pombar, Miguel [4 ]
Ruibal, Alvaro [2 ,3 ,5 ]
机构
[1] Fdn Ramon Dominguez, Santiago De Compostela, Galicia, Spain
[2] Univ Santiago de Compostela, Complexo Hosp, Serv Med Nucl, Galicia 15782, Spain
[3] Inst Invest Sanitarias IDIS, Grp Imaxe Mol, Santiago De Compostela 15706, Galicia, Spain
[4] Univ Santiago de Compostela, Complexo Hosp, Serv Radiofis & Protecc Radiol, Galicia 15782, Spain
[5] Fdn Tejerina, Madrid 28003, Spain
关键词
PET; SUV; quantification; Monte Carlo Simulation; RESPONSE ASSESSMENT; ROI DEFINITION; UPTAKE VALUES; SUV; ACCURACY; PROTOCOL; CANCER;
D O I
10.1118/1.4870979
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Current procedure guidelines for whole body [18F] fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) state that studies with visible dose extravasations should be rejected for quantification protocols. Our work is focused on the development and validation of methods for estimating extravasated doses in order to correct standard uptake value (SUV) values for this effect in clinical routine. Methods: One thousand three hundred sixty-seven consecutive whole body FDG-PET studies were visually inspected looking for extravasation cases. Two methods for estimating the extravasated dose were proposed and validated in different scenarios using Monte Carlo simulations. All visible extravasations were retrospectively evaluated using a manual ROI based method. In addition, the 50 patients with higher extravasated doses were also evaluated using a threshold-based method. Results: Simulation studies showed that the proposed methods for estimating extravasated doses allow us to compensate the impact of extravasations on SUV values with an error below 5%. The quantitative evaluation of patient studies revealed that paravenous injection is a relatively frequent effect (18%) with a small fraction of patients presenting considerable extravasations ranging from 1% to a maximum of 22% of the injected dose. A criterion based on the extravasated volume and maximum concentration was established in order to identify this fraction of patients that might be corrected for paravenous injection effect. Conclusions: The authors propose the use of a manual ROI based method for estimating the effectively administered FDG dose and then correct SUV quantification in those patients fulfilling the proposed criterion. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:7
相关论文
共 33 条
[1]   A Systematic Review of the Factors Affecting Accuracy of SUV Measurements [J].
Adams, Michael C. ;
Turkington, Timothy G. ;
Wilson, Joshua M. ;
Wong, Terence Z. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (02) :310-320
[2]   Quantitative assessment of FDG uptake in brown fat using standardized uptake value and dual-time-point scanning [J].
Alkhawaldeh, Khaled ;
Alavi, Abass .
CLINICAL NUCLEAR MEDICINE, 2008, 33 (10) :663-667
[3]   Clinical Evaluation of the Iterative Metal Artifact Reduction Algorithm for CT Simulation in Radiotherapy [J].
Axente, M. ;
Lee, K. ;
Paidi, A. ;
Bani-Hashemi, A. ;
Hristov, D. .
MEDICAL PHYSICS, 2013, 40 (06)
[4]   Monte Carlo simulation and scatter correction of the GE advance PET scanner with SimSET and geant4 [J].
Barret, O ;
Carpenter, TA ;
Clark, JC ;
Ansorge, RE ;
Fryer, TD .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :4823-4840
[5]   18F-FDG PET and PET/CT in the Evaluation of Cancer Treatment Response [J].
Ben-Haim, Simona ;
Ell, Peter .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) :88-99
[6]   Variations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users [J].
Beyer, Thomas ;
Czernin, Johannes ;
Freudenberg, Lutz S. .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (02) :303-310
[7]  
Boellaard R, 2004, J NUCL MED, V45, P1519
[8]   Standards for PET Image Acquisition and Quantitative Data Analysis [J].
Boellaard, Ronald .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 :11S-20S
[9]   The Netherlands protocol for standardisation and quantification of FDG whole body PET studies in multi-centre trials [J].
Boellaard, Ronald ;
Oyen, Wim J. G. ;
Hoekstra, Corneline J. ;
Hoekstra, Otto S. ;
Visser, Eric P. ;
Willemsen, Antoon T. ;
Arends, Bertjan ;
Verzijlbergen, Fred J. ;
Zijlstra, Josee ;
Paans, Anne M. ;
Comans, Emile F. I. ;
Pruim, Jan .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (12) :2320-2333
[10]  
Daube-Witherspoon ME, 2002, J NUCL MED, V43, P1398